anvil international 1011, 1018 User Manual

CAST IRON FLANGES
X
O
Y
V
V
Class 125 (Standard)
Min.
FIGURE 1011
q
Companion Flange
Pipe Size
NPS DN in mm in mm in mm in mm lbs kg lbs kg
3
/4* 20 37/8 987/16 11 13/4 445/8 16 1.50 0.68 1.50 0.68
1 25 4
1
1
/4 32 45/8 1171/2 13 25/16 5913/16 22 2.00 0.91 2.00 0.91
1
1
/2 40 5 1279/16 14 29/16 657/8 22 2.25 1.02 2.25 1.02
Diameter of Flange
1
/4 1087/16 11 115/16 4911/16 17 1.75 0.79 1.75 0.79
2 50 6 152
1
2
/2 65 7 17811/16 17 39/16 90 11/8 29 6.00 2.72 6.00 2.72
3 80 7
1
3
/2 90 81/2 21613/16 21 413/16 122 11/4 32 9.00 4.08
1
/2 1913/4 19 41/4 108 13/16 30 7.63 3.46 7.63 3.46
4 100 9 229
Q
5 125 10 254 6 150 11 279 1 25 7
1
/2 343 11/8 29 911/16 246 13/4 44 26.00 11.79 26.00 11.79
When ordering companion flanges,
always give outside diameter as well as nominal pipe size.
* Anvil size; not covered by ASME B16.1.
FIGURE 1018
q
Blind Flange
10 x 16 (NPS) and smaller
8 200 13 10 250 16 406 1 12 300 19 483 1
Pipe Size
I
NPS DN in mm in mm in mm lbs kg lbs kg
1 25 41/4 108
1
1
/4 32 45/8 117
1
1
/2 40 5 127
2 50 6 152
1
2
/2 65 7 178
Q
I
O
12 x 19 (NPS) and larger
3 80 7
1
3
/2 90 81/2 216
4 100 9 229
5 125 10 254
Q
I
O
I
6 150 11 279 1 25
8 200 13
10 250 16 406 1
12 300 19 483 1
All Class 125 cast iron standard flanges have a flat face. Blind Flange 12 x 19 NPS supplied dished with inside radius to the pipe diameter. When ordering blind flanges, always give the outside diameters.
Note: See following page for pressure-temperature ratings.
Min. Flange
Thickness
O
Q
5
/8 16 31/16 78 1 25 4.00 1.81 4.00 1.81
15
/16 24 55/16 135 15/16 33 11.75 5.33 11.75 5.33
15
/16 24 67/16 164 17/16 37 14.00 6.35 14.00 6.35
3
/16 30 1115/16 303 115/16 49 37.75 17.12 37.75 17.12
1
/4 32 141/16 357 23/16 56 50.50 22.91 50.50 22.91
Diameter of Flange
O
1
/2 191
1
/2 343 11/8 29 11/16 27 40.00 18.14 40.00 18.14
Diameter
of Hub
9
/16 192 19/16 40 16.50 7.48 16.50 7.48
Min. Flange
Thickness
Q
7
/16 11
1
/2 13
9
/16 14
5
/8 16
11
/16 17
3
/4 19
13
/16 21
15
/16 24
15
/16 24
3
/16 30 11/8 29 59.00 26.76
1
/4 32
X
Min. Length
Through
Hub
Y
Wall
Black Paint Galvanized
Unit Weight
Unit Weight
Thickness
V
3
/8 10 2.00 0.91 2.00 0.91
7
/16 11 2.25 1.02 2.25 1.02
1
/2 13 3.75 1.70
9
/16 14 4.00 1.81 4.00 1.81
5
/8 16 6.75 3.06
11
/16 17 8.00 3.63 8.00 3.63
3
/4 19 11.00 4.99
7
/8 22 14.00 6.35 14.00 6.35
7
/8 22 18.00 8.16 18.00 8.16
15
/16 24 23.00 10.43 23.00 10.43
13
/16 21 88.00 39.92
Black Paint Galvanized
PROJECT INFORMATION APPROVAL STAMP
Project:
Address:
Contractor:
Engineer: Remarks:
Submittal Date:
Notes 1:
Notes 2:
PF-11.16
Approved
q
Approved as noted
q
q
CAST IRON FLANGED FITTINGS AND FLANGES
Class 125 (Standard) and Class 250 (Extra Heavy)
For Listings/Approval Details and Limitations, visit our website at
www.anvilintl.com or contact an Anvil Sales Representative.
