Analytic Systems IVS1000 Data Sheet

Description
The IVS1000 Series is a highly compact 1000VA DC/AC pure sinewave inverter that uses established design techniques to en­sure high reliability.
DC/AC Pure Sine Inverters
Model IVS1000
Benefits
Ultra-Quiet
Power sensitive electronics without interference
Rugged & Reliable
Ensure years of safe and trouble free operation
Input is filtered to EN 55022 Class A
Very low 60Hz input ripple current
Compact size, light weight
Sinusoidal wave shape
Multiple input and output voltages available
1000VA of output power
Full electronic protection
Field-proven design topology
Also available as a frequency converter with 115VAC or 230VAC input
Suitable for a wide range of applications, the IVS1000 features full electronic protection, high efficiency and low output noise. The built-in fan provides sufficient airflow for operation without de-rating up to 50oC ambient temperature. Extended operating temperature (-40 to +65oC) is available.
The inverter can be loaded with a fluorescent lamp load up to the full-specified output power.
Applications
Marine / Automotive / RV
Electric Utilities and Substations
Telecom Power Plants
Manufacturing Locations
Steel Mills
Military Applications (COTS)
Industrial Controls
OEM Applications
Solar / Alternative Power Systems
Fuel Cells
DC/AC Pure Sinewave Inverters
IVS1000
Input Voltage
Input Protection
Isolation
Output Voltage
Wav e F orm Sinusoidal
Total Harmonic Distortion Less than 5% at full load
Eciency Min 76% at full load
Line Regulation Maximum 0.5%
Load Regulation
Output Protection
Output Overvoltage Protection 140/280 V by internal supply voltage limiting
EMI Meets EN 55022 Class A as a minimum
24V, 36V, 48V, 125V, 250VDC +/-15% are standard Other inputs available, please consult factory
ermal fuse, Inrush current limiting, Reverse polarity protection, Varistors, Lower voltage than specied input min. will not damage unit
Input to chassis 500VDC for < 60V input, 1500VDC for > 60V input Input to output 2250VDC, Output to chassis 2250VDC
115VAC/60Hz or 400Hz @8.7A 230VAC/50Hz @ 4.35A continuous with grounded neutral. Isolated oating output optional (Consult factory for other voltages and frequencies)
Maximum ± 6% from 10% load to full load ± 2% load regulation option available
Current limiting with short circuit protection, thermal shutdown with automatic recovery in case of continuous overload or insucient airow
Load Crest Factor Maximum 2.5 at 90% load
Output Noise High frequency ripple is better than 500m Vrms (20MHzBW)
Operating Temperature Range 0o C to +50o C
Humidity 5 - 95% non-condensing
Temperature Dri 0.05% per o C over operating temperature range
Cooling Build-in fan drawing air into the unit
Environmental Protection
Dimensions 7.5” x 5.3” x 15.5” (W x H x L) including terminal block and anges
Connections
Weight 13.0 lb (5.9 kg)
Safety Compliance to C22.2 No. 107.1 - 01 and UL 458 and EN60950
Options
Note: Specifications are subject to change without notice.
Designed to meet common approval requirements. Specifications Subject to Change Without Notice
Basic ruggedizing Full ruggedizing and conformal coating as option
Input: Compression-type terminal Output: Standard AC receptacle
Output Fail Alarm (Form C) Remote Inhibit: By closing external contacts on the inhibit terminals
Warranty: Twenty four months subject to application within good engineering practice
Enhancements to these general specifications can be accommodated upon request
Designed and Manufactured in Canada