Ansen Electronics Co W174TX 0 Users Manual

Personal Weather Station
with Wireless Sensors for
Temperature & Humidity/Wind
Speed/Rain
Model # 47009
Thank you for purchasing this Celestron personal weather station. Please read the instructions prior to using it and we hope you will have many years of pleasure with it.
You will need the following tools and supplies to mount the Anemometer and Rain Gauges --- small Phillips screwdriver, hex key – 5mm (3/16”), drill, level, pencil and mast.
ENGLISH
Set Up Power for the Receiver
Open the battery compartment door on the rear of the Receiver (located in top center of image on the left). Then insert six AA batteries (user supplied) with polarity as indicated in the battery compartment (see image on the right). After installation, put the battery compartment door back on.
For optimum performance, please place the Receiver away from metal and other sources of interference such as mobile phones, TVs, computers, appliances, etc. If the Receiver stops showing the display or dims, replace the batteries.
Set Up the Power, Installation & Make Settings for the Anemometer (Wind Gauge) and Wireless Remote Sensor
Installation/Mounting-- the first step is to select the location for the Anemometer that is outdoor and
not blocked on the top or sides so wind can freely reach it. The distance can be from 328ft (100m) to the Receiver or closer in an open area (the closer the better for transmission reception). The best location is usually on a mast on a roof or other high open position. The Wireless Sensor is built into the Anemometer.
Before mounting the Anemometer it is best to perform a transmission test where you install the batteries (new ones) in the Anemometer (see section below) to make sure all is ok and save a lot of time if you have to relocate the Anemometer.
Place the Anemometer horizontally in your selected outdoor location and install the batteries. Press and hold the “CHANNEL/SEARCH” button for a few seconds and you will see wind direction, temperature, and humidity icons flash on the display as the Receiver is now searching for remote sensors. If the readings for the outdoor information are shown within ten minutes, the transmission is successful and you can go ahead with the mounting. If the readings are not shown after ten minutes, then relocate the place you want to mount the Anemometer closer to the Receiver and remove the batteries and try the procedure again. Remove the batteries from the Anemometer prior to mounting and calibration.
Remove the four small screws (shown in above image) from the door of the Anemometer with a small screwdriver. Insert two AA batteries (user supplied) as indicated in the sensor (see right image above). Replace the door of the Anemometer by installing the four small screws to hold it in place.
To mount the Anemometer, you need a mast (user supplied) about 1 to 1.25” (2.54 to 3.1cm) in diameter and hardware to mount permanently in the location where you want to mount the Anemometer – see drawing below. Note that if you have an existing mast for mounting an antenna or similar device, you can mount the Anemometer on it. You should mount and ground a mast as directed in the instructions provided with the mast. If you do not have a mast, you can purchase them at aerial or antenna suppliers.
Place the U-shaped metal plates around the mast. Insert the four hex screws through the holes of the U-shaped plates and the holes on the Anemometer mounting bracket. The wind vane is to be above the metal bar of the Anemometer when it is in the horizontal position per the diagram below. Tighten the hex nut onto the hex screws.
MAST
NORTH
MAST
2
Calibrating & Installing the Batteries of the Anemometer
After mounting the Anemometer, you need to calibrate the wind direction so that the Anemometer properly measures the wind direction and transmits this information to the Receiver. Be sure the batteries have been removed from the Anemometer before the calibration. You will have to recalibrate the Anemometer whenever you replace the batteries.
Use the compass on the Anemometer and turn the wind vane so it is pointing due north (see drawing). Hold the wind vane pointing due north and install the batteries. The red LED above the battery door will flash a few times right after battery installation. Be sure the vane is pointing due north at the moment when the red LED flashes and then the calibration is completed. Replace the battery door. Press and hold the “CHANNEL/SEARCH” button a few seconds and the Channel 1 readings will appear within 10 minutes if the wireless sensor transmission is successful.
