DIRECT VENT
Residential Gas
Water Heaters
DIRECT VENT DESIGN
• One-pipe, dual-channel closed system
draws all make-up air from outside the
home, eliminating problems caused by
insufficient indoor ventilation and is
FVIR compliant. Horizontal air intake and
venting on all models up to 80 inches
from outside wall with no electrical
power needed.
INTELLIGENT CONTROL LOGIC
• The internal microprocessor provides
enhanced operating parameters and
tighter differentials for precise sensing
and faster heating response to optimize
performance.
• Uses a themopile to generate the power
needed to operate the electronic gas
control without requiring an external
power source.
• The electronic gas control incorporates
an LED status indicator that monitors
system operation and service
diagnostics.
GREEN CHOICE® GAS BURNER
• Patented eco-friendly design reduces
NOx emissions up to 33% and complies
with low emissions of less than 40 ng/J.
DYNACLEAN™ DIFFUSER DIP TUBE
• Helps reduce lime and sediment buildup
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
COREGARD™ ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
PUSH BUTTON PIEZO IGNITOR
• Makes lighting pilot fast and easy with
one hand push button spark ignition.
HEAT TRAP NIPPLES
• Factory-installed for faster installation
ENHANCED-FLOW BRASS DRAIN
VALVE
• Our residential water heaters have a
solid brass, tamper resistant, enhancedflow, ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a ¼ turn (open/close) radius,
which not only permits full straightthrough water flow but also a quick and
positive shut off.
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
CODE COMPLIANCE
• Meets UBC, CEC and HUD National
Codes.
• Meets the thermal efficiency and
standby loss requirements of the U.S.
Department of Energy and current
edition of ASHRAE/IESNA 90.1
• Complies with the Federal Energy
Conservation Standards effective April
16, 2015, in accordance with the Energy
Policy and Conservation Act (EPCA), as
amended.
DESIGN-LISTED BY CSA
INTERNATIONAL
• Certified at 300 PSI test pressure
and 150 PSI working pressure. Listed
according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type
gas water heaters.
6-YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult
written warranty or go to hotwater.com.
©2015 A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2
AOSSRG45702
Residential Gas
Water Heaters
Model
Number
GDV-40 40 72 0.63 38,000 41 64 49-3/4 22 13-1/4 15-1/4 42-1/2 29 15-1/4 Co-Axial 178
GDV-50 50 91 0.62 40,000 43 73 59 22 13-1/4 15-1/4 51-3/4 29 15-1/4 Co-Axial 200
GDVT-50 50 92 0.61 47,000 51 74 60 22 13-1/4 15-1/4 52-3/4 29 15-1/4 Co-Axial 215
Dual-channel system has 3” vent pipe inside 6” air intake pipe, for the 40 and 50-gallon models.
All models have 2” foam cavity.
Water connection is 3/4” male on 8” center.
*Allow 29” for front to back dimension for gas control and air intake pipe at the rear of the heater.
No option available for top T&P.
Gallon
Capacity
First Hour
Rating
Gallon
Energy
Factor
Input BTU
Per Hour
Recovery
9OºF Rise
Gallon Per
Hour
A B C D E F *G H
All models are available in propane (LP) gas (series 301).
All models are certified from sea level to 7,700 ft. elevation.
All models available with side connections. Add “L” to the model number, example GDV-40L
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Dimensions in Inches
Vent
Outlet
Approx.
Shipping
Weight (lbs)
IMPORTANT! VENT INSTALLATION AND
TERMINATION REQUIREMENTS
• Maximum horizontal vent distance is 80” to the outside
of exterior wall.
• Maximum vertical vent distance is 72” above heater
before 90 degree turn through exterior wall.
• Minimum horizontal vent distance is 17” to outside of
exterior wall.
• Vent pipes may be trimmed (cut) for short vent
installations.
• The recommended installation height for the vent
termination is dimension “A” in the above table. The
minimum allowable height (center line of termination
opening) is 60 ¾” for the 40-gallon model, 69 ½” for
21º
the 50-gallon 40,000 BTU input model, 70 ½” for the
50-gallon model, 47,000 BTU input model.
VENT RESTRICTOR PLATE:
• The vent restrictor plate is required for short horizontal
MINIMUM VENT
17”
MAXIMUM VENT
80”
vent runs less than 30” horizontal and for vent runs
6” DIA. ON 40 & 50 GAL. MODELS
when the termination’s height is greater than 48”
above the heater. The only time the restrictor is not
required is for horizontal runs greater than 30” in
length with the termination less (lower) than 48” above
the heater. See installation instructions for complete
details.
3/4” MALE NPT
OUTLET & INLET
OFFSET VENT ARRANGEMENT:
• The vent run may have one (1) 90 degree horizontal
turn prior to terminating through the exterior wall. See
installation instructions for complete details.
• Vent termination clearance hole through the exterior
wall should be approximately 7” diameter.
• Snow accumulation and drifting should be considered
SIDE TAP AND T&P
A
FRONT
EXTERIOR
WALL
when locating the termination.
• An optional wire grill vent cap protector is available
through the parts department (part number
9006627005).
• See the installation manual for complete installation
and venting requirements.
E
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
www.hotwater.com | 800-527-1953 Toll-Free USA