Anden A130 Installation And Operating Instructions Manual

Model A130 Dehumidifier
Installation and Operating Instructions
ON/OFF BUTTON
USED TO TURN
DEHUMIDIFIER ON
AND OFF
MODE BUTTON USED
FOR OPTIONAL
VENTILATION FEATURE
UP/DOWN BUTTONS USED TO CHANGE HUMIDITY
DEHUMIDIFER CONTROL
INLET FILTER ACCESS DOOR DRAIN POWER
OUTLET
SWITCH
SAFETY INSTRUCTIONS
WARNING
1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
3. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
CAUTION
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed by a qualified service
technician.
3. Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5. Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6. Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower
indoor humidity in the winter.
READ AND SAVE THESE INSTRUCTIONS
1
TABLE OF CONTENTS
SAFETY INSTRUCTIONS ...........................................1
SPECIFICATIONS .................................................2
SET UP DEHUMIDIFIER FOR INSTALLATION ........................3
Duct Collars....................................................3
Control Location................................................4
LOCATION CONSIDERATIONS .....................................4
DRAIN INSTALLATION ............................................5
Leveling .......................................................5
Condensate Pan, Condensate Pump and Float Switch ..............5
MODEL A77 – REMOTE OR EXTERNAL CONTROL AND WIRING......6
SYSTEM SET UP & CHECKOUT .....................................7
Installer Test Mode .............................................8
START UP AND SEQUENCE OF OPERATION ........................9
Using the Dehumidifier Control ..................................9
Using Model A77 Remote Control ................................9
TROUBLESHOOTING ............................................10
Table 2 – Diagnostic Codes .....................................10
Table 3 – Troubleshooting Guide .................................11
LIMITED WARRANTY .............................................11
SERVICE PARTS .................................................12
Alternate External Controls ......................................6
Wiring to Disable the Dehumidifier when
the Air Conditioning is Running..................................6
SPECIFICATIONS
TABLE 1 – SPECIFICATIONS
Unit Weight 113 lbs
Model A130
Capacity (AHAM DH-1-2008 80°F, 60% RH) 130 pints per day @ 310 CFM
Power (115 VAC, Single Phase, 60Hz) 8.3 Amps operating current
Dehumidifier Inlet Air Conditions Dehumidification: 50°F – 104°F, 40°F dew point minimum
Filter MERV 11
Airflow External Static Pressure ("w.c.) Airflow (CFM)
0.7" w.c. is maximum design external static pressure.
Ventilation: 40°F – 140°F, 0% RH – 99% RH (non-condensing)
0.0 310
0.2 270
0.4 225
0.6 175
2
SET UP DEHUMIDIFIER FOR INSTALLATION
IMPORTANT: Cut the strap securing the compressor shipping support bracket and remove the strap and shipping bracket. See FIGURE 1.
FIGURE 1 – REMOVE SHIPPING BRACKET
PACKAGING CONTENT
1. Dehumidifier
2. Inlet/Outlet Collars
3. Installation and Operating Insttructions
4. Parts Bag
a. #10 x 1/2 Screws (9)
b. Threaded Barbed Fitting for Drain Connections
c. Torx Bit
5. 10 Foot, 3/4" Drain Tube
DUCT COLLARS
If suspending the unit over the canopy but not ducting the unit, no duct collars are needed (see FIGURE 2). If ductwork will be installed to a suspended unit, attach the inlet and outlet duct collars as shown in FIGURE 3; the outlet cover does not need to be moved. If placing the unit on the floor, remove the outlet cover and install the outlet collar to the top of the unit, and relocate the cover to the end of the unit (see FIGURE 4).
REMOVE SCREWS (2) DISCARD SHIPPING BRACKET REINSTALL SCREWS (2)
CLIP OFF PLASTIC STRAP
90-2013
FIGURE 2 – HANGING INSTALL – NO DUCTING
OUTLET COVER
FIGURE 3 – HANGING INSTALL WITH DUCTING FIGURE 4 – FLOOR MOUNT INSTALL
OUTLET COVER OUTLET DUCT
INLET DUCT COLLAR
COLLAR WITH BACK DRAFT DAMPER
90-2014 90-2014
90-2016
MOVE OUTLET COVER AND INSTALL DUCT COLLAR TO TOP DISCHARGE LOCATION
3
CONTROL LOCATION
For floor mount installation, leave the control mounted to the top of the unit. For suspended installations, it will be easier to see if the control is relocated to the front of the unit.