Set Up the Power and Installation of the Rain Gauge
Choose a mounting location for the Rain Gauge that is a flat and level surface 164ft (50m) or closer in an open area from the Receiver where data can be transmitted easily. The Rain Gauge should not be blocked on the top or sides so that rain can freely reach the gauge (do not put under an overhang or too close to a building or fence). Also, do not mount too close to the ground or to trees or plants.
To install the batteries in the Rain Gauge, turn it upside down (image below). Then, at the same time push the two clips (inside of the two large holes at the ends) inward and lift off the cover and battery compartment. Now turn the removed part upside down (image to the right) and pull out on the two clips of the battery cover. Insert two AA batteries (user supplied) per the polarity markings on the battery compartment. Then, replace the battery cover. Finally, replace the battery compartment and cover into the outer housing by aligning with the clips and then pushing down on the cover over the clips until they are secure.
Push and hold the “CHANNEL/SEARCH” button for a few seconds and the total rainfall will flash. The total rainfall reading should appear within two minutes. If no display for total rainfall after two minutes, then move the Rain Gauge closer and remove the batteries and repeat the above steps again.
Once the transmission to the Receiver is ok, then you are ready to mount the Rain Gauge. Hold the base of the Rain Gauge flat against the mounting surface and then use a level to make sure the Rain Gauge is horizontally level. Use a pencil to trace the inside of the mounting holes on the base of the Rain Gauge to mark the screw locations. Drill a hole in the center of each marked screw location and insert the supplied plastic screw plugs. Hold the Rain Gauge against the mounting surface so the holes on the base are aligned with the plastic screw plugs and then thread the supplied screws into each hole and use a screwdriver to tighten them.
3
Settings and Operation of the Receiver
Indoor & Outdoor Temperature & Humidity – the indoor temperature and humidity is shown
x
on the top right of the LCD display. Press the “CHANNEL/SEARCH” button to switch from indoor data to outdoor data (Channel 1). You can also have the indoor and outdoor information automatically switch about every five seconds when you push the “CHANNEL/SEARCH” button where you see an icon “CH ” that means in “switch” mode. When switching channels you may see Channel 2 with meaningless data and just ignore it.
x Data displayed in “C” or “F” – push the “C/F” button (rear of Receiver) to change from “C”
(Centigrade) or “F” (Fahrenheit) for the display you desire.
x Clock & Calendar – Press the “CLOCK” button and toggle between time, calendar
(day/month), and day of week. Press the CLOCK” button and hold down for a couple of seconds to enter the setup mode. Use the “UP” or “DOWN” buttons to make changes. Press the “CLOCK” after each setting is correct. The settings in sequence will be ĺ 12-24hr format/hour/minute/year/day-month sequence/month/day/exit. To check the time in another geographic zone, you first set the time differential in hours by pressing & holding the “ZONE” button on the rear of the Receiver to enter the set up. Then push the “UP” or “DOWN” buttons to change the hour differential and then push “ZONE” to accept. To check the alternate time zone just press the “ZONE” button.
x Max/Min Memory – press the button “MEMORY” to see the maximum temperature, humidity,
heat index, dew point, wind speed, and wind chill readings. Press the button again to see the minimum readings and press the button again to return to the normal mode. The memory will clear if you push and hold the “MEMORY” button for a few seconds when in the maximum or minimum readings.
x Barometer & Weather Forecast – the weather station has a built-in barometer to measure
atmospheric pressure and forecasts the weather with icons for Sunny/Partly Cloudy/Cloudy/Rainy/Stormy. The unit predicts the weather conditions for the next 12 to 24 hours based on the atmospheric pressure change and is about 70% correct. The company accepts no liability for any incorrect forecast.
If you do not live near sea level, the altitude must be set so that the air pressure will be accurate. Press the “PRESSURE” button to change the barometric pressure from hPa to inHg or mb/Hg. You can obtain your location air pressure from many internet weather stations (or local sources), to input the information, press and hold the “PRESSURE” button for a few seconds and then enter the correct data by using the up and down buttons.
The pressure history bar displays the moving atmospheric pressure history of the past 12 hours which allows reasonable tendencies.
