The VZN system is an innovative filtration system that uses
proprietary multi-bore hollow fiber membranes as well as a
carbon element to provide the latest innovation in filtration
technology.
This manual provides the safety, installation, and
operating procedures for the VZN water filtration system. All
information contained in this manual should be read prior to
installing and operating the system. Your VZN system is manufactured from the finest materials available and is assembled
to strict quality standards. This system has been tested at the
factory to ensure dependable trouble-free operation.
Warranty Information
Please read the full text of the Limited Warranty in this
manual.
If the system arrives damaged, contact the carrier immediately and file a damage claim with them. Save all packing materials when filing a claim. Freight damage claims are the responsibility of the purchaser and are not covered under warranty.
The warranty does NOT extend to:
• Damages caused in shipment or damage as result of
improper use.
• Installation of electrical service.
• Normal maintenance as outlined in this manual.
• Malfunction resulting from improper maintenance.
• Damage from moisture leaking into electrical
components.
• Damage from tampering with, removal of, or changing
any preset control or safety device.
IMPORTANT! Keep these instructions for future reference. If the system changes
ownership, be sure this manual accompanies the equipment.
2
P/N 1011079 Rev. J 01/14
OWNER INFORMATION (continued)
Service/Technical Assistance
If you experience any problems with the installation or operation of your system, contact A.J. Antunes & Co. at 1-630-784-1000, or toll free in the United States at 1-800-253-2991.
Fill in the information in the next column and have it handy
when calling for assistance. The serial number is on the
specification plate located on the system.
Purchased From:
Date of Purchase:
Model No.:
Serial No.:
Mfg. No.:
VZN V SERIES
Suggested replacement period for the Ultra Filter Cartridge is
approximately 3 years.
For sales in the state of Iowa:
Seller: Date:
Buyer: Date:
IMPORTANT
A.J. Antunes and Company reserves the right to change specifications and product
design without notice. Such revisions do NOT entitle the buyer to corresponding
changes, improvements, additions, or replacements for previously purchased equipment.
P/N 1011079 Rev. J 01/14
3
VZN V SERIES
IMPORTANT SAFETY INFORMATION
In addition to the warnings and cautions in this manual, use
the following guidelines to safely operate the system:
• Read all instructions before using equipment.
• Install or locate the equipment only for its intended use
as described in this manual.
• Do NOT use corrosive chemicals in this equipment.
• Do NOT operate this equipment if it has a damaged
cord or plug; if it is not working properly, or if it has
been damaged or dropped.
• This equipment should be serviced by qualified personnel only. Contact A.J. Antunes & Co. for repair.
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
• This equipment should be supplied with only cold
water.
• For installations in Massachusetts, the Commonwealth
of Massachusetts Plumbing Code 248 CMR shall be
adhered to. The use of saddle valves are not permitted.
Please consult your local plumber.
The following warnings and cautions appear throughout this
manual and should be carefully observed.
• Unplug the power cord before performing any
service or maintenance on the unit.
• All electrical connections must be in accordance with
local electrical codes and any other applicable codes.
• WARNING ELECTRICAL SHOCK HAZARD. FAILURE
TO FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS INJURY OR DEATH.
- Do NOT modify the power supply cord plug. If it
does not fit the outlet, have a proper outlet installed
by a qualified electrician.
- Do NOT use an extension cord with this unit.
• If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent, or a similarly qualified person.
• This equipment is to be installed to comply with the
local plumbing code and any other applicable code.
• Water pressure must not exceed 100 psig (690 kPa).
To reduce water pressure, install a water pressure
regulator and set to suit the application.
• The trans membrane pressure (inlet pressure minus
the permeate water pressure) must not exceed 45 psi
(310 kPa).
• A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
• When installed on metallic plumbing, a properly sized
electrical bonding jumper must be installed across the
inlet and outlet pipes serving this unit.
NOTE: If the inlet water pressure is less than 50 psig (345
kPa), it is recommended that a suitably-sized booster
system (outlet pressure 60 psig - 100 psig max (414 kPa 690 kPa max) be installed.