To move the control:
1. Remove the front control panel cover.
2. Remove the filter access door and filter.
3. Detach the on-board control by removing the four
(4) screws around the control. NOTE: Use one hand to support the bottom of the on-board control when removing.
4. Keep the control in the unit and relocate to the front access hole.
FIGURE 5 – CONTROL LOCATION
CONTROL
CONTROL
PANEL COVER
CONTROL
PANEL COVER
CONTROL
5. Secure the control with the same four screws used to attach the control to the top of the unit.
6. Secure the control panel cover to the top of the unit.
LOCATION CONSIDERATIONS
• Allow sufficient clearance for filter removal and to
prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown. Allow sufficient space for service on this side of the unit.
• When suspending the unit, a condensate pan
with float switch is recommended to prevent any leaks that may occur due to unforeseen drain line obstructions.
FILTER ACCESS DOOR
90-2017
FIGURE 6 – FILTER ACCESS CLEARANCE
ELECTRICAL SERVICE ACCESS THIS SIDE
6" MINIMUM
CLEARANCE FOR PROPER AIR FLOW
4
6 FT. POWER CORD
TOP VIEW
FILTER
MINIMUM
20"
CLEARANCE FOR FILTER (EITHER SIDE)
90-2020
DRAIN INSTALLATION
The drain outlet on the dehumidifier can be hard piped using a 3/4" PVC Slip x 3/4" MNPT fitting and 3/4" nominal drain tubing or the provided 3/4" MNPT x 3/4" hose barb fitting and 3/4" clear PVC tubing can be used to drain the dehumidifier. Always maintain a constant downward slope from the dehumidifier to the drain and do not allow soft tubing to curl up which may result in air lock. NOTE: PTFE thread seal tape is recommended for the threaded connection and hand tighten only. If hard pipe is used, PVC primer and cement is recommended for the slip fit connection.
LEVELING
The feet can be adjusted to level the unit, and if required, to accommodate drain fittings and a secondary condensate pan. Leveling is required to ensure proper drainage from the dehumidifier. See
FIGURE 7.
FIGURE 7 – LEVEL THE UNIT
0.38" MIN
2.00" MAX
CONDENSATE PAN, CONDENSATE PUMP AND FLOAT SWITCH
A condensate pan is recommended when suspending the dehumidifier over the canopy. Adhere to local codes regarding draining of the condensate pan. If a condensate pump is needed, install it in the condensate pan as well.
Install a condensate overflow safety switch (i.e. float switch) in the condensate pan, remove the factory installed jumper wire between the Float Switch terminals on the control and wire the float switch to the dehumidifier as shown in FIGURE 8. Overflow safety switches on condensate pumps can be wired to the Float Switch terminals in a similar fashion.
3/4 " FNPT DRAIN
FIGURE 8 – FLOAT SWITCH WIRING
DH DH
FLOAT
Switch
NORMALLY CLOSED
FLOAT SWITCH
90-2021
90-1857
5
MODEL A77 – REMOTE OR EXTERNAL CONTROL AND WIRING
NOTE: Use 18-22 AWG wire for control wiring.
The internal dehumidifier control can be used to control humidity, or a remote Model A77 Control or other external control (see below) can be wired to the dehumidifier.
FIGURE 9 – MODEL A77 REMOTE CONTROL WIRING
Without an external control, the dehumidifier will turn on its blower for three minutes every 15, 30 or 45 minutes depending on how often the
+ - A B ODT
SensorRemote
Gh Rf Cf Gs YW
HVAC EQUIP.
unit is set to sample the air. The dehumidifier can also be set to sample the air continuously (see AIR SAMPLING on page 8). The blower is turned on to get a representative reading of the room relative humidity. A shorter sampling period reduces the duration of any humidity spikes
MODEL A77 CONTROL
that might occur when neither the air conditioning nor the dehumidifier are running. To reduce energy consumption the sampling time can be set to a longer period.
Installing an A77 or other control eliminates the need to run the dehumidifier blower for sampling as the control is constantly measuring the humidity close to the canopy. When the humidity level rises above the setting, the dehumidifier is turned on.
A
B C/­R/+ DH DH
90-1860
To install the Model A77 control:
1. Turn off power to the dehumidifier using the ON/OFF switch.
2. Run a 4-wire thermostat cable (use 18–22 AWG wire) from the Model A77 to the control of the dehumidifier.
3. Trim about 1/4" of insulation from the end of the wires on each end. Insert the wire into the terminals as shown in FIGURE 9 and tighten to secure.