4
x Heat Index – combines the effects of temperature and humidity and is the apparent temperature
of how hot the heat/humidity combination makes it feel. Push the button “Heat Index/Dew Point” to display either the heat index or the dew point.
x Dew Point – is the saturation point of the air, or the temperature to which the air has to be
cooled in order to get condensation. Push the “Heat Index/Dew Point” button to obtain the information the same way as noted above under “Heat Index”.
x Ice Alert – an ice alert icon (*) appears on the display next to the wind chill reading when the
outdoor temperature falls to or below 4° C (39.2° F).
x Wind Speed & Direction – the Anemometer allows you to sample the wind speed and
direction. Set the display to read the wind speed type by pushing the button on the rear of the Receiver called “WIND UNIT” to the choice you desire – kmp (kilometers per hour), mph (miles per hour), m/s (meters per second), knots, or Beaufort. The display shows 16 wind directions as “N” for north, “SW” for southwest, etc. and displays the average wind direction over a two minute period. Press the “WIND” button to select gust wind speed and it will show the maximum wind speed over a ten minute period and press the button again to show the average wind speed over a two minute period.
x Wind Chill – is the apparent temperature felt on exposed skin due to the combination of air
temperature and wind speed. The wind chill reading on the display is calculated based on the temperature measured by the Anemometer and the average wind speed.
x Wind Gust & Wind Chill Alarm – you can set the Receiver to sound an alarm for about one
minute when wind gust reaches or exceeds a set limit. Press the “WIND ALARM” button to silence the alarm sound but the related high alarm icons will continue to flash until the alarm condition is no longer met.
Press the “WIND ALARM” to show high wind gust alarm display and alarm icons appear in the wind gust area. Press and hold the “WIND ALARM” button to enter the setting mode and wind gust digits will flash. Use the up and down buttons to set the values you want and then press “WIND ALARM” to exit.
You can set the Receiver to sound an alarm for about one minute when the wind chill reaches or falls below the set limit. Press the “WIND ALARM” to silence the alarm sound. The related low alarm icon will continue to flash until the alarm condition is no longer met.
Press the “WIND ALARM” repeatedly until the alarm icon appears in the wind chill display area. Press and hold the “WIND ALARM” button to enter its setting mode and the wind chill digits will flash. Press the up and down buttons to set the values you want to use and press “WIND ALARM” to confirm the setting and exit.
Press the “WIND ALARM” button on the rear of the Receiver repeatedly to enable or disable the wind gust alarm or the wind chill alarm. When enabled, the Receiver will have icons of “Hi” and/or “Lo” for the functions.
x Rainfall Measurement – The wireless Rain Gauge provides daily, weekly, monthly and
accumulated rainfall measurements. Press the “RAIN/CLEAR” button repeatedly to switch between the different modes and the corresponding daily, weekly, monthly, or total icon will appear indicating your current display mode. In each mode, press and hold the “RAIN/CLEAR” button for a few seconds to clear the readings. Press the “RAIN UNIT”
button on the rear of the
Receiver to change the rain measurement unit between mm and inch to your choice.
x Rainfall History – the Receiver has a large capacity memory that can store and display – daily
rainfall (up to the last six day s as wel l as the cur rent day), weekly rainfa ll (up to the last six weeks as well as the current week), and monthly rainfall (up to the last six months as well as the current month).
5
Press “RAIN HISTORY” repeatedly to scroll through the history data corresponding to your selection. On the bar shown in the rainfall display area, the “0” represents the current period and the “-1”, “-2”, etc. indicate the prior periods. As an example, during the month of April, press the “RAIN HISTORY” button repeatedly in the monthly mode until “-3” bar chart is shown. The bar chart and reading indicate the monthly rainfall record for the month of January
st
through 31st).
