Antunes VZN-441VA Operators Manual

Water Filtration System
Model VZN-441VA
owner’s manual
Manufacturing Numbers:
9700776
Cartridge Tested and Certied by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Eects Nominal Particulate Reduction Class I
Standard No. 53: Health Eects Cyst Reduction & Turbidity Reduction as veried and substantiated by test data.
www.antunes.com
P/N 1011202 Rev. C 11/16
CONTENTS
General ...................................................... 2
Warranty
Information ............................................... 2
Service/Technical
Assistance ..................................................2
Important Safety
Information ............................................... 3
Specications ............................................ 4
Performance Data Sheet ..........................5
Installation ................................................ 6
Operation ................................................12
Maintenance ...........................................13
Troubleshooting .....................................16
Replacement Parts..................................17
Notes ........................................................19
IMPORTANT
A.J. Antunes & Co. reserves the right
to change specications and product
design without notice. Such revisions do
not entitle the buyer to corresponding
changes, improvements, additions or
replacements for previously purchased
equipment.
IMPORTANT
Keep these instructions for future reference.
If the unit changes ownership, be sure this
manual accompanies the equipment.
GENERAL
This manual provides the safety, installation, and operating procedures for the VZN water ltration system. All information contained in this manual should be read prior to installing and operating the system.
This system is manufactured from the nest materials available and is assembled to strict quality standards. This system has been tested at the factory to ensure dependable trouble-free operation.
WARRANTY INFORMATION
Please read the full text of the Limited War­ranty in this manual.
If the system arrives damaged, contact the carrier immediately and le a damage claim with them. Save all packing materials when ling a claim. Freight damage claims are the responsibility of the purchaser and are not covered under warranty.
The warranty does NOT extend to:
y Damages caused in shipment or
damage as result of improper use.
y Installation of electrical service. y Normal maintenance as out-
lined in this manual.
y Malfunction resulting from
improper maintenance.
y Damage from moisture leaking into
electrical components.
y Damage from tampering with,
removal of, or changing any pre­set control or safety device.
SERVICE/TECHNICAL ASSISTANCE
If you experience any problems with the installation or operation of your system, contact A.J. Antunes & Co. at 1-630-784­1000, or toll free in the United States at 1-800-253-2991.
Fill in the information in the next column and have it handy when calling for assis­tance. The serial number is on the specica­tion plate located on the system.
Purchased From
Date of Purchase
Model Number
Serial Number
Mfg. Number
Suggested replacement period for the Ultra Filter Cartridge is approximately 3 years.
For sales in the state of Iowa:
Seller:
CAUTION
All electrical connections must be in
accordance with local electrical codes and
any other applicable codes.
A ground fault circuit interupter (GFCI) must
be installed on the circuit to this system.
When installed on metallic plumb-
ing, a properly sized electrical bonding
jumper must be installed across the inlet
and outlet pipes serving this unit.
IMPORTANT
This equipment is to be installed to comply with the basic plumbing code of the Building Ocials and Code Ad-
ministrators, Inc. (BOCA) and the Food Service Sanitation Manual of the Food
and Drug Administration (FDA).
Date:
Buyer:
Date:
IMPORTANT
Water Flow Regulator Assemblies are NOT
interchangeable. Operating the system with
the wrong Water Flow Regulator or without
a regulator can damage the system, cause
personal injury, and voids the warranty!
P/N 1011202 REV. C 11/162
IMPORTANT SAFETY INFORMATION
In addition to the warnings and cautions in this manual, use the following guidelines to safely operate the system:
y Read all instructions be-
fore using equipment.
y Install or locate the equip-
ment only for its intended use as described in this manual.
y Do NOT use corrosive chemi-
cals in this equipment.
y Do NOT operate this equipment
if it has a damaged cord or plug; if it is not working properly, or if it has been damaged or dropped.
y This equipment should be serviced
by qualied personnel only. Con­tact A.J. Antunes & Co. for repair.
y Do NOT immerse cord
or plug in water.
y Keep cord away from heated surfaces. y This equipment should be sup-
plied with only cold water.
y For installations in Massachusetts,
the Commonwealth of Massachu­setts Plumbing Code 248 CMR shall be adhered to. The use of saddle valves are not permitted. Please consult your local plumber.