4. Restore dehumidifier power. There is a delay of three minutes after restoring power before the dehumidifier will respond to the control.
5. Go to REMOTE CONTROL on page 7 to configure the dehumidifier control to respond to an A77 control.
The Model A77 will measure the relative humidity and turn the dehumidifier on and off to control the humidity level to the desired setting. The humidity setting can be adjusted from the control while the display allows easy access and monitoring of the humidity level in the space. It is recommended that the Model A77 be mounted at/near canopy height.
Press the ON button on the Model A77 to turn on the control. The UP/DOWN arrow buttons are used to set the desired humidity setting. At all other times, the Model A77 will display the measured humidity level. Reference the Model A77 Installation & Operating Instructions for set-up.
ALTERNATE EXTERNAL CONTROLS
A Model 8840 thermostat can be used to control the HVAC equipment, and for dehumidifier control in place of the Model A77. The Model 8840 thermostat has Wi-Fi capability so the conditions in the room can be monitored at any time from any location. Additionally, up to four remote sensors can be mounted near the canopy and connected to a single thermostat. The four humidity measurements can be averaged and the thermostat will turn on the dehumidifier based on the averaged value.
Reference the 8840 Installation Instructions and Owner’s Manual for wiring, set-up and operating details.
6
SYSTEM SET-UP & CHECKOUT
90-1854
90-1854 90-1854
90-1854
90-1854
90-1854
90-1854
90-1854
90-1854
Skip set up and proceed to INSTALLER TEST MODE on page 8 unless:
• A Model A77 or other external control is to be installed
• changing the air sampling rate
1. Make sure the wire access cover has been snapped back onto the on-board control.
2. Plug unit in and turn power switch to ON.
3. The on-board control screen should display OFF.
NOTE: If the display backlight is not on, the first button press (any
button) will only turn on the backlight. Press the button a second time to achieve function.
4. Hold the MODE button on the on-board control for 3 seconds to enter the Installer Set-up Menu.
5. Navigate through the following screens to set up the dehumidifier for the installed application.
Use the UP or DOWN buttons to select items and use MODE to
switch to the next set-up option. To exit installer set-up, all options must be scrolled through using the MODE button.
REMOTE CONTROL
If not installing an A77, leave DISABLED and press MODE to go to the next screen..
If installing an A77, use the UP or DOWN button to select ENABLED, then press MODE to go to the next screen.
VENTILATION
The ventilation feature can be used for air cycling if desired. The air cycling time can be set from 0 to 60 minutes. The dehumidifier will turn on the dehumidifier fan to cycle air for the set time, every hour.
If not using the dehumidifier to cycle air, leave DISABLED and press MODE to go to the next screen.
6. After the installer set up options have been completed, DONE will blink for 3 seconds and the control will return to the OFF screen.
If using the dehumidifier for air cycling, use the UP or DOWN button to select ENABLED, then press MODE to go to the next screen.
Press MODE at the VENT TIMED screen to set the air cycling time.
Press the UP or DOWN button to adjust the air cycling time per hour from 0 to 60 minutes. After selecting time, press MODE to go to the next screen.
7
EXTERNAL CONTROL
90-1854
90-1854
90-1854
90-1854
90-1854
90-1854
90-1854
90-1854
If using the dehumidifier on-board control, leave DISABLED and press MODE to go to the next screen.
If using a Model 8800 series thermostat or alternate control as an external control, use the UP or DOWN button to select ENABLED, then press MODE to go to the next screen.
AIR SAMPLING
Use the UP or DOWN button to adjust how frequently the dehumidifier samples the air to determine whether or not to dehumidify. Fewer minutes means
90-1854
the dehumidifier will sample more frequently to minimize humidity swings, but increases cost to operate due to more frequent fan operation. Press MODE when done to move to the next screen.
RH OFFSET
An offset can be applied to the on-board humidity reading to avoid discrepancies with other humidity measuring devices in the home. Use the UP or DOWN button to select an offset from -5% to 5%. Press MODE to exit the installer set-up screens.
INSTALLER TEST MODE
If everything is properly wired, the dehumidifier and all of the wired components will turn on and off during Installer Test Mode to demonstrate that all are properly operating. Installer Test Mode lasts for four (4) minutes. If the ON/OFF button is pressed during test mode, the dehumidifier will exit Installer Test Mode and return to the OFF screen.