(1
x Alarm Setting – press the “ALARM” button to show the alarm time and the “ALARM” icon
will appear. Press again to enable or disable the alarm – when enabled a bell icon will appear”. Press and hold the “ALARM” button to enter the setting mode. Enter the desired hour and minute values by pressing the “UP” and “DOWN” button and then pressing “ALARM” to set each.
x Snooze – when the alarm goes off, press
“SNOOZE/LIGHT” button (rear of Receiver) to go into snooze mode and the alarm will go off again in 10 minutes and continue over and over as long as you hit the “SNOOZE”. To stop the snooze or alarm, press the “ALARM” button.
x Channel – if your Sensor is set correctly to Channel 1, then a small icon to the left of wind chill
display will show “ch1”. If you do not have an outdoor temperature and humidity display, make sure that the “1” is displayed and if not (shows a 2 or 3), then push the “CH” button until is shows the “1”.
x Low Battery Indication – the Receiver and remote sensors will be display an icon and you
should change batteries as soon as possible.
x Placement – the Receiver can be put on a table, desk, or other flat surface or it can (by using a
hanger cut out (in two places) on the rear of the Receiver) be hung on a wall or other location.
Specifications:
x Indoor Temperature Range = 0º to +50º C (+ 32º to + 122º F) x Remote Sensor Temperature Range = -20º to + 60º C ( -4º to + 140º F) x Indoor/Outdoor Humidity Range = 20% to 99% Relative Humidity x Resolution = ± .5º C (± 1.5º F) for temperature & ± 1.5% humidity x Wind Speed Range = 0 to 108 km/h, 0 to 67 mph, 0 to 30 m/s, 0 to 58 knots, 0 to 11 Beaufort x Rain Gauge Reading = 0 to 9999mm, 0 to 394 in x Clock = digital quartz x Transmission = RF433 MHz x Dimensions = Receiver – 7.6” x 1.1” x 4.5” (193x28x114mm) Anemometer/Sensor – 8.0” x 7.8” x
14.3” (203x198x363mm) Rain Gauge – 5.8” x 2.3” x 3.3” (147x58x84mm)
x Weight = Receiver - 15oz/425g Sensor - 9oz/255g Rain Gauge - 6oz/170g
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER AUTHORITY TO OPERATE THE EQUIPMENT
interference that may cause undesired operation.
2835 Columbia St. Torrance, California 90503 U.S.A.
www.celestron.com
Printed in China 0110
RoHS
Persönliche Wetterstation
mit drahtlosen Sensoren
für Temperatur und
Luftfeuchtigkeit/Windges
chwindigkeit/Regen
Modell 47009
Vielen Dank für Ihren Kauf dieser persönlichen Wetterstation von Celestron. Bitte lesen Sie vor dem Gebrauch die Bedienungsanleitung. Wir hoffen, dass Sie viele Jahre damit zufrieden sein werden.
Schieben Sie das Fußteil unten im Empfänger so weit ein, bis Sie ein Klicken hören. Die richtige Position ist in den Fotos und unten gezeigt. Wenn Sie den Empfänger an einer Wand (oder anderen flachen Oberfläche) aufhängen wollen, entfernen Sie nach der Einrichtung das Fußteil und lesen Sie die Informationen unter dem Punkt „Aufstellung“ auf der letzten Seite.
DEUTSCH
Sie benötigen die folgenden Werkzeuge und Hilfsmittel zur Installation des Anemometers und der Regenmesser: kleinen Kreuzschlitzschraubendreher, 5 mm (3/16 Zoll) Sechskantschlüssel, Bohrmaschine, Wasserwaage, Bleistift und Mast.
Stromversorgung des Empfängers
Öffnen Sie die Batteriefachtür auf der Rückseite des Empfängers (oben in der Mitte des Fotos links) und legen Sie sechs AA-Batterien (nicht im Lieferumfang enthalten) ein, wie durch die Polaritätssymbole im Batteriefach angezeigt (siehe Foto rechts). Legen Sie dann die Batteriefachtür wieder an.
Um seine optimale Leistung sicherzustellen, stellen Sie den Empfänger nicht in der Nähe von Metall oder anderen Störungsquellen, z.B. Handys, Fernsehgeräten, Computern, Haushaltsgeräten, auf. Die Batterien müssen ersetzt werden, wenn der Empfänger nichts mehr anzeigt oder die Anzeige schwächer wird.
