The IVS3000R Series is a compact 3000VA DC/AC pure sinewave
inverter that uses established design techniques to ensure high
reliability.
Suitable for a wide range of applications, the IVS3000 features full
electronic protection, high efficiency and low output noise.
The built-in fan provides sufficient airflow for operation without
de-rating up to 50oC ambient temperature. Extended operating
temperature (-40 to +65oC) is available.
DC/AC Pure Sine
Inverters
Model
IVS3000R
Benefits
◆ Ultra-Quiet
◆ Power sensitive electronics without interference
◆ Rugged & Reliable
◆ Ensure years of safe and trouble free operation
Design Features
◆ Input is filtered to EN 55022 Class B
◆ Very low 60Hz input ripple current
◆ Modular design, light weight
◆ Sinusoidal wave shape
◆ Multiple input and output voltages available
◆ 2500VA of output power
◆ Full electronic protection
◆ Field-proven design topology
Applications
◆ Marine / Automotive / RV
◆ Electric Utilities and Substations
◆ Telecom Power Plants
◆ Manufacturing Locations
◆ Steel Mills
◆ Military Applications (COTS)
◆ Industrial Controls
◆ OEM Applications
◆ Solar / Alternative Power Systems
◆ Fuel Cells

DC/AC Pure Sinewave Inverters
IVS3000R Series Pure Sinewave Inverters
Input Voltage
Input Protection ermal fuse, Inrush current limiting, Reverse polarity protection
Isolation 1400VDC input to output, input to chassis / 500VDC output to chassis
Output Voltage
Wav e F orm Sinusoidal
Total Harmonic Distortion Less than 5% at full load
Eciency Min 82% at full load
Line Regulation Maximum 0.5%
Load Regulation Maximum ± 6% from 10% load to full load ( ± 1% option available)
Output Noise High frequency ripple is better than 500mV rms (20MHz BW)
Output Protection
RFI Suppression Meets requirements of EN55022, Class A conducted emissions as a minimum
24, 32, 48, 125, and 250VDC are standard (Operating range +/-15% of nominal)
Other inputs available - please consult factory
115V rms / 26A rms or 220VAC / 13.6A (50 or 60Hz standard)
Consult factory for other voltages and frequencies
Current limiting with short circuit protection, thermal shutdown with automatic recovery in case of continuous
overload or insucient airow
Output Over-voltage Protection By internal supply voltage limiting at 140VAC on output
Output Over-load Protection: Hiccup at 6,000W
Load Crest Factor Maximum 2.5 at 90% load
Operating Temperature Range 0o C to +50o C
Humidity 5 - 95% non-condensing
Temperature Dri 0.05% per o C over operating temperature range
Dimensions
Connections
Weight 55 lb (31.8 Kg)
Safety Compliance to C22.2 No. 107.1 - 01 and UL 458
Note: Specifications are subject to change without notice.
Warranty: Twenty four months subject to application within good engineering practice
Enhancements to these general specifications can be accommodated upon request
Designed to meet common approval requirements. Specifications Subject to Change Without Notice
Designed and Manufactured in Canada
4U x 19” rack-mount enclosure. Depth is 17” maximum
Depending on input
Input: Compression-type terminal
Output: Standard AC receptacle