Residential Gas Water Heaters
PROMAX® PLUS HIGH RECOVER FEATURES
HIGHEST RECOVERIES AND FIRST HOUR RATINGS
Capacity/input combinations up to 98 gallons/75,100 BTUs produce
recoveries up to 81 gallons per hour, with deliverable hot water up
to 150 gallons.
A. O. SMITH DYNACLEAN™ DIFFUSER DIP TUBE
Helps reduce lime and sediment buildup, maximizes hot water output. Made from longlasting PEX cross-link polymer.
GREEN CHOICE® GAS BURNER
Patented “Eco-Friendly” design reduces NOx emissions by up to 33%, complies with
Texas requirements for NOx emissions.
COREGARD™ ANODE ROD
A. O. Smith’s exclusive aluminum anode has a stainless steel core, protects tank
against corrosion longer versus ordinary mild steel anodes.
PUSH-BUTTON PIEZO IGNITER
Makes lighting pilot fast and easy with one-hand push-button spark ignition.
Standard on C3 Technology
HEAT TRAP NIPPLES*
Factory installed on most models.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
THICK CFC-FREE FOAM INSULATION
Improves efficiency.
A. O. SMITH PERMAGLAS®GLASS COATING
Protects steel tank from rust.
FACTORY-INSTALLED TEMPERATURE
AND PRESSURE (T&P) RELIEF VALVE
Top-mounted T&P Valve available as option on C3 Technology models.
CODE COMPLIANCE: UBC, CEC, SBCC, CABO, HUD,
BOCA NATIONAL CODES, ASHRAE/IES 90.1-1999 AND
2004 NAECA
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANS Z21.10.1* standards governing storage-type water heaters.
*75 and 100 models certified to ANS Z21.10.3
6-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products
Company.
EQUIPPED WITH C3 TECHNOLOGY
See other side.
®
models.
®
Series 100/101
Revised September 2008
®
Page 1 of 2
AOSRG45400
Residential Gas Water Heaters
MODEL
NUMBER
FIRST
HOUR
RATING
GALLON
CAPACITY
(GPH)
GCVT-40
GCVT-50
GCVX-50
GCV-65
FCG-75*
FCG-100*
Recovery capacity based on actual performance tests. Water Connections – 1" on 75-gallon model, 1-1/4" on 100-gallon model, 3⁄4" on all other models.
* Not equipped with C3 Technology. 75 and 100 gallon models have factory installed (non heat trap) nipples, 75-gallon model has 80% efficiency,
998 BTU/hr. standby loss; 100-gallon model has 80% efficiency, 1146 BTU/hr. standby loss.
† Propane Gas – GCVT-40: 47,000 BTU input; GCVT-50: 45,000 BTU input; GCVX-50: 55,000 BTU input; GCV-65: 62,500 BTU input.
For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XCVT-40), or change “F” to “P” in model number (example: PCG-75).
The standard FVIR models are certified for installations to 7700 feet elevation. For high attitude versions of the 75 & 100-gallon models add SMR “S19”
88 38 48
90 48 51
93 50 67
116 65 67
N/A 74 81
N/A 98 81
RECOVERY
90°F RISE
PER HOUR
ENERGY
FACTOR
BTU INPUT
PER HOUR
NATURAL
†
0.60 50,000 16
0.58
0.58
0.57
50,000 8
65,000 16
65,000
N/A 75,100 16
N/A
75,100 10
R
VALUE
A B C D E F
58-1/2 54-3/4 20-1/2 13-3/8 8 48-7/8
60-7/8 56-1/2 20 13-3/8 8 50-3/8
63-7/8 59-1/2 22 15-1/2 8 54-1/8
65 60 24 15-1/2 8 54-1/4
16
61 57 26-1/2 14-3/4 16 50-1/4
68-1/2 65 27-3/4 15-3/16 16 57-3/8
Flammable Vapor Ignition
Resistant C3 Technology
®
DIMENSIONS (INCHES)
DRAFT
HOOD
OUTLET
4
4
4
4
4
4
HOT CONNECTION
APPROX.
SHIPPING
WEIGHT
(LBS)
138
172
195
215
275
350
ANODE ROD*
Water Heaters
Corderite Combustion Containment (C3) design meets American National
Standards Institute standards (ANS Z21.10.1) that deal with the accidental or
unintended ignition of flammable vapors, such as those emitted by gasoline.
Covered by four U.S. patents, C3 Technology gas water heaters feature a sealed
E
C
COLD
CONNECTION
combustion chamber with air intake screen and a fireproof Corderite flame
arrestor built into the water heater base. In addition, a thermal cutoff (TCO)
device, integral with the thermocouple, is designed to shut off gas flow to the
burner and pilot if poor combustion is detected.
If flammable vapors
accidentally enter the
combustion chamber,
the Corderite flame
arrestor is designed
so flames burn off
the top surface and
cannot escape down
through the arrestor.
A. Easy-to-light
piezo igniter
For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised September 2008
B. View port for easy
burner inspection
inside sealed
combustion chamber
www.hotwater.com
T&P VALVE
1/2" GAS
CONNECTION
D
*Location for optional top-mounted
T&P Valve if ordered from factory.
(C3 models only)
A
B
F
Page 2 of 2
AOSRG45400