A.O. Smith ACB-110S-N, ACB-150S-N, ACB-199S-N User Manual

COMMERCIAL-GRADE
PROLINE® XE HIGH EFFICIENCY COMBI BOILERS
COMMERCIAL-GRADE RESIDENTIAL
Ultra-Low NOx combi boiler provides high efficiency space heating and domestic hot water (DHW) in a compact footprint that’s easy to install and maintain.
FEATURES:
95% AFUE
ENERGY STAR® QUALIFIED
AVAILABLE IN NATURAL GAS OR PROPANE (LP)
USER FRIENDLY CONTROLS
• Programming the combi boiler takes less than two minutes and uses plain text rather than number codes.
AIR HANDLER INTERLOCK
• Priority control for DHW
RESIDENTIAL COMBI BOILERS
INDOOR MODELS
UP TO 74% MORE SPACE HEATING CAPACITY THAN COMPETITIVE COMBI BOILERS
MODULATING BURNER WITH 10:1 TURNDOWN
POWER DIRECT VENT DESIGN
• 2” up to 60 equivalent feet on the 110 and 150 models only
• 3” up to 100 equivalent feet on all models
• Flexible venting with PVC (solid core), Polypropylene, CPVC, and stainless steel.
INDUSTRY LEADING DHW DELIVERY UP TO 4.8 GPM @ 77°F RISE
FIRE TUBE HEAT EXCHANGER
• Innovative design increases heat transfer
• Lower pressure drop than water tube designs
MAXIMUM WORKING PRESSURE
• 150 PSI DHW
• 50 PSI Boiler
COMPLIES WITH LEAD FREE STANDARDS
QUICKER DHW RESPONSE
• Advanced control technology prevents the cold water sandwich often found with other combi boilers.
ACCESSORIES
• Low Water Cut-off with Manual Reset and Test
• Neutralizer Kit
• Isolation Valve Kit
• Concentric Termination
• Sidewall Vent Termination
• Product Preservers
• Floor Stand
• Outdoor Temperature Sensor
• Natural Gas to LP Conversion Kit
WARRANTY
• 10-year limited warranty on heat exchanger in residential applications
• 5-year limited warranty on all parts
®
Anti-Scale System
© June 2018 A. O. Smith Corporation. All Rights Reserved
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2
AOSRG45018
COMMERCIAL-GRADE
E
150-199 Models
BOTTOM
FRONT
RESIDENTIAL COMBI BOILERS
Model
Number*
Gas Consumption Input
Minimum
BTU/H
Maximum
BTU/H
AFUE%
Heating
Capacity
BTU/H
Net AHRI
Rating
BTU/H**
Minimum
in. W.C.†
Maximum
in. W.C.
GPM at
77°F Rise
Water Connections
Space
Heating
DHW
Gas
Connection
Approx.
Shipping
Weight (lbs)
Indoor Models ACB-110S-N 11,000 110,000 95.0 102,000 89,000 4.0 14.0 2.6 1” NPT 3/4” NPT 1/2” NPT 139 ACB-150S-N 15,000 150,000 95.0 139,000 121,000 4.0 14.0 3.6 1” NPT 3/4” NPT 1/2” NPT 142 ACB-199S-N 19,999 199,999 95.0 185,000 161,000 4.0 14.0 4.8 1” NPT 3/4” NPT 1/2” NPT 159
*S Models can operate up to 4,500’. For high altitude (3,000’ - 9,600’), change S to H. For liquid propane (LP), change N to P. †For LP, minimum supply pressure is 8.0 in. W.C. **The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. The ratings have been determined under the provisions governing forced draft boilers.
Model Number
A B C D E F G H I
Dimensions
ACB-110S-N 32-1/2” 17-1/4” 18” 14-3/4” 2-3/4” 6-1/2” 2-3/4” 2” 3-1/2” ACB-150S-N 32-1/2” 18-3/4” 18” 6-3/4” 2-3/4” 6-3/4” 11-3/4” 2-1/2” 6-1/4” ACB-199S-N 32-1/2” 18-3/4” 18” 5-1/2” 2-3/4” 6-3/4” 11-1/2” 2-1/4” 5-1/2”
Model Number
J K L M N O P Q R
Dimensions
ACB-110S-N 8-3/4” 13-1/2” 2-3/4” 9” 10-1/2” 5” 14-1/2” 12-3/4” 5” ACB-150S-N 2-3/4” 13-1/2” 3” 9” 11-1/2” 5” 6-1/4” 13-3/4” 6” ACB-199S-N 2-3/4” 13-1/2” 2-3/4” 9-1/2” 10-1/2” 2-3/4” 5-1/2” 13” 5-1/4”
B
J
R
Q
S
R
D
TOP
A
G
I
F
H
K
M N T U
M
O
P
P
N
O
D
C
Q
E
L
F
G
H
I
TOP
110 Models
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
© June 2018 A. O. Smith Corporation. All Rights Reserved
www.hotwater.com | 800-527-1953 Toll-Free USA
Page 2 of 2