Analytic Systems IVS2500R Data Sheet

Page 1
Description
The IVS2500R Series is a compact 2500VA 19” Rackmount DC/AC pure sinewave inverter that uses established design techniques to ensure high reliability.
Suitable for a wide range of applications, the IVS2500R features full electronic protection, high efficiency and low output noise.
The built-in fan provides sufficient airflow for operation without de-rating up to 50oC ambient temperature. Extended operating temperature (-40 to +65oC) is available.
The inverter can be loaded with a fluorescent lamp load up to the full-specified output power.
DC/AC Pure Sine Inverters
Model IVS2500R
Benefits
Ultra-Quiet
Power sensitive electronics without interference
Rugged & Reliable
Ensure years of safe and trouble free operation
Input is filtered to EN 55022 Class B
Very low 60Hz input ripple current
Modular design, light weight
Sinusoidal wave shape
Multiple input and output voltages available
2500VA of output power
Full electronic protection
Field-proven design topology
Applications
Marine / Automotive / RV
Electric Utilities and Substations
Telecom Power Plants
Manufacturing Locations
Steel Mills
Military Applications (COTS)
Industrial Controls
OEM Applications
Solar / Alternative Power Systems
Fuel Cells
Page 2
DC/AC Pure Sinewave Inverters
IVS2500R Series19” Rackmount Pure Sinewave Inverters
Input Voltage
Input Protection ermal fuse, Inrush current limiting, Reverse polarity protection
Input Isolation
Output Voltage
Wav e F orm Sinusoidal
Total Harmonic Distortion Better than 5% at full load
Eciency Min 78% at full load
Line Regulation Maximum 0.5%
Load Regulation Maximum ± 6% from 10% load to full load
Output Protection
EMI / RFI Suppression Meets EN 55022 Class B
Load Crest Factor Maximum 3.0 at 90% load
24V, 32V, 48V, 125V, 270VDC +/-20% are standard Other inputs available, please consult factory
Input to chassis 500VDC for <60V input – 1500VDC for >60V input Input to output 2250VDC – Output to chassis 2250VDC
115VAC/60Hz /21.7A continuous or 220VAC / 10.9A (50 or 60Hz standard) with grounded neutral Isolated oating output optional (Consult factory for other voltages and frequencies)
Current limiting with short circuit protection, thermal shutdown with automatic recovery in case of continuous overload or insucient airow
Operating Temperature Range 0o C to +50o C
Humidity 5 - 95% non-condensing
Temperature Dri 0.05% per o C over operating temperature range
Dimensions 6U” X 19” x 15” enclosed case (H x L x W)
Connections
Weight 30 lb (13.6 Kg)
Options
Safety
Note: Specifications are subject to change without notice.
Warranty: Twenty four months subject to application within good engineering practice Enhancements to these general specifications can be accommodated upon request Designed to meet common approval requirements. Specifications Subject to Change Without Notice Designed and Manufactured in Canada
Input: Compression-type terminal block Output: Standard AC receptacle
Output Fail Alarm (Form C) Remote Inhibit: by connecting DC voltage (as specied) to the inhibit terminal
Compliance to IEC950, CSA C22.2 No. 950 and UL 1950 Please contact factory for approval status for the requested input/output conguration