DEHUMIDIFICATION ONLY
If the dehumidifier is not already OFF, press the ON/ OFF button to turn it off.
Press and hold the ON/ OFF button and MODE buttons for 3 seconds. The measured humidity, AIR SAMPLING and TEST will show on the display.
After three (3) minutes the dehumidifier compressor will turn on and DEHUMIDIFYING will replace AIR SAMPLING on the control screen.
After one minute of compressor operation, all outputs will turn off and DONE will blink for 3 seconds and then return to the OFF screen.
8
START UP AND SEQUENCE OF OPERATION
USING THE DEHUMIDIFIER CONTROL
1. Press the ON/OFF button to turn the dehumidifier control ON. The display will show the current setting, and the dehumidifier blower will turn on
to start sampling the air.
The setting will be replaced by the measured humidity and “AIR SAMPLING” will show on the display.
2. Use the UP or DOWN button to adjust the humidity setting as desired.
3. After three (3) minutes of sampling, the measured humidity will be compared to the setting:
a. If the humidity is above the setting, the dehumidifier compressor turns on and “AIR SAMPLING” will be replaced by “DEHUMIDIFYING”. The
compressor remains on until the measured humidity falls 3% RH below the setting.
b. If the measured humidity is below the setting, the blowers turn off and the display returns to showing the RH setting.
4. The dehumidifier will sample again after the number of minutes selected during the Air Sampling portion of the System Set Up (see page 8), or
any time the humidity setting is lowered.
USING THE MODEL A77 REMOTE CONTROL
1. Press the ON/OFF button to turn the dehumidifier control ON. “REMOTE” will show on the display to indicate that an external control is wired to
the dehumidifier.
2. At the Model A77, press the ON button; the Model A77 will display the measured RH.
3. Use the UP or DOWN button on the Model A77 to adjust the humidity setting as desired.
4. If the RH measured by the Model A77 rises above the setting, the dehumidifier will turn on. “DEHUMIDIFYING” will appear on the dehumidifier
control display to show that the Model A77 is calling for dehumidification. The dehumidifier will turn off when the RH measured by the Model A77 drops 3% RH below the setting.
9
TROUBLESHOOTING
Technical Support is available Monday through Friday, 7:00 a.m. to 5:00 p.m. CST, at (800) 972-3710. Use the guides on the following pages to identify and correct system faults. Contact Technical Support before replacing the unit or any components and for additional troubleshooting.
TABLE 2 – DIAGNOSTIC CODES
Diagnostic
Code Failure Mode Action Reset
E1 Internal Humidity or
Temperature Sensor Open or Shorted
E2 High Refrigeration
Pressure
E3 Model A77
Remote Control Communication Loss
E4 Insufficient Capacity 1. Check the frost sensor connection at the power board. Terminal should be fully seated on the power
1. Check the connection between the sensor board and control board.
2. If connection okay, replace sensor board, Part No. 5460.
1. Verify that the fan works, the backflow damper swings freely and there is no blocked or restricted ductwork.
2. If the fault persists, call Technical Support.
1. Check connections between Model A77 and dehumidifier control board. Terminals should be fully
inserted and secured in the control board and Model A77 control terminals.
2. If connections are correct and secure, turn off the dehumidifier and remove the Model A77. Use a short section of 4-wire cable to reconnect the Model A77 to the control board. Turn the dehumidifier back on and increase the dryness level setting on the Model A77. If the dehumidifier turns on, the problem is with the wiring between the dehumidifier and control.
3. If the dehumidifier does not turn on, call Technical Support.
board pins.
2. Remove the side access panel and verify that the sensor is secured to the suction line.
3. If the sensor is connected and secured to the refrigeration line proceed to the next step.
4. Reset the fault by cycling power to the dehumidifier.
5. Turn the humidity setting down (below room/home humidity level) to make a dehumidification call.
6. Allow the fan and compressor to run for approximately 10-15 minutes and then enter diagnostic
test mode by simultaneously pressing the UP ARROW and MODE buttons for 3 seconds. The LCD will display the temperature measured by the internal sensor while also displaying AIR SAMPLING and ON, the humidity measured by the internal sensor while also displaying %RH and ON, and the frost sensor temperature while also displaying ON. Scroll through these values and by using the UP/ DOWN arrow buttons.
7. Record values and call Technical Support.
DIAGNOSTIC CODES
When an error occurs, the Diagnostic Code along with SERVICE REQUIRED will be displayed on the control screen.
