Anest Iwata W101-AS User Manual

71.5d B
(A)
Spray condition
Recommended
Main specifications
List
1
20
2
21
22
1
23
25
24
5
6
7
8
9
11
13
14
15
17
18
19
◆ ◆ ◆ ◆ ◆ ◆ ◆
INSTRUCTION MANUAL
和文取説は、裏面にあります
Spray Gun with Agitator Cup
W-101A
This manual contains IMPORTANT WARNINGS andINSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation and correct handling.
Read and understand the instruction manual, before use and retain for
reference.
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following   marked items which are especially important.
Important specifications
Max. Pressure
Measuring point
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the minimum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and safety as well as your own company regulations.
0.68 MPa / 6.8 b a r / 98 PSI
1m backwards from gun , 1.6 height
Max. Temperature
Atmosphere AirFluid 5℃〜43℃
5℃〜40℃
Model
W-101A-104G W-101A-134G W-101A-134S Suction
1. Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows
2. Tested with 12 sec./NK-2 automotive repair paint
■Parts
Air cap set 1 Fluid nozzle-fluid
needle set
2-1 Fluid nozzle 1 2-2 Fluid needle set 1
Needle packing set 1
Body set 1 5-1 Air nipple 1 5-2 Fluid nipple 1
Pattern adj. set 1 6-1 Stopper 1 6-2 Washer 1 6-3 Back ring 1
Air valve seat set 1 7-1 O ring 1
Air valve 1
Air valve spring 1
Fluid needle spring 1
Air valve shaft 1
Air adj. set 1
Trigger stud 1
16 Trigger 1
E stopper 1
Brush 1
Instruction manual 1
Marked parts are wearable parts.
Type of
feed
Gravity
Description Q’ty
Nozzle
orifice
φmm(in)
1.0 (0.039)
1.3 (0.051)
1
Air cap
W-101
1 Atomizing
air pressure
set
H4
bar (PSI)
1.5 (21)
Tube 1 Air motor lid set 1
Container (for suction feed)
or cup (for gravity feed) Fluid adj. set 1 Air adj. set for air motor 1
output
ml/min
Description Q’ty
Fluid
90 165(6.5) 110 180(7.1) 100
Air
consumption
l/min(cfm)
180 (6.4)
Pattern
Width
mm(in)
170(6.7)
Air & fluid
Connection
(Air)G1/4(NPS1/4)
(Fluid)G1/4(NPS1/4)
Weight
g(lbs)
695(1.53) 775(1.71)
Remarks
With
agitator
cup
- 1 -
Safety precautions
Fire and explosion
1. Spark and open flames are strictly prohibited.
Paints can be highly flammable and can cause fire. Avoid any ignition sources such as smoking, open flames, electrical goods, etc.
2. Never use the following HALGOGENATED HYDROCARBON SOLVENTS
which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.
unsuitable solvents:methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride,  (Be sure that all fluids and solvents are compatible with gun parts.
We are ready to supply a material list used in the product
3. Securely ground spray gun by using air hose with built-in ground wire. Ground wire : Less than MΩ. Check the earth stability periodically .
If not, insufficient grounding can cause fire and explosion due to static electric sparking.
Improper use of equipment
1. Never point gun toward people or animal.
If done, it can cause inflammation of eyes and skin or bodily injury.
2. Never exceed maximum operating pressure and maximum operating Temperature.
3. Be sure to release air and fluid pressures before cleaning, disassembling or servicing.
If not, remaining pressure can cause bodily injury due to improper operation or scattering cleaning liquid. In order to release pressure, first stop supply of compressed air, fluid and thinner to spray gun. Then remove trigger toward you.
4. Tip of fluid needle set has a sharp point. .
Do not touch the tip of fluid needle during maintenance for the protection of the human body.
Protection of human body
1.Use in a well-ventilated site by using spray booth.
If not, poor ventilation can cause organic solvent poisoning and catch fire.
2.Always wear protective gear (safety glasses, mask, gloves).
If not, cleaning liquid, etc., can cause inflammation of eyes and skin. If you feel something wrong with eyes or skin, immediately see a doctor.
3.Wear earplugs if necessary.
Noise level can exceed 85dB(A), depending on operating conditions and painting site
4.If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome. Be sure to take a rest if you feel tired.
Other precautions
1.Never alter this spray gun.
If done, it can cause insufficient performance and failure.
2.Enter working areas of other equipment (robots, reciprocators, etc.) after machines are turned off.
