19-7, Kamata 4-chome, Ota-ku, Tokyo, 144-0052 Japan Phone: +81(0)3 3733 1151 Fax: +81(0)3 3739 7310
HEADQUARTERS: 2021 N. Capitol Avenue, San Jose, CA 95132, U.S.A. Phone: +1 408 941 0100 Fax: +1 408 941 0103
EAST OFFICE: 7617 Standish Place, Rockville, MD 20855, U.S.A. Phone: +1 301 294 3365 Fax: +1 301 294 3359
HEADQUARTERS: “Vijverdam”, Dalsteindreef 57, 1112XC Diemen, The Netherlands Phone: +31(0)20 698 1441 Fax: +31(0)20 699 8938
NIEDERLASSUNG DEUTSCHLAND: Nymphenburger Straße 119 B, D-80636 München, Germany Phone: +49(0)89 143 8150 Fax: +49(0)89 143 81555
19 Kim Keat Road #05-03, Jumbo Industrial Building, Singapore 328804 Phone: +65 251 1391 Fax: +65 251 1987
7F-1, No. 346 Pei-Ta Road, Hsin Chu, Taiwan Phone: +886 35 28 4168 Fax: +886 35 28 4110
Please visit our website for more information:
www.ando.com
Specifications are subject to change without notice.
KT-1806-2 9910 KL230
Printed in Japan
Specifications
Applicable fibers SM, GI (50/125 µm)
Measurement wavelength range1)600 to 1750 nm
Wavelength accuracy
1, 3)
±0.05 nm (1510 to 1580 nm, after calibration
with built-in reference light source)
±0.5 nm (600 to 1750 nm)
Wavelength linearity
1, 3)
±0.01 nm
(1510 to 1580 nm, resolution setting: 0.01 nm)
Wavelength repeatability
1, 3)
±0.005 nm (1 min.)
Wavelength resolution
1, 3)
Max. resolution: 0.015 nm or better
(1510 to 1580 nm, resolution setting: 0.01 nm)
Resolution setting: 0.01, 0.02, 0.05, 0.1, 0.2,
0.5, 1.0, 2.0 nm
Resolution accuracy
1, 3)
±5 %: (1300 to 1650 nm, resolution: 0.05 nm
or more, resolution correction: ON)
Measurement level range
2, 3)
-90 to +20 dBm (1200 to 1650 nm, sensitivity: HIGH3)
-80 to +20 dBm (600 to 1200 nm, sensitivity: HIGH3)
-60 to +20 dBm (600 to 1750 nm, sensitivity: HIGH3)
Level accuracy
2, 3)
±0.3 dB (1310/1550 nm, input: -30 dBm,
sensitivity: HIGH 1-3)
Level linearity
2, 3)
±0.05 dB (Input: +10 to -50 dBm,
sensitivity: HIGH 1-3)
Level flatness
2, 3)
±0.1 dB (1510 to 1580 nm)
Polarization dependency
2, 3)
±0.05 dB (1550 nm), ±0.05 dB typ.(1310 nm)
Dynamic range
3)
60 dB (1523 nm, peak: ±0.2 nm,
resolution: 0.01 nm)
70 dB (1523 nm, peak: ±0.4 nm,
resolution: 0.01 nm)
Sweep time Approx. 500msec. (Span: 100 nm or less,
sensitivity: NORMAL HOLD, ave.: 1,
501 samples, resolution correction: OFF)
Function Automatic Program function (20 programs, 200 steps),
measurement Long-term measurement function
Setting of Span setting: 0 to 1200 nm
measuring Measuring sensitivity setting: NORMAL
conditions HOLD/AUTO, HIGH 1/2/3
Number of averaging setting: 1 to 1000 times
Sample number setting: 11 to 20001, AUTO
Automatic setting function of measuring
conditions
Sweep-between-marker function
0nm sweep function
Pulse light measurement function
Air/vacuum wavelength measurement
function
TLS synchronized measurement function
Trace display Level scale setting: 0.1 to 10 dB/div, linear
Simultaneous display of 3 independent traces
Max./Min. hold display
Roll averaging display
Calculation-between-traces display
Normalized display
Notes
1) Horizontal scale: wavelength display mode
2) Vertical scale: absolute power display mode, resolution: 0.05 nm or more,
resolution correction: OFF
3) At 23±3 °C, with 10/125 µm single mode fiber, after
2 hours of warm-up.
Function Trace display Curve-fit display
3D display
Split display
Power density display, % display,
dB/km display
Frequency display of horizontal axis scale
Data analysis WDM waveform analysis (Wavelength/
Level/SNR list display)
Optical fiber amplifiers analysis (GAIN/NF),
PMD analysis
DFB-LD analysis, FP-LD analysis, LED
analysis, SMSR analysis
Peak search, bottom search, spectral
width search, notch width search
Delta marker (max. 100), line marker
(analysis range specification)
Graph display of long-term measurement
results
Others Self-wavelength calibration function (using
built-in reference light source)
Wavelength/Level compensation function,
label function, help function
Memory Built-in FDD 3.5-inch 2HD
File format Trace file, program file, measuring
conditions file
Text file (trace, analysis data, etc.)
Graphics file (BMP, TIFF)
Internal memory
32 traces, 20 programs
Data output Printer Built-in high speed printer
Interface
Remote control G
P-IB (2 ports)
TLS control interfaces (TTL)
Others Sweep trigger input (TTL)
Sample enable input (TTL)
Sample trigger input (TTL)
Analog output (0 to 5V)
Video output (VGA)
Display 9.4-inch color LCD
(Resolution: 640 x 480 dots)
Optical connector FC (Standard)
Power requirements AC 100 to 120/200 to 240 V, 50/60 Hz,
approx. 200 VA
Environmental conditions Operating temperature: 5 to +40 °C
Storage temperature: -10 to +50 °C
Humidity: 80 %RH or less (No condensation)
Dimensions and mass Approx. 425(W) x 222(H) x 450(D) mm
Approx. 30 kg