To prevent from fire or shock hazard,do not expose monitor to any rain or any form of water.High voltage is
inside the monitor so please do not remove the back cover of the cabinet if you are not a qualified
monitor engineer.Contact the local dealer or the nearest
AOpen
A. IMPORTANT SAFETY INSTRUCTION
Prior to using this service manual,please ensure that you have carefully followed all the procedures outlined in the
user's manual for this product.
1. Read all of these instructions.
2. Save these instructions.
3. Follow all warnings and instructions marked on the product.
4. Unplug this product from the wall outlet before cleaning.Do not use liquid cleaner or aerosol
cleaner, use a damp cloth for cleaning.
5. Do not use this product near water.
6. Do not place this product on an unstable cart,stand or table.The product may fall,causing serious
damage to the product.
7. Slots and openings in the cabinet and the back or bottom are provided for ventilation,to ensure
reliable operation of the product and to protect it from overheating.Those openings must not be
blocked or covered.The openings should never be blocked by placing the product on a bed,sofa, rug,
or other similar surface.This product should not be placed in a built-in installation,since proper
ventilation is provided.
8. This products should be operated with the type of power source indicated on the marked label.
If you are not sure of the type of power is available, consult with your dealer or local power company.
9. This product is equipped with a 3-wire grounding type plug,a plug having a third (grounding)
pin.This plug will only fit into a grounding-type power outlet.This is a safety feature.If you are
unable to insert the plug into the outlet,contact your electrician to replace your obsolete outlet.Do
not damage the purpose of the grounding-type plug.
10. Do not allow anything to rest on the power cord.Do not locate this product where persons will walk
on the cord.
11. Never push any kinds of objects into this product through cabinet slots as they may touch dangerous
voltage points or short out parts that could result in a risk of fire or electric shock.Never spill any kinds
of liquid on the product.
12. Do not attempt to service this product yourself,as opening or removing covers may expose you to
dangerous voltage points or other risk.Refer all servicing to service personnel.
13. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
following conditions.
a. When the power cord or plug is damaged or frayed.
b. If liquid has been spilled into the product.
c. If the product has been exposed to rain or water.
d. If the product does not operate normally,when the operating instructions are followed.Adjust
only those controls involved in the operating instructions ,since improper adjustment of
other controls may result in damage and will often require extra work by a qualified
technician to restore the product to normal operation.
e. If the product has been dropped or the cabinet has been damaged.
f.
If the product exhibits a distinct change in performance,indicating a need for service.
1. Make the adjustment to the value shown at right by turning the VR501 on the main PCB.
Adjusting
Value
15.5V
±0.2V
High Voltage
Adjust
B
Preset
Adjust
C
﹟Digital Voltmeter
﹟High Voltage
Probe
﹡Anode Cap-GND
﹫Crosshatch Pattern
(31.5KHz,640x480)
﹫Crosshatch
(31.5KHz,640x480)
1. Turn the power switch of the monitor OFF.
2. Connect high voltage probe to Anode Cap and
GND.
3. Turn the power switch of the monitor ON.
(15 minutes)
4. Make the adjustment to the value shown at right
by turning the VR601 on the main PCB.
1. Uplug the power cord of the monitor.
2. Hold key,then plug the power cord of
the monitor.
3. Hold key,make sure into preset
picture,if not ,please return 1-2.
4. Please following the procedure of selection and
adjusting an item using the OSD system as below
steps for main function adjusent.
Step 1 : Press and relese the OSD control knob to
activate the OSD menu.
Step 2 : Press or key to highlight the desired
option of OSD icon.
Step 3 : Press and release key to acress the
option.The color of the inner area of the
OSD will changed from blue to green.
Step 4 : To make your adjustment,press or
key to decrease the setting.
Step 5 : Press and release key to store
the change.the color of the inner area will
go back to blue.You can select select other
function to make adjustment by or key.
Also you can select exit icon or press
key to exit the OSD menu.
25.5KV
±0.1KV
Contrast :
MAX.
Brightness
MAX.
H-Size :
mm
306
V-Size :
230
mm
H-Posi. :
Center
V-Posi :
Center
Other adj. :
Best Point
A70PF(RX-777NS) 7 / 33
ITEM
rogram Menu.
﹟Test Meter
﹡Test Point
﹫Pattern
Operation
Adjusting
Value
Background
White
Balance
D
Adjust
White
Balance
Adjust
E
ABL
Adjust
F
﹟Color Analyzer
﹫R.G.B off
(68KHz,1024x768)
﹟Color Analyzer
﹟Oscilloscope
﹡Cathode G
﹫3” block
(68KHz,1024x768)
﹟Color Analyzer
﹫Full White
(68KHz,1024x768)
1. Set the contrast to MAX.,Brightness to Y=0.7
K
set color is 9300
using the OSD.
°
2. Set the OSD to COLOR of sub menu and press
knob.
3. Make the adjustment R.G.B BIAS low light to
the value shown at right by using and key.
1. Move the OSD to the R.G.B. DRIVE.
2. Move the OSD to the G DRIVE and make the
adjustment to the value shown at right by using
and key.
3. Move the OSD to the R,B-DRIVE and make the
Adjustment to the value shown at right by using
and key.
1. Set the contrast to MAX.,Brightness to MAX.
2. Make the adjustment to the value shown at right
by adjustment ABL on the OSD menu.
Y = 0.4
±0.1FL
x = 0.283
±0.015
y = 0.297
±0.015
P-P
37V
Y=58FL
x = 0.283
±0.015
y = 0.297
±0.015
Y =
33FL ±3
G
Other
Function
Seting
﹫Full White
(85Hz 1024*768)
1. Set the FREQ. to 73
2. Set the OSD to PROVIEW
3. Set the BURN to Disable
4. Set the DEFO to TDA9116/9118
A70PF(RX-777NS) 8 / 33
ITEM
rogram Menu.
Dynamic
Focus
H
Adjust
Purity
Adjust
I
﹟Test Meter
﹡Test Point
﹫Pattern
﹟Oscilloscope
﹡FBT Pin14
﹫Full White
(31.5KHz,640x480)
﹫Magenta color
(31.5KHz,640x480)
Operation
1. Set the contrast to MAX.,and adjustment
Brightness to the raster just appear.
2. Make the adjustment to the value shown at right
by adjust the VF on the OSD menu.
3. Make the check to the value shown at right by
adjust the HF on the OSD menu.
1. Adjust the purity magnet is in magneta color.
2. Turning two overlapping pawels in opposite
directions.
3. Move them until they are at the same angle,
9 o’clock and 3 o’clock respectively.
Adjusting
Value
VF :
150(17”)
±10V
P-P
HF :
350(17”)
±10V
P-P
Static
Convergence
Adjust
J
﹫
Magenta color
(31.5KHz,640x480)
1. Open the two pawels of the 4 pole magnets to
allow the red and blue vertical lines to unite.
2. Open and rotate the two pawels at a contrast
angle so that the red and blue horizontal lines
can unite.
3. If the vertical lines deviates,open the two powals
at the deviation position and make a monitor
adjustment by changing its angle.
4. Display white crosshatch pattern.
5. Make the red and blue vertical lines at the
center unite with the green by opening the two
6 pole pawels.
6. Rotate the two pawels at contrast angle so that
the red and blue horizontal lines can unite with
the green.
7. If the vertical lines deviate,change the angle of
Pawels from the deviation position.
A70PF(RX-777NS) 9 / 33
A70PF(RX-777NS) 10 / 33