If not, contact with them can cause injury.
3.Never spray foods or chemicals through this gun.
If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter.
4.If something goes wrong, immediately stop operation and find the cause. Do not use again until you have solved the problem.
trichloroethylene, 1.1.1-trichloroethane
How to connect
-Use clean air filtered through air dryer and air filter.・・・If not, dirty air can cause painting failure.
-If you use this gun for the first time after purchasing, clean fluid passages spraying thinner and remove rust preventive oil.
If not, remaining preventive oil can cause painting failure such as fish eyes.
-Firmly fix hose or container to spray gun.・・・If n ot, disconnection of hose and drop of container can cause bodily injury.
Job1. Connect an air hose to air nipple tightly. Job2. Connect a fluid hose or a container to fluid nipple tightly. Job3. Flush the gun fluid passage with a compatible solvent. Job4. Pour paint into container, test spray and adjust fluid output as well as pattern width
- 2 -
×
5.Loosen fluid adj. screw 5/8 of a turn (225
) counterclockwise
.
How to operate
Suggested air pressure is 1.5 to 2.0 bar (21 to 29 PSI). Recommended paint viscosity differs according to paint property
and painting conditions. 12 to 18 sec. / Ford cup#4 is recommendable.
Keep fluid output as small as possible to the extent that the job will not be hindered. It will lead to better finishing with fine atomization.
The gun should be held so that it is perpendicular to the surface of the work piece at all times. Then, the gun should move in a straight and horizontal line. Arcing the gun causes uneven painting.
100200 mm
(7.99.8 in)
Set the spray distance from the gun to the work piece as near as
possible within the range of 100200 mm (7.99.8 in).
Maintenance
and inspection
-First release air and pressure fully according to item No. 3 of “Improper use of equipment” of WARNING on page 2.
-Tip of fluid needle set has a sharp point. Do not touch the tip of needle valve at the maintenance for protection of the human body.
-Be careful not to damage the tip of fluid nozzle or must not put your hand on it.
-Only an experienced person who is fully conversant with the equipment can do maintenance and inspection.
-Never use commercial or other parts instead of ANEST IWATA original spare parts.
-Never immerse the whole gun into liquid such as thinner.
-Never soak air cap set in solvent for extended period even if cleaning. It may cause defective pattern.
-Never damage holes of air cap a fluid nozzle and fluid needle.
Step-by-step procedure
1.Pour remaining paint to another container. Clean fluid passages and air cap set.. Spray a small amount of thinner to clean fluid passages.
2.Clean each section with brush soaked with thinner and wipe out with waste cloth.
3. Before disassembly, fully clean fluid passages. 3. During disassembly, do not scratch seat section.
(1)Disassemble fluid nozzle.
Use ring spanner, box wrench or optional exclusive spanner (code 03538600)
to remove fluid nozzle.
(2)Disassemble fluid needle set.
You do not need to remove fluid adj. guide set from gun body. Remove fluid adj. knob and fluid needle spring, and then pull out fluid needle spring, and then pull out fluid needle set from back of fluid adj. guide set..
4. When you want to adjust fluid needle packing set, first tighten it by hand while fluid
needle set remains inserted. Then tighten it further about 1/6 turn (60-degree) by spanner.
When you remove needle packing set, do not leave plastic piece of needle packing
set in the gun body.
5.In order to assemble air valve, first assemble air valve & air valve spring & fluid adj.
guide set together. Next, insert fluid needle set into fluid adj. guide set , then fit it to gun body set and screw fluid adj. guide set.
6.Turn pattern adj. knob or air adj. knob counterclockwise to fully open. And then
tighten pattern adj. set or air adj. set..
1. Each hole passage of air cap and fluid nozzle Replace if it is crushed or deformed.
2. Packing and O ring Replace if it is deformed or worn out.
3.Leakage from seat section between fluid nozzle and fluid needle set Replace them if leakage does not stop after fully cleaning fluid nozzle and fluid needle set.
NOTE:HOW TO ASSEMBLE FLUID ADJ.SET.
1.Assemble fluid adj. guide to body set tightly.
2.Insert scale plate into fluid adj. guide.
3.Match 3 on the scale plate up to the gun top and then tighten Hex. Nut.
Where to inspect Parts replacement standard
If you replace fluid nozzle or fluid needle set only, fully match them and confirm that there is no leakage.
How to lock fluid adj. knob
4.Turn fluid adj. screw clockwise to the end.
1. Incomplete cleaning can fail pattern shape and uniform particles. Especially clean fully and promptly two-component paint after use.