The following warnings and cautions appear throughout this manual and should be care­fully observed.
y Unplug the power cord before per-
forming any service or maintenance on the unit.
y All electrical connections must be in
accordance with local electrical codes and any other applicable codes.
y Warning electrical shock hazard.
Failure to follow these instructions could result in serious injury or death.
y Do NOT modify the power sup-
ply cord plug. If it does not t the outlet, have a proper outlet in­stalled by a qualied electrician.
y Do NOT use an exten-
sion cord with this unit.
y If the supply cord is damaged, it
must be replaced by the manu­facturer, its service agent, or a similarly qualied person.
y This equipment is to be installed
to comply with the local plumbing code and any other applicable code.
y Water pressure must not exceed 100
psig (690 kPa). To reduce water pres­sure, install a water pressure regula­tor and set to suit the application.
y The trans membrane pressure
(inlet pressure minus the per­meate water pressure) must not exceed 45 psi (310 kPa).
y A ground fault circuit inter-
rupter (GFCI) must be installed on the circuit to this system.
y When installed on metallic
plumbing, a properly sized elec­trical bonding jumper must be installed across the inlet and outlet pipes serving this unit.
NOTE: If the inlet water pressure is less
than 50 psig (345 kPa), install a suitably sized booster system (outlet pressure 60 psig - 100 psig max (414 kPa - 690 kPa max).
Protect from becoming dry
If the membrane dries out, irreversible dam­age to the Ultra Filter membrane may result. Protect the lter from becoming dry by keeping it wet and sealed at all times.
Protect from freezing
If the Ultra Filter membrane freezes during operation or storage, irreversible damage to the membrane and brittle cracking of the cartridge or housing may result.
Protect from direct sunlight or other UV sources
Avoid long-term exposure to direct sunlight or other UV sources. The Ultra Filter should be stored in a dark location.
Protect from high temperatures or abrupt variation in temperature
The maximum operating temperature is 104°F (40°C). Avoid abrupt variations in tem­perature. Any temperature variation should be made slowly.
Protect from rough handling or dropping
Mechanical damage, external breakage, and/or internal breakage of the lter can result if the system is dropped or bumped. Handle with care at all times during trans­portation and installation.
Protect from organic solvents and con­centrated acids
Prevent any and all contact of the mem­brane with strong solvents, solvents containing chlorine, or concentrated acids. Do NOT use strong solvents or concen­trated acids on any plastic parts of the lter system. Examples of some solvents to avoid: acetone, methyl acetate (nail polish remover); hexane (spot removers); turpen­tine, toluene (paint thinners); dry cleaning solutions, insecticides.
Protect from abrasive material
The membranes must be protected from abrasive materials like shavings left in a pipe. Abrasive materials in contact with the membrane can cause irreversible damage to the membrane. All pipes must be ushed clean before installing the lter. All plastic parts of the lter system must be protected from sharp objects like knives, sand paper, or other tools. Cutting or nicking a plastic part can weaken it and cause a leak. Do NOT use abrasive cleansers on any plastic parts.
Protect from water hammer
The system must be protected from shock, pressure surges, or pulsation that may occur inside water pipes. Water hammer occurs in pipes when a valve or faucet shuts quickly. Install a water hammer arrestor (pressure vessel containing compressed air separated from the water by a diaphragm) to reduce pressure shock.
P/N 1011202 REV. C 11/16 3
SPECIFICATIONS
MAY VA RY
C
A
B
Model & Mfg. No.
VZN-441VA
9700776
Kit Model
Number
0012146
Width
(A)
24"
(61 cm)
Description Conguration
DC Power Supply
100 - 240 VAC
Includes the
4 plug adaptors below
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pin)
Euro
CEE 7/16
NOTE: PLUG STYLE
Depth
(B)
10 1/8"
(26 cm)
Height
(C)
49 5/16" (125 cm)
Electrical RatingsElectrical Cord & Plug Congurations
Model & Mfg. No.