4
P/N 1011079 Rev. J 01/14
VZN V SERIES
IMPORTANT SAFETY INFORMATION (continued)
Protect from becoming dry
If the membrane dries out, irreversible damage to the Ultra
Filter membrane may result. Protect the filter from becoming
dry by keeping it wet and sealed at all times.
Protect from freezing
If the Ultra Filter membrane freezes during operation or storage, irreversible damage to the membrane and brittle cracking of the cartridge or housing may result.
Protect from direct sunlight or other UV sources
Avoid long-term exposure to direct sunlight or other UV
sources. The Ultra Filter should be stored in a dark location.
Protect from high temperatures or abrupt variation in
temperature
The maximum operating temperature is 100°F (38°C). Avoid
abrupt variations in temperature. Any temperature variation
should be made slowly.
Protect from rough handling or dropping
Mechanical damage, external breakage, and/or internal
breakage of the filter can result if the system is dropped or
bumped. Handle with care at all times during transportation
and installation.
Protect from organic solvents and concentrated acids
Prevent any and all contact of the membrane with strong solvents, solvents containing chlorine, or concentrated acids. Do
NOT use strong solvents or concentrated acids on any plastic
parts of the filter system. Examples of some solvents to avoid:
acetone, methyl acetate (nail polish remover); hexane (spot
removers); turpentine, toluene (paint thinners); dry cleaning
solutions, insecticides.
CAUTION
This equipment is to be installed to comply with the
basic plumbing code of the Building Officials and Code
Administrators, Inc. (BOCA) and the Food Service
Sanitation Manual of the Food and Drug Administration
(FDA).
CAUTION
Water Flow Regulator Assemblies are NOT interchangeable. Operating the system with the wrong Water Flow
Regulator or without a regulator can damage the system, cause personal injury, and voids the warranty!
CAUTION
All electrical connections must be in accordance with
local electrical codes and any other applicable codes.
A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
When installed on metallic plumbing, a properly sized
electrical bonding jumper must be installed across the
inlet and outlet pipes serving this unit.
Protect from abrasive material
The membranes must be protected from abrasive materials
like shavings left in a pipe. Abrasive materials in contact with
the membrane can cause irreversible damage to the membrane. All pipes must be flushed clean before installing the filter. All plastic parts of the filter system must be protected from
sharp objects like knives, sand paper, or other tools. Cutting
or nicking a plastic part can weaken it and cause a leak. Do
NOT use abrasive cleansers on any plastic parts.
Protect from water hammer
The system must be protected from shock, pressure surges,
or pulsation that may occur inside water pipes. Water hammer occurs in pipes when a valve or faucet shuts quickly.
Install a water hammer arrestor (pressure vessel containing
compressed air separated from the water by a diaphragm) to
reduce pressure shock.
P/N 1011079 Rev. J 01/14
5
VZN V SERIES
MAY VA RY
SPECIFICATIONS
Dimensions
VZN-441V-T5VZN-441V
C
Model &
Mfg. No.
VZN-441V
9700741
VZN-441V-T5
9700751
A
B
C
Width
(A)
24"
(61 cm)
32 3/4"
(83 cm)
Depth
(B)
10 1/8"
(26 cm)
10 1/8"
(26 cm)
A
B
Height
(C)
49 5/16"
(125 cm)
49 5/16"
(125 cm)
CAUTION
All electrical connections must be in accordance with
local electrical codes and any other applicable codes.
Electrical Ratings
Model &
Mfg. No.
VZN-441V
9700741
VZN-441V-T5
9700751
NOTE: Includes plug adaptors for US, Europe, Australia, and UK.