90-1854
Cycle Power
Cycle Power
Self-Correcting
Cycle Power
E5 High Temperature
Thermistor Failure
E6 Low Temperature
Thermistor Failure
E7 Float Switch Open 1. Empty the condensate pan.
E8 Inlet Air Temperature
Out of 50°F – 104°F range or dew point below 40°F
10
1. Check the high temperature sensor connection at the power board. Terminal should be fully seated on the power board pins.
2. Remove the side access panel and verify the sensor is not damaged and connected to the refrigeration line coming from the compressor.
3. If the sensor is connected and secured to the refrigeration line, it may need to be replaced with Part No. 5456 – contact Technical Support to confirm.
1. Check the low temperature sensor connection at the power board.
2. Remove the side access panel and verify the sensor is not damaged and connected to the suction line.
3. If the sensor is connected and secured to the refrigeration line, it may need to be replaced with Part
No. 5455 – contact Technical Support to confirm.
2. Check the float switch connection at the control board.
3. If not using a float switch, verify jumper is between float switch terminals on dehumidifier control board.
4. If the problem persists, replace the float switch.
1. Verify all ductwork is properly sealed.
2. If no signs of leak points, contact Technical Support.
Cycle Power
Cycle Power
Self-Correcting
Self-Correcting
TABLE 3 – TROUBLESHOOTING GUIDE
Symptom Possible Reason Troubleshooting Procedure
Dehumidifier does not turn on/run.
Dehumidifier blower is running but with little or no airflow.
Dehumidifier blower is running but compressor is not.
Dehumidifier is not draining properly.
Dehumidifier is producing hot air.
No power to unit. • Check that the dehumidifier is plugged in.
• Check that the power switch is turned ON.
• Check that the control is turned ON.
• Check that the circuit breaker has not tripped.
Pressure drop across dehumidifier is too high.
• Check dehumidifier air filter and replace if necessary.
• Check for blocked duct work and clear.
Float switch open. • If float switch installed, check connections at control board and empty condensate pan.
• If no float switch installed check that the jumper is installed at the float switch terminals on the control board.
Coil frosting – defrost. • Lack of or reduced airflow. Check dehumidifier air filter and replace if necessary.
• Check for blocked duct work.
• Inlet air conditions below 60°F. Increase the humidity setting.
Inlet air temperature is
• Verify all ductwork is properly sealed.
outside of the 50°F – 104°F range or the dew point is below 40°F and there is a demand for dehumidification.
Drain line blocked or unit not level.
• Verify that the unit is level.
• Check the drain line blockages and for a continuous downward slope.
Normal function. • Air is reheated across the condenser coil, resulting in a temperature rise between inlet and outlet, this is
normal.
LIMITED WARRANTY
Your Research Products Corporation Anden™ Dehumidifier is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the dehumidifier.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
WARRANTY REGISTRATION
Visit us online at anden.com to register your Anden product. If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P.O. Box 1467, Madison, WI 53701.
Your warranty registration information will not be sold or shared outside of this company.
11
SERVICE PARTS
17
4
8
3
9
19
1
6
10
12
13
2
16
14
7
15
5
No. Part Description Part No.
1 Filter, 14" x 19" x 1" 5701
2 Internal Control Board, Deh 5444
3 User Interface Assembly, Deh 5738
4 Hole Cover, UI Ctrl, Deh 5447
5 Door, Filter Access, Deh 5571
6 Outlet Duct Panel, Deh 5449
7 Backflow Damper, 10", Deh 5450
8 Inlet Duct Panel, Deh 5451
9 Cover, Outlet, Deh 5452
10 Fan, 130pt Deh, with 10MFD Capacitor 5572
anden.com
P.O. Box 1467 Madison, WI 53701-1467
800.972.3710 F: 608.257.4357 Printed in USA ©2019 Anden –A Quality brand from Research Products Corporation 10013580 B2208340B 2.19
11
18
No. Part Description Part No.
11 Wire Harness, Power, Deh 5454
12 Sensor, Low Temperature, Deh 5455
13 Sensor, High Temperature, Deh 5456
14 Leveling Foot, Deh 5457
15 Capacitor, 50MFD, 370VAC 5594
16 Capacitor, 10MFD, 250VAC 5573
17 RH Sensor, Deh 5460
18 Drain Tube + Fitting 5665
19 Compressor Overload Switch 5574
90-2031
12