Analytic Systems FTP1500R Data Sheet

Page 1
AC/AC Frequency Converters
FTP1500R
Input Voltage 115VAC, 60Hz - 400Hz
230VAC, 50Hz single phase (Consult factory for other inputs)
Input Protection ermal fuse, Inrush current limiting
Isolation 2250 VDC input to chassis / 2250 VDC input to output / 2250 VDC output to chassis
Output Voltages 208rms/ 3-phase continuous or 380Vrms/3-phase continuous or 415Vrms/3-phase continuous at 50, 60, or
Wave Form Sinusoidal
Total Harmonic Distortion Less than 5% at full load
Eciency Min 78% at full load
Line Regulation Maximum 0.5%
Load Regulation Maximum ± 6% from 10% load to full load
Output Protection Current limiting with short circuit protection, thermal shutdown with
EMI EN 55022 Class B (typical)
Load Crest Factor Maximum 3.0 at 90% load
Frequency Stability ± 0.1%
Operating Temperature Range 0o C to +50o C (Extended range available, Consult factory)
Humidity 5 - 95% non-condensing
Temperature Dri 0.05% per o C over operating temperature range
Dimensions 4U x 19” x 15” Enclosed Case
Connections Input/output: terminal block
Weight 40 pounds (18.2kg)
Safety Designed to meet C22.2 No. 107.1 - 01, UL 458 and EN60950 Please contact factory for approval status for the
400Hz.
e centre point (neutral) is oating - it can be grounded
(Consult factory for other voltages and frequencies)
automatic recovery in case of continuous overload or insucient airow
requested input/output conguration
Warranty: Twenty Four months subject to application within good engineering practice . Enhancements to these general specifications can be accommodated upon request Designed to meet common approval requirements. Specifications Subject to Change Without Notice. Designed and Manufactured in Canada
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 1.800.668.3884 (US/CANADA)
www.analyticsystems.com