A.O. Smith QOS1235 Specifcations

®
Commercial Storage Tanks
FACTORY JACKETED AND INSULATED STORAGE TANKS
These A. O. Smith storage tanks are designed for storing potable water. Fitting locations are designed to meet the needs of normal installations plus those for the A. O. Smith Cer-Temp 80® and Shure-Temp™ piping methods.
MODELS
TJ-80S, TJ-80A
TJV-120A, TJV-120M
FEATURES
A. O. Smith storage tanks are ideal for use with gas-fired copper heat exchanger equipment for storage of any potable water at temperatures up to 180°F.
GLASSLINED TANK - Alkaline borosilicate composition permanently fused to steel by firing at a temperature of 1600°F, providing years of corrosion protection and dependable use.
HEAVY GAUGE STEEL JACKET - With baked enamel finish.
THREADED OPENINGS - All tanks furnished with threaded openings for thermometer, relief valve, 2” recirculation lines, tankstat, and drain valve.
INSULATION - Storage Tanks meet or exceed R12.5 minimum thermal insulation requirements of the U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1
TJ-80S, TJ-80A, TJV-120M and TJV-120A
• Fits through 30” door
• Magnesium anode for anti-corrosion protection
TJ-80S
• 80 gallons
• High density foam insulation saves energy, helps reduce standby heat loss
• 160 psi working pressure
TJV-120M
• 119 gallons
• High density foam insulation saves energy, helps reduce standby heat loss
• 160 psi working pressure
OPTIONS
Perfectly balanced manifold kits (120 gallon models) allow installation where 240 to 480 gallons of stored water is required.
TJV-200-M - 175 GALLONS
• 160 psi ASME standard working pressure
• 2” foam insulation
• Handhole cleanout (Standard)
• Fits through 33” door
• Storage is downsized to 175 gallons for a 32” x 77” envelope for space restrictive installations. Model TJV-200 is available with 200 gallons of storage.
• Magnesium anodes for extra corrosion protection
& TJV-200M
120 Gallon Model
TJ-80A
• 80 gallons
• High density foam insulation saves energy, helps reduce standby heat loss
• 160 psi ASME standard working pressure
TJV-120A
• 119 gallons
• High density foam insulation saves energy, helps reduce standby heat loss
• 160 psi ASME standard working pressure
Revised November 2012
Revised September 2010
5 YEAR WARRANTY
If the tank should leak any time during the first 5 years, under the terms of the warranty, A. O. Smith will repair or replace the tank. Installation, labor, handling and local delivery are extra. For complete information, consult the written warranty.
Page 1 of 4
AOSTT35100
®
Commercial Storage Tanks
62"
54 1/4"
42 1/4"
9 3/4"
TJV-120A
28"
2" NPT
1-1/4" NPT
(ANODE)
1" NPT
ASME PLATE
LOCATED UNDER
COVER
2" NPT FRONT
2" NPT FRONT & REAR
17 3/4"
10 3/4"
TJV-120M
2" NPT
3/4" NPT
(ANODE)
29 3/8"
1" NPT
FRONT
2" NPT
FRONT
2" NPT
FRONT
2" NPT
FRONT & REAR
CLEANOUT
15"
11"
4 1/8"
3 1/2"
3/4" NPT
FRONT
61 3/4"
50 1/2"
1" NPT
3/4" NPT
44 1/2"
21 1/4"
TJV-200M
3/4" NPT
(ANODES)
2" NPT
32 "
1" NPT
3/4" NPT
77 "
64"
17 1/4"
12 1/4"
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
2" NPT
ASME PLATE LOCATED UNDER
COVER
17 1/4"
12 1/4"
Revised November 2012
Revised September 2010
www.hotwater.com
Page 2 of 4