Specifications
All Cast Iron Flanged Fittings and Flanges in sizes listed are made to ASME and are marked 125 or 250 for pipe sizes 12 NPS Unless otherwise specified, cast iron flanges and fittings are drilled and
faced in accordance with ASME B 16.1.
Coatings
Flanged fittings and flanges are available in both black painted and galvanized. Consult an Anvil Representative for available sizes.
Sizes
Size of all flanged fittings and flanges scheduled indicates nominal pipe diameter of ports. Standard reducing elbows carry the same dimensions center-to-face as regular elbows of largest straight size.
(300 DN)
and smaller.
Ordering
To order reducing companion flanges, specify threaded or reduced size first, then the outside diameter of flange wanted. For instance, if a reducing flange is required to connect a 5-inch pipe to an 8-inch flanged valve or fitting having a 13 1/2 inch O.D. flange, order: 5 x 13 1/2 inch standard reducing flange.
Dimensions
Bolt holes for bolts smaller than 1 3/4 inches are drilled 1/8 inch larger than the bolt diameter; 1 3/4 inch and larger bolts have holes drilled 1/4 inch diameter. Bolt holes straddle the center line. Bolt holes are spot faced on order only.
(44mm)
(6mm)
larger than bolt
in diameter
(44mm)
Tolerances
An inspection limit of plus or minus 1/32 inch all center to contact surface dimensions for sizes up to and including 10 NPS
(250 DN)
NPS
(250 DN)
be allowed on all contact surface to contact surface dimensions for sizes up to and including 10 NPS on sizes larger than 10 NPS governs the tolerance to be applied to all openings.
; plus or minus 1/16 inch
. Inspection limit of plus or minus 1/16 inch
(250 DN)
(250 DN)
. The largest opening in the fitting
(1mm)
shall be allowed on
(1.5mm)
on sizes larger than 10
(1.5mm)
; plus or minus 1/8 inch
shall
(3mm)
Standards and Specifications
Dimensions Material Galvanizing
Cast Iron Flanged Fittings and Cast Iron Flanges
Pressure*
Temperature
Class 125 Class 250
1"–12" 1"–12"
(°F) (°C) psi bar psi bar
-20° to 150° -28.9˚ to 65.6˚ 200 13.8 500 34.5 200° 93.3˚ 190 13.1 460 31.7 225° 107.2˚ 180 12.4 440 30.3 250° 121.1˚ 175 12.1 415 28.6 275° 135.0˚ 170 11.7 395 27.2 300° 148.9˚ 165 11.4 375 25.9 325° 162.8˚ 155 10.7 355 24.5 350° 178.3˚ 150 10.3 335 23.1 375° 190.6˚ 145 10.0 315 21.7 400° 207.8˚ 140 9.7 290 20.0 425° 218.3˚ 130 9.0 270 18.6 450° 232.2˚ 125 8.6 250 17.2
* Applies to fittings and flanges manufactured with ASTM A-126 Class B
material only.
**
Thread Pressure Rating
CAST IRON FLANGES AND FLANGED FITTINGS
Class 125 (1"-12") ASME B16.1 ASTM A- 126 (A) or (B) ASTM A-153 ASME B1.20.1 ASME B16.1 Class 250 (1"-12") ASME B16.1 ASTM A- 126 (A) or (B) ASTM A-153 ASME B1.20.1 ASME B16.1
** ASTM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard.
PF-11.16