Leistungseinstellungen, Installation und Konfiguration der Typeinstellungen des Anemometers (Windmessers) und des drahtlosen Fernsensors
Installation/Anbringung—Der erste Schritt ist die Auswahl des Standorts für das Anemometer. Er muss
sich draußen befinden und darf nicht oben oder seitlich blockiert sein, damit es der Wind ungehindert erreichen kann. Die maximale Entfernung vom Empfänger ist 100 m (328 Fuß) in einem offenen Bereich (je dichter am Empfänger, desto besser der Empfang der übertragenen Daten). Der beste Standort ist in der Regel ein Mast auf einem Dach oder ein anderer höherer offener Standort. Der drahtlose Sensor ist im Anemometer integriert.
Vor der Installation des Anemometers empfiehlt es sich, einen Übertragungstest durchzuführen. Legen Sie dazu die (neuen) Batterien im Anemometer ein (siehe Abschnitt unten), um die ordnungsgemäße Funktion sicherzustellen. Damit sparen Sie sich viel Zeit, falls Sie das Anemometer verlegen müssen.
Platzieren Sie das Anemometer horizontal an Ihrem ausgewählten Standort im Freien und legen Sie die Batterien ein. Drücken und halten Sie die Taste „CHANNEL/SEARCH“ (KANAL/SUCHE) für ein paar Sekunden gedrückt. Daraufhin blinken die Symbol e für Windric htung, Te mperatur und Luftfeu chtigkeit auf dem Display auf, während der Empfänger nun Fer nsen soren ortet . Wenn die Mess werte für die Auß endat en innerhalb von zehn Minuten angezeigt werden, ist die Übertragung erfolgreich, und Sie können die Installation in Angriff nehmen. Wenn nach zehn Minuten keine Messwerte angezeigt werden, wählen Sie einen anderen Installationsort für das Anemometer in geringerem Abstand vom Empfänger. Nehmen Sie die Batterien heraus und probieren Sie das Verfahren noch einmal aus. Nehmen Sie vor der Installation und Kalibrierung die Batterien aus dem Anemomet er.
Entfernen Sie die vier kleinen Schraube n (siehe Foto oben) an der Tür des Anemometers mit einem kleinen Schraubendreher. Legen Sie zwei AA-Batterien (nicht im Lieferumfang enthalten) ein, wie im Sensor angezeigt (siehe Foto rechts oben). Legen Sie die Tür des Anemometers wieder an, indem Sie die vier kleinen Schrauben wieder eindrehen.
Zur Installation des Anemometers benötigen Sie einen Mast (vom Benutzer bereitgestellt) mit einem Durchmesser von ca. 2,5 bis 3,0 cm (1 bis 1,25 Zoll) sowie Befestigungsmittel zur permanenten Installation des Anemometers an der gewünschten Stelle – siehe Zeichnung unten. Ein bestehender Mast zur Anbringung einer Antenne oder einer ähnlichen Vorrichtung bietet sich zur Installation des Anemometers an. Der Mast ist entsprechend seiner Anleitung zu instal liere n und v era nke rn. We nn Sie k einen M ast ha ben , können Sie einen beim Ante nnenhä ndler kaufen .
Legen Sie die U-förmigen Metallplatten um den Mast. Stecken Sie die vier Sechskantschrauben durch die Löcher in der U-förmigen Platte und die Löcher in der Anbauplatte des Anemometers. Die Windfahne muss sich über der Metallschiene des Anemometers befinden, wenn sie sich entsprechend dem nachstehenden Diagramm in horizontaler Position befindet. Ziehen Sie die Sechskantmutter auf den Sechskantschrauben an.
MAST
NORDEN
MAST
2
Kalibrierung und Einlegen der Batterien des Anemometers
Nach der Installation des Anemometers müssen Sie die Windrichtung kalibrieren, so dass das Instrument die Windrichtung richtig misst und diese Daten korrekt an den Empfänger überträgt. Achten Sie darauf, dass die Batterien vor der Kalibrierung aus dem Anemometer entfernt wurden. Das Anemometer muss bei jedem Ersatz der Batterien neu kalibriert werden.
