Commercial Electric
Water Heaters
LIGHT-SERVICE COMMERCIAL ELECTRIC WATER HEATERS
Designed for light duty commercial applications with intermittent hot water loads.
GLASSLINED TANK
• Tank interior is coated with glass
specially designed by A. O. Smith for
water heater use.
HEATING ELEMENTS
• Two 4.5 KW zinc plated copper
sheathed elements are standard.
STANDARD VOLTAGES
• The standard voltage is 240V single
phase.
TOP MOUNTED RECESSED
JUNCTION BOX
CONTROLS
• Thermostat is adjustable through a
range of 120º to 181ºF with a manual
reset high temperature cutoff. The
heater is wired for non-simultaneous
single phase operation.
™
COREGARD
ANODE ROD
MAXIMUM WORKING PRESSURE
150 PSI
FACTORY INSTALLED CSA
CERTIFIED AND ASME RATED
TEMPERATURE AND PRESSURE
RELIEF VALVE
CERTIFIED TO UL 1453 FOR
COMMERCIAL ELECTRIC WATER
HEATERS
COMPLIANCE
• Meets the standby loss requirements
of the U.S. Department of Energy and
current edition of ASHRAE/IES 90.1.
WARRANTY
• 3-Year limited tank/1-Year limited
parts.
• For complete information consult the
written warranty or hotwater.com.
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection
for longer than standard anode rods.
ENHANCED-FLOW BRASS DRAIN
VALVE
• Solid brass, tamper resistant,
enhanced-flow, ball type, drain valve.
© March 2016 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2
AOSCE15701
VALV E
ACCESS
PANEL
Commercial Electric
Water Heaters
ANODE
JUNCTION
BOX
ACCESS
PANEL
DRAIN
VALV E
T&P VALV
PRODUCT SPECIFICATIONS
Model Number
LTE 66D 66 4500 60-1/4 53 22 8 146
LTE 80D 80 4500 60-1/2 52-1/4 24 8 175
LTE 120D 119 4500 61-1/2 54-1/2 28 8 268
Not available with top mounted T&P valve option.
Inlet and outlet connections: 3/4”
Gallon
Capacity
Standard Element
Wattage 240 VAC
A B
Dimensions in Inches
Diameter
C
D
Approx. Shipping
Weight (lbs)
RECOVERY CAPACITIES
Element Wattage
(Upper/Lower)
Non-Simultaneous
3000/3000 3
3500/3500 3.5
4000/4000 4
4500/4500 4.5
5000/5000 5
5500/5500* 5.5
Simultaneous
3000/3000 6
3500/3500 7
4000/4000 8
4500/4500 9
5000/5000 10
5500/5500* 11
Available in 208 and 240 volts only. Voltage and wattage must be specified when ordering.
Standard factory wiring is for non-simultaneous operation. Simultaneous operation is optional.
* 5500 Watts not available in 208 Volts
Input
kW
°F 36 40 54 60 72 80 90 100 108 120 126 °F
°C 20 22.2 30 33.3 40 44.4 50 55.5 60 66.6 70 °C
GPH 34 30 23 20 17 15 14 12 11 10 10 GPH
LPH 128 115 85 77 64 58 51 46 43 38 37 LPH
GPH 40 36 27 24 20 18 16 14 13 12 11 GPH
LPH 151 136 101 91 75 68 60 54 50 45 43 LPH
GPH 45 41 30 27 23 20 18 16 15 14 13 GPH
LPH 170 153 114 102 85 77 68 61 57 51 49 LPH
GPH 51 46 34 30 25 23 20 18 17 15 14 GPH
LPH 192 173 128 115 96 86 77 69 64 58 55 LPH
GPH 56 51 38 34 28 25 23 20 19 17 16 GPH
LPH 213 192 142 128 107 96 85 77 71 64 61 LPH
GPH 63 56 42 38 31 28 25 23 21 19 18 GPH
LPH 237 213 158 142 119 107 95 85 79 71 68 LPH
GPH 68 61 46 41 34 30 27 24 23 20 19 GPH
LPH 256 230 107 151 128 115 103 92 85 77 73 LPH
GPH 80 72 53 48 40 36 32 29 27 24 23 GPH
LPH 302 272 201 181 151 136 121 109 101 91 86 LPH
GPH 90 81 60 54 45 41 36 32 30 27 26 GPH
LPH 341 307 227 205 170 153 136 123 114 102 97 LPH
GPH 101 91 68 61 51 46 41 36 34 30 29 GPH
LPH 384 345 256 230 192 173 153 138 128 115 110 LPH
GPH 113 101 75 68 57 51 45 41 38 34 32 GPH
LPH 426 384 284 256 213 192 170 153 142 128 122 LPH
GPH 125 113 84 75 63 56 50 45 42 38 36 GPH
LPH 474 427 316 285 237 213 190 171 158 142 135 LPH
U.S. Gallons/Hour and Liters/Hour at Indicated Temperature Rise
SPECIFICATION
The water heaters(s) shall be model(s) No. ______ as manufactured by A. O. Smith or an approved equal. Heater(s) shall be rated at _____kW, _____volts, single-phase, 60 cycle AC,
and listed by Underwriters’ Laboratories. Models shall meet the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IES 90.1. Tank(s) shall be
_____gallon capacity. Heater(s) shall have 150 psi working pressure and be equipped with an extruded high density anode rod. All internal surfaces of the heater(s) exposed to water
shall be glasslined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range of 1400°F to 1600°F. Electric heating elements shall be zinc
plated copper sheath. Each element shall be controlled by an individually mounted thermostat and high temperature cutoff switch. The outer jacket shall be of baked enamel finish and
shall enclose the tank with foam insulation. The drain valve shall be located in the front for ease of servicing. Heater tank shall have a three year limited warranty as outlined in the
written warranty. Fully illustrated instruction manual to be included.
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
© March 2016 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA
Page 2 of 2
AOSCE15701