VZN-441VA
9700776
Volts Watts Amps Hertz
100–240 10 .08 50/60
Replacement Cartridges
Replacement Part Number
VZN-441VA L-440 Ultra Filter 7000412
VZN-441VA Carbon Element 7000893
AS/NZS
3112
AUS
(2 Pin)
UK
BS 1363
P/N 1011202 REV. C 11/164
PERFORMANCE DATA SHEET
Filter Cartridge Capacities
Maximum Operating
Pressure
Maximum Operating
Temperature
Minimum Operating
Temperature
Maximum Trans
Membrane Pressure
pH Range 3-10
MWCO 100 kD
Rated Service Flow:
VZN-441VA
Cartridge Tested and Certied by NSF International against NSF/ANSI Standard 42 and 53 for the reduc­tion of:
Standard No. 42: Aesthetic Eects Nominal Particulate Reduction Class I
Standard No. 53: Health Eects Cyst Reduction & Turbidity Reduc­tion as veried and substantiated by test data.
100 psig (690 kPa)
104°F (40°C)
40°F (4°C)
45 PSI (3.1 Bar)
13 gpm (49 l/m)
Performance Claims for Percent Reduction
Substance
cyst1 minimum 50,000/L 99.95% 99.95%
Turbidity 11 ± 1 NTU ≤ 0.5 NTU 99.1%
Particulate Class I
Particles 0.5 to < 1µm
1based on the use of microspheres or Cryptosporium parvum oocysts
Inuent Challenge
Concentration
at least 10,000
particles /mL
Reduction Requirement
Minimum % Reduc-
tion
≥ 85% 99.5%
Cartridge has been tested according to NSF/ ANSI Standard 42 and 53 for reduction of the substances listed below. The concentra­tion of the indicated substances in water entering the system was reduced to a con­centration less than or equal to the permis­sible limit for water leaving the system, as specied in NSF/ANSI 42 or 53. While testing was performed under standard laboratory conditions, actual performance may vary.
NOTE: The NSF information provided ap-
plies to the Ultra Filter cartridge.
NOTE: Do not use with water that is mi-
crobiologically unsafe or of un­known quality without adequate disinfection before or after the system. Systems certied for cyst reduction may be used on disin­fected waters that may contain lterable cysts.
P/N 1011202 REV. C 11/16 5
INSTALLATION
Unpacking
1. Open the large box. It should
contain:
a. Plate-mounted VZN system with
Ultra Filter Cartridge installed
b. Padded envelope containing:
• Power Adaptor
• Adaptor Plugs
• Owner’s Manual
• Mounting Bracket
• Filter Wrench
• Glove and Sticker Kit
• Sanitizing T-Fitting and Plug
c. Carbon Element and Carbon Ele-
ment Housing
2. Remove all packing materials and protective coverings from the system.
3. Remove the information packet. Fill out and mail the warranty card immediately to pre­vent any delay in obtaining warranty coverage.
NOTE: If any parts are damaged, contact
A.J. Antunes & Co. IMMEDIATELY at 1-800-253-2991 (toll free in the U.S. and Canada) or 1-630-784-
1000.
Equipment Setup
General
When placing the system into service, pay attention to the following guidelines:
y Do NOT immerse cord
or plug in water.
y Keep cord away from heated surfaces.
Electrical
The line voltage must match the voltage on the specication label. The plug on the power cord must match the appropriate outlet. Do NOT connect the system to a switched electrical outlet.
Plumbing
NOTE: The system must be connected to
the COLD water line. Do NOT con­nect the system to the hot water line.
This system uses the following connections:
Connection Description
System Inlet 3/4” NPT
System Outlet
(Product Water)
Drain 3/4” FNPT
Rinse Outlet
When making a plumbing connection to the system, use a back-up wrench on the supporting plumbing. Always use a quality, approved pipe sealant or thread seal tape on pipe threads. Do NOT allow pipe sealant inside pipes.
Do NOT over tighten the connections. Use plastic ttings when connecting to the plastic connections of the system.
If soldered plumbing is used, do NOT apply heat to, or near, the ltration system. Use union (O-ring seal) connections for ease of installation and future servicing.
3/4” NPT
3/4” (Garden Hose or 3/4”
ID Hose)
Suggested Tools and Supplies for Instal­lation
The following tools and supplies are sug­gested to help with the installation:
y Screwdriver y Adjustable Wrenches y Drill with Bits y Level y Tape Measure y Pipe Dope or Thread Seal Tape y Two Gallon Bucket y Fresh, Unscented Liq-
uid Chlorine Bleach
y Pipe Wrenches y Garden Hose (for rinsing) y Hose or pipe for drain line
P/N 1011202 REV. C 11/166