Orientieren Sie sich am Kompass des Anemometers und drehen Sie die Windfahne, so dass sie nach Norden zeigt (siehe Zeichnung). Belassen Sie die Windfahne in der Nordrichtung und legen Sie die Batterien ein. Die rote LED über der Batterietür blinkt nach dem Einlegen der Batterien einige Male auf. Achten Sie darauf, dass die Windfahne in dem Moment des Aufleuchtens der roten LED in Richtung Norden zeigt. Nun ist die Kalibrierung beendet. Legen Sie die Batteriefachtür wieder an. Drücken und halten Sie die Taste „CHANNEL/SEARCH“ (KANAL/SUCHE) einige Sekunden lang gedrückt. Innerhalb von 10 Minuten werden dann bei erfolgreicher Übertragung des drahtlosen Sensors die Messwerte von Kanal 1 angezeigt.
Leistungseinstellungen und Installation des Regenmessers
Wählen Sie als Installationsort für den Regenmesser eine flache, glatte Oberfläche im Abstand von max. 50 m (164 Fuß) vom Empfänger in einem offenen Bereich, von dem die Daten leicht übertragen werden können. Der Regenmesser sollte oben oder seitlich nicht blockiert sein, so dass Regen ungehindert auf das Gerät treffen kann (nicht unter einem Überhang oder zu dicht an einem Gebäude oder Zaun installieren). Auch nicht zu dicht am Erdboden oder an Bäumen oder Pflanzen installieren.
Drehen Sie den Regenmesser um (siehe Foto unten), um die Batterien einzulegen. Drücken Sie dann die beiden Klemmen (im Innern der beiden großen Öffnungen an den Enden) gleichzeitig nach innen und heben Sie die Abdeckung und das Batteriefach heraus. Drehen Sie jetzt das entfernte Teil um (siehe Foto rechts) und ziehen Sie die beiden Klemmen der Batteriefachabdeckung nach außen. Legen Sie zwei AA­Batterien (nicht im Lieferumfang enthalten) entsprechend der auf dem Batteriefach angegebenen Polarität ein. Legen Sie dann die Batteriefachabdeckung wieder an. Setzen Sie dann das Batteriefach und die Abdeckung wieder im Außengehäuse ein, indem Sie sie mit den Klemmen ausrichten und dann die Abdeckung über den Klemmen fest andr ücken.
Drücken und halten Sie die Taste „CHANNEL/SEARCH“ (KANAL/SUCHE) einige Sekunden lang gedrückt. Daraufhin blinkt die Gesamtniederschlagsmenge auf. Die Angabe für die Gesamtniederschlagsmenge sollte innerhalb von zwei Minuten angezeigt werden. Wenn nach zwei Minuten keine Gesamtniederschlagsmenge angezeigt wird, verringern Sie den Abstand des Regenmessers und nehmen Sie die Batterien heraus, um die vorstehenden Schritte noch einmal zu wiederholen.
Nach erfolgreicher Übertragung an den Empfänger können Sie die Installation des Regenmessers in Angriff nehmen. Halten Sie das Unterteil des Regenmessers flach an die Installationsfläche und stellen Sie mit einer Wasserwaage sicher, dass der Regenmesser horizontal waagerecht ist. Ziehen Sie mit einem Bleistift die Befestigungslöcher am Unterteil des Regenmessers nach, um die Schraubenpositionen zu markieren. Bohren Sie in der Mitte jeder markierten Schraubenposition ein Loch und stecken Sie die im Lieferumfang enthaltenen Kunststoff-Verschlussschrauben ein. Halten Sie den Regenmesser so an der Befestigungsoberfläche an, dass die Löcher am Unterteil mit den Kunststoff­Verschlussschrauben ausgerichtet sind. Schrauben Sie dann die mitgelieferten Schrauben in jedes Loch ein und ziehen Sie sie mit einem Schraubendreher fest.
3
Loading...
+ 21 hidden pages