Residential Gas Water Heaters
POWER DIRECT-VENT
PROMAX ®SL POWER DIRECT-VENT FEATURES
POWER DIRECT-VENT DESIGN
ProMax SL Power Direct Vent residential gas models are equipped with FVIR
technology to meet Phase III of the ANSI Z21.10.1 standards for the resistance to
flammable vapor ignition and resistance to lint, dust and oil accumulation tests.
The Closed-combustion two-pipe system draws combustion air from outside
and vents outside the home. The system uses PVC, CPVC or ABS pipe and vents
up to 45 feet with 3" pipe, including one elbow.
SIDE-MOUNTED RECIRCULATING TAPS
For installation with combination space heating/potable water heating
applications (such as the ProMax XL Heat Exchanger) or any system requiring
a recirculating hot water loop.
INTELLI-VENT®GAS CONTROL
Equipped with silicon nitride hot surface igniter and advanced electronics for
precise control of water temperature and simplified system diagnostics.
HEA T TRAP NIPPLES
Standard on all models.
QUIET MODULAR BLOWER
With 110/120 Volt electrical system (rating 3 amps or less), with 6-foot cord, standard
3-prong male connector.
A. O. SMITH DYNACLEAN™DIFFUSER DIP TUBE
Reduces lime and sediment buildup, maximizes hot water output. Made from long-lasting PEX
cross-link polymer.
GREEN CHOICE™GAS BURNER
Patented “Eco-Friendly” design reduces NOx emissions by up to 33%, complies with Southern
California and Texas requirements.
MAGNESIUM ANODE RODS
Provides long-lasting protection against tank corrosion.
DURABLE T AMPER-RESISTANT BRASS DRAIN V ALVE
A. O. SMITH PERMAGLAS
Protects steel tank from rust.
FACTOR Y-INSTALLED TEMPERATURE & PRESSURE (T&P) RELIEF VALVE
CODE COMPLIANCE: U.B.C., S.B.C.C., C.A.B.O., H.U.D., B.O.C.A. NA TIONAL
CODES, ASHRAE/IES 90.1-1999 AND 2004 NAECA
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANS Z21.10.1 standards governing storage-type water heater.
6-YEAR LIMITED T ANK AND PARTS W ARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
®
GLASS COA TING
* Intelli-Vent®is a registered trademark of the Emerson Electric Company
www.hotwater.com
Revised August 2007R
ARGSS00407
L.1
RESIDENTIAL
POWER DIRECT-VENT
Gas Water Heaters
FIRST
ENERGY
FACTOR
.60
.58
.58
GALLON
CAPACITY
MODEL
NUMBER
GPD-40L 73 .59 40 40,000 † 30,000 † 41 16 57 48-1/2 21 15 8 42 17 42 224
GPDX-50L 80 .58 50 65,000 † 47,500 † 64 16 69-1/2 61 21 15 8 54-1/2 17 54-1/2 232
GPD-75L 123 .53 75 70,000 † 53,200 † 72 16 71-1/2 61-1/2 26-1/4 15-1/2 8 54-1/2 17 54-1/2 352
GPDX-50L is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
GPD-75L is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
Recovery capacity based on actual performance tests.
Water Connections – 3/4" Male on all models.
† Propane Gas – 40-Gallon: 36,000 BTU input, 27,360 BTU output.
HOUR
RATING PER HOUR PER HOUR GALLONS
GALLONS NATURAL NATURAL PER HOUR (LBS.)
70
105
130
50-Gallon: 60,000 BTU input, 43,800 BTU output.
75-Gallon: 65,000 BTU input, 49,400 BTU output.
BTU BTU RECOVERY
INPUT OUTPUT 90ºF RISE
R
VALUE
DIMENSIONS IN INCHES APPROX.
SHIPPING
ABCDE FGH
C
E
IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS
Read and follow requirements shown in the Installation Manual for ProMax®Power
Direct-Vent Gas water heaters dealing with type, placement and length of vent pipe
and vent termination, as well as clearances required to provide adequate
combustion and proper ventilation.
4"
OPTIONAL CIRCULATING LOOP CONNECTION ASSEMBLIES
Sold separately. Kit Number 900152-2 includes two extended PEX lined nipples for side
port connections. Kit Number 900260-4 is same as 900152-2, plus two
di-electric unions and 2 brass isolation valves. For use with systems that have a check
valve in the air handler or recirculating lines.
11.5" MIN.
FROM TOP OF
HEATER TO
CENTER LINE
OF FLUE
3" VENT
WEIGHT
IMPORTANT :
SEE INST ALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER
HEA TERS
1/2" GAS
OPTIONAL (DELUXE) ROUND HORIZONT AL
CONNECTION
VENT TERMINA TION KIT
Part Number 9002749
OPTIONAL (DELUXE) SQUARE HORIZONT AL
VENT TERMINA TION KIT
Part Number 9003328
D
Maximum hydrostatic working pressure: 150 psi
For Technical Information and Automated Fax Service, call 800-527-1953.
500 Tennessee Waltz Parkway, Ashland City, TN 37015
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
www.hotwater.com
Revised August 2007R ©2007 A. O. Smith Corporation Printed in U.S.A.