Benefits
Ultra-Quiet
Power sensitive electronics without interference
Rugged & Reliable
Ensure years of safe and trouble free operation
Input is filtered to EN 55022 Class B
Very low 60Hz input ripple current
Modular design, light weight
Sinusoidal wave shape
Multiple input and output voltages available
5000VA of output power
Full electronic protection
Field-proven design topology
Description
The FCA5000R Series is a compact AC/AC frequency converter that uses established design techniques to ensure high reliability. Suitable for a wide range of applications, the FCA5000R features full electronic protection, high efficiency and low output noise.
The built-in fan provides sufficient airflow for operation without de-rating up to 50oC ambient temperature. Extended operating temperature (-40 to +65oC) is available.
The converter can be loaded with a fluorescent lamp load up to the full specified output power.
Applications
Marine / Automotive / RV
Electric Utilities and Substations
Telecom Power Plants
Manufacturing Locations
Steel Mills
Military Applications (COTS)
Industrial Controls
OEM Applications
Solar / Alternative Power Systems
Fuel Cells
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 1.800.668.3884 (US/CANADA)
www.analyticsystems.com
Page 2
AC/AC Frequency Converters
FCA5000R
Input Voltage
Input Protection ermal fuse, Inrush current limiting, Reverse polarity protection
Isolation 2250 VDC input to chassis / 2250 VDC input to output / 2250 VDC output to chassis
Output Voltage
Wav e F orm Sinusoidal
Total Harmonic Distortion Less than 5% at full load
Eciency Min 78% at full load
Line Regulation Maximum 0.5%
Load Regulation Maximum ± 6% from 10% load to full load
Output Protection
EMI Meets EN 55022 Class B
Load Crest Factor Maximum 3.0 at 90% load
Operating Temperature Range
115 or 230VAC, 48…410Hz +/-20% are standard Other inputs available, please consult factory
115VAC / 60Hz / 43.4A or 115VAC / 400Hz / 43.4A or 230VAC / 50Hz / 21.7A continuous with grounded neutral Isolated oating output optional (Consult factory for other voltages and frequencies)