VoltsWattsAmpsHertz
100–24010.0850/60
100–24010.0850/60
Replacement Cartridges
ReplacementPart Number
VZN-441V
VZN-441V-T5
VZN-441V
VZN-441V-T5
VZN-441V-T5TAC-05 Cartridge7000554
L-440 Ultra Filter7000412
Carbon Element7000669
Electrical Cord & Plug Configurations
Kit Model
Number
DescriptionConfiguration
DC Power Supply
100 - 240 VAC
0012146
Includes the
4 plug adaptors
below
NOTE: PLUG STYLE
A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
When installed on metallic plumbing, a properly sized
electrical bonding jumper must be installed across the
inlet and outlet pipes serving this unit.
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pin)
Euro
CEE 7/16
AS/NZS
3112
AUS
(2 Pin)
UK
BS 136 3
6
P/N 1011079 Rev. J 01/14
PERFORMANCE DATA SHEET
VZN V SERIES
Filter Cartridge Capacities
Maximum Operating Pressure100 psig (690 kPa)
Maximum Operating Temperature100°F (38°C)
Minimum Operating Temperature40°F (4°C)
Maximum Trans Membrane Pressure45 PSI (3.1 Bar)
pH Range3-10
MWCO100 kD
NSF/WQA Certified Rated Service
Flow:
VZN-441V & VZN-441V-T513 gpm (49 l/m)
System Tested and Certified by NSF
International and WQA against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction
as verified and substantiated by test data.
Performance Claims for Percent Reduction
SubstanceInfluent
1
cyst
Turbidity11 ± 1 NTU≤ 0.5 NTU99.1%
Particulate Class I
Particles 0.5 to <
1µm
1
based on the use of microspheres or Cryptosporium parvum oocysts
Challenge
Concentration
minimum
50,000/L
at least 10,000
particles /mL
Reduction
Requirement
99.95%99.95%
≥ 85%N/A
Minimum
Reduction
%
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance
This system has been tested according to NSF/ANSI
Standard 42 and 53 for reduction of the substances listed
below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 or 53. While testing was performed under standard laboratory conditions, actual performance may vary.
NOTE: The NSF/WQA information provided applies to the
Ultra Filter cartridge.
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain filterable cysts.
P/N 1011079 Rev. J 01/14
7
VZN V SERIES
Overview
OPERATION
The VZN system operates in two modes:
• Normal Operation Mode
• Flush Mode
During Normal Operation Mode, water enters the Inlet and
flows through the Ultra Filter before exiting the Permeate
Outlet as usable product water.
During Flush Mode, the Drain Valve opens and water entering the Inlet flushes and cleans the Ultra Filter membrane by
removing any debris collecting on the membrane wall.
The Drain Valve is only powered during Flush Mode.
NOTE: Do NOT unplug the power cord or turn off the system during Flush Mode. If there is a power outage or the
system is unplugged, water will continue to be filtered
but the system will NOT flush. This could cause the Ultra
Filter to plug prematurely and may reduce the life of the
filter.
The flush is automated by the Universal Pulse Controller to
last 10 seconds and take place in one-hour intervals. This
interval can be changed (see Changing the Interval Setting
in the Maintenance section of this manual).
CAUTION
Changing the flush interval may cause the Ultra Filter
to plug prematurely and may reduce the life of the filter.
Consult the factory for more information.
Ultra Filtration
Cartridge
System
Flush
Solenoid
Valve
(Automatic)
Carbon Element
Housing
Inlet
Ball Valve
(Manual)
(VZN-441V-T5 only)
Figure 1. System Components
Rinse
Ball Valve
(Manual)
Check Valve
Assembly
with Outlet
Pressure Gauge
Outlet
Ball Valve
(Manual)
TAC Cartridge
Housing
Manual Flushing
A manual flush can be activated at any time by pressing the
FLUSH button on the Universal Pulse Controller.
When the FLUSH button is pressed, the Flush LED on the
controller flashes and the Drain Valve opens for 10 seconds.
After flushing is complete, the Drain Valve will close, the Flush
LED will stop flashing and the unit will automatically return to
Normal Operation Mode.
NOTE: A manual flush will not affect the interval flush
setting.
8
P/N 1011079 Rev. J 01/14
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.