2. Soaking whole automatic spray gun in solvent may cause automatic spray gun malfunction.
Also soaking air cap set itself for extended period. When cleaning, never scratch each hole of air cap set and fluid nozzle, and fluid needle set.
(1)Remove fluid nozzle after removing fluid needle set or while keeping fluid needle pulled, in
order to protect seat section.
(2) Be careful when handing tip of fluid needle set since it is sharp.
Disassemble fluid adj. guide set as little as possible.
4. If you tighten fluid needle packing set too much, fluid needle set will not move smoothly,
resulting in paint leakage from tip of fluid nozzle. Try to adjust it carefully while pulling trigger and confirming movement of fluid needle set. When you tighten it too much, first fully loosen it and then tighten it again carefully.
5. If you try to fit air valve spring and air valve to gun body set without fluid needle set, air valve will not be fitted correctly and lop packing inside fluid adj. guide set will be damaged.
6. If pattern adj. Knob or air adj. Knob is not fully opened, tip of it can contact and damage fluid nozzle and cause seizure of thread.
6.Insert fluid adj. knob into fluid adj. screw.
7.Screw fluid adj. lever while matching the lever to
- 3 -
Parts list
When ordering parts, specify gun’s model, part name with ref. No. and marked No. of air cap set, fluid nozzle and fluid needle. When replacing fluid nozzle or/and fluid needle for pressure feed application, please order nozzle needle set.
Troubleshooting
Spray Pattern Problems Remedies
1. Air enters between fluid nozzle and tapered seat of gun body.
Fluttering
Crescent
Inclined
Split
Heavy Center
Spit
2. Air is drawn from fluid needle packing set..
3.Air enters at fluid container fitting nut or fluid hose joint.
1. Paint buildup on air cap partially clogs horn holes. Air pressure from both horns differs.
1. Paint buildup or damage on fluid nozzle circumference and air cap center.
2. Fluid nozzle is not properly fitted.
1. Paint viscosity too low.
2. Fluid output too high.
1. Paint viscosity is too high.
2. Fluid output is too low.
1. Fluid nozzle and fluid needle set are not seated properly.
2.The first-stage travel of trigger(when only air discharges) decreases.
3. Paint buildup inside air cap set.
Fluid nozzle-fluid needle set combination
Fluid nozzle Fluid needle set
Orifice φmm(in) Mark Mark
φ1.0 (0.039) W101/T10 φ1.3 (0.051) W101/13 10013
1. Remove fluid nozzle to clean seat. If it is damaged, replace nozzle.
2. Tighten fluid needle packing.
3. Fully tighten joint section.
1. Remove obstructions from horn holes with attached brush. But do not use metal objects to clean horn holes.
1. Remove obstructions.
Replace if damaged.
2. Remove fluid nozzle and clean seat section.
1. Add paint to increase viscosity.
2. Tighten fluid adj. knob to reduce fluid output.
Or turn pattern adj. valve set clockwise.
1. Add thinner to reduce viscosity.
2.Turn fluid adj. valve knob counter-clockwise to increase fluid output.
1. Clean or replace fluid nozzle and fluid needle set.
2. Replace fluid nozzle and fluid needle set.
3. Clean air cap set.
10008
Problem
Air leaks
(from tip of air cup)
Paint leaks
Paint does not
come out
Where it
occurred
Airvalve set
Fluid nozzle
Fluid needle
Tip of gun
R1:retighten R2:adjust R3 : clean R4 : replace parts
Parts to be checked Cause
Air valve * Dirt or damage on seat
Air valve seat set O ring * Damage or deteriorated
Fluid nozzle fluid needle set
Fluid nozzlegun body
Fluid needlepacking set
Needle packing setneedle set
Packing seat * Insufficient tightening Fluid adj. knob * Insufficient opening Tip hole of nozzle * Clogged Paint filter * Clogged
* Dirt or damage on seat * Wear on air valve spring
* Dirt, damage, wear on seat * Loose fluid needle adj. knob * Wear on needle spring * Insufficient tightening
* Dirt or damage on seat * Needle does not return due to packing set too tight * Needle does not return due to paint buildup on fluid needle
* Wear
R1 R2 R3 R4
○ ○ ○
Remedy
○ ○
○ ○
○ ○
3176,Shinyoshida-cho,Kohoku-Ku, Yokohama223-8501,Japan
ManualNo.T033-05 CodeNo.03741612
- 4 -
Loading...