90% EFFICIENT, LOW-NOx HYDRONIC HEATING BOILERS
The Legend 2000® series delivers an exceptional 90% thermal efficiency by combining advanced pre-mix burner design and an extruded, self-baffling copper heat exchanger for outstanding efficiency and unsurpassed performance. The heat-exchanger design exposes more surface area to the combustion system to maximize heat transfer. Each model features a small footprint with zero side clearance for outstanding adaptability perfect for retrofits. The exclusive Dia-Scan® solid-state self-diagnostic system helps make operation and troubleshooting quick and easy.
ADVANCED HIGH-EFFICIENCY, LOW-NOx COMBUSTION TECHNOLOGY
• Advanced burner design precisely pre-mixes gas and air before ignition, increasing combustion efficiency and reducing emissions
• Delivers optimum burner performance for 90% thermal efficiency
• Meets or exceeds Texas and California SCAQMD Rule 1146.2 air quality standards differential, loop temperature and fault codes
NEW STAINLESS STEEL BURNER DESIGN
• Features metal fiber alloy sheath for consistent heat distribution and reliable performance under all conditions
DIA-SCAN BOILER CONTROL
• Comprehensive display panel includes LEDs with readouts for current operating and fault status
• Precise temperature management of ± 1º F
• Self-diagnostics eliminate guess work and pinpoints problems— trouble shooting has never been easier
EXCLUSIVE NO-BAFFLE HEAT EXCHANGER DESIGN
• Extruded copper manufacturing process exposes more surface area to the combustion system for increased heat-transfer efficiency
• Unique self-baffling design (patent pending) is a significant improvement over traditional heat-transfer systems
100% ALL NON-FERROUS WATERWAYS
• All waterways 100% copper, brass or bronze for years of reliable performance
• Impervious to thermal shock
GASKETLESS ASME HEAT EXCHANGER
• Superior design assures reliability and long-life performance
• Isolated location offers optimum protection and years of service
OPTIONAL FACTORY MOUNTED AND WIRED PUMP AVAILABLE
• Integral boiler mounted all bronze pump for primary/secondary pumping systems
• Allows for 50 equivalent feet of pipe between boiler and primary loop
COMPACT, LOW-PROFILE DESIGN
• Allows easy entry for modular installations
• Zero clearance on sides for maximum installation versatility
CATEGORY IV LISTED
• Legend 2000® boilers utilize a mechanical forced draft system designed to prevent leakage of flue (vent) gases and condensate
MEETS OR EXCEEDS ASHRAE/IESNA 90.1-1999
TEN-YEAR HEAT EXCHANGER LIMITED WARRANTY
For complete information, consult written warranty or contact A. O. Smith
September 2006
LB-500
through
LB-1000
ASME
Page 1 of 4
ACMSS00805
®
®
90% EFFICIENT, LOW-NOx HYDRONIC HEATING BOILERS
CATEGORY IV LISTED
• Legend 2000® hot water supply boilers utilize a mechanical forced draft system designed to prevent leakage of flue (vent) gases and condensate
PROFESSIONAL START-UP SERVICE FURNISHED
• Assures optimum performance for each installation
MEETS ASHRAE/IESNA 90.1-1999
• For complete information, consult written warranty or contact A. O. Smith
OTHER LEGEND 2000
®
FEATURES:
ASME 160# W.P. ASME PRESSURE RELIEF VALVE #50 FLOW SWITCH MOUNTED BRASS DRAIN VALVE LOW GAS PRESSURE SWITCH LOW AIR PRESSURE SWITCH DIGITAL THERMOMETERS MANUAL RESET HI LIMIT
LEGEND 2000
®
OPTIONS:
CODE OPTIONS: CSD-1 I.R.I. CODEILLINOIS CODENEW YORK CODECALIFORNIA CODELOW WATER CUTOFFDRY CONTACTS FOR ANY
BOILER FAILURE
ALARM BELLINTEGRAL BOILER MOUNTED PUMP
FOR PRIMARY/SECONDARY PUMPING SYSTEMS
SEQUENCING PANELTHROUGH-THE-WALL VENTING DIRECT/SEALED VENT KITSKID-MOUNTED SYSTEMS
LEGEND 2000
®
VENTING VERSATILITY
STANDARD-VENT OR DIRECT-VENT FLEXIBILITY
• Standard-venting, vertical or horizontal sidewall
–Single pipe vent runs up to 180 equivalent feet (90° elbow = 10 equivalent feet, 45° elbow or boot tee = 5 equivalent feet)
• Two-pipe direct-venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building
• Air intake and exhaust vent runs permitted up to 90 equivalent feet (90° elbow = 10 equivalent feet, 45° elbow or boot tee = 5 equivalent feet)
Please consult latest edition of the Installation Manual for detail venting information and maximum/minimum venting distances.
Page 2 of 4
ACMSS00805
Loading...
+ 2 hidden pages