DANGER
!
Improper installation, adjustment, alteration, service, or maintenance can cause
property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
!
DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
After installation of this equipment, immediately contact your local gas
supplier to obtain information about what action to take whenever any
person smells gas. Post this information in a prominent location.
Keep this Manual in a Convenient Location for Reference
VISIT ANETS AT www.anets.us
FOR YOUR SAFETY
!
WARNING
Price $20.00 US
Form I-205;
Rev. 6/05
1
CONTENTS
Code Requirements ...................................................................... 2
Shipping Container Inspection ....................................................... 3
Griddle Gas Supply Specifications................................................. 3
Installation Requirements............................................................... 4
Gas Connection Instructions.......................................................... 4
Griddle Operating Instructions....................................................... 4
Lighting Procedure.................................................................. 5
Griddle Preparation For Use ......................................................... 5
Shutdown Procedure .................................................................... 5
Daily Cleaning Procedure............................................................... 6
Monthly Maintenance Instructions .................................................. 6
Griddle Troubleshooting Guide ....................................................7-8
Griddle W arranty ........................................................................... 8
CODE REQUIREMENTSCODE REQUIREMENTS
CODE REQUIREMENTS
CODE REQUIREMENTSCODE REQUIREMENTS
IMPORTANT: Read the Code Requirements and the Installation Requirements and Instructions carefully, before
starting the installation. Contact ANETS (800-837-2638) if any problems or questions arise.
The griddle installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 (latest edition); the Natural Gas Installation Code, CAN/CGA-B149.1 (latest edition); or the Propane
Gas Installation Code, CAN/CGA-B149.2 (latest edition), as applicable,
including:
(a) Disconnect the griddle at its individual shutoff valve from the gas supply piping system during any pressure testing
of the gas supply system at test pressures in excess of ½ psig (3.45 kPa).
(b) Isolate the griddle from the gas supply piping system during any pressure testing of the gas supply system at test
pressures equal to or less than ½ psig (3.45 kPa).
(c ) For griddles utilizing the optional stand with casters, the griddle installation shall be made with a connector that
complies with the Standard for connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition) or CAN/CGA
6.16 (latest edition), and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices
for Use with Gas Fuel, ANSI Z21.41 or CAN/CGA 1-6.9 (latest edition). Restrict the movement of a griddle on a
caster-equippped stand by using a limiting device (for example, a cable attached both to the griddle and to a fixture
attached to the site structure) to avoid depending on the connector and the quick-disconnect device or its associated piping to limit griddle movement.
(d) The regulator supplied with the unit should be installed in the inlet gas supply line with the arrow on the regulator
pointing in the direction of the gas flow .
(e ) Install this griddle on a non-combustible cabinet or stand with its back and sides at least 6” away from any combus-
tible wall.
!
WARNING
Install this griddle under a ventilation hood that conducts combustion products outside the building. Venting must
comply with ANSI/NFPZ 96 (latest edition).
(f ) Install this griddle in a location where adequate combustion and ventilation air is available. Keep the area directly in
front of the griddle open for adequate air flow to the burners. DO NOT obstruct the flow of combustion and
ventilation air.
(g) Keep the griddle area free and clear from combustibles and debris.
2
SHIPPING CONTSHIPPING CONT
SHIPPING CONT
SHIPPING CONTSHIPPING CONT
AINER INSPECTIONAINER INSPECTION
AINER INSPECTION
AINER INSPECTIONAINER INSPECTION
1. Carefully examine the shipping container for external damage. When damage is noted, notify the
delivery carrier immediately. Save all packing materials for damage claim examination.
2. If no external damage is noted, remove the shipping container from the griddle and examine the griddle
carefully for damage. Place the griddle in a safe location,
claims adjuster can examine the griddle.
NOTE: A Parts List for each ANETS Griddle is among the items shipped with each griddle. If an additional
copy of this list is needed, please contact the factory as directed on the back cover.
if damage is noted, so that the freight damage
GRIDDLE GAS SUPPLY SPECIFICATIONS
Please make sure that your desired griddle location has gas
supply factors that are suitable for this product:
Natural Gas Propane Gas
MANIFOLD PRESSURE*
SUPPLY PRESSURE***
4“ W.C. **
6“ W.C., minimum
10“ W.C.
11“ W.C., minimum
* - Measured at tap near left end of gas manifold.
** - W.C. = Inches, Water Column.
*** - Measure supply pressure ahead of pressure regulator when all other gas-powered
equipment is operating.
Refer to the specification plate on the griddle to identify the BTUH input for your specific model.
IMPORT ANT NOTE: BTU/Hr Ratings are based on sea level operation. For sites above 2000 feet, reduce this rating
4% for each 1000 feet above sea level.
Gas Supply Inlet Pipe must be ¾” NPT (National Pipe Thread) standard gas line. The gas supply inlet line should be as
straight as possible (fewest bends or elbows) to obtain the highest available gas pressure at the appliance.
NOTE: Using a flexible inlet line permits variation in the gas supply line location, both horizontally and
vertically.
Anets griddles are only for use with the type of gas specified on the spec plate. If a griddle requires modification to use a
gas other than that which is identified on the griddle spec plate, contact your ANETS representative or call (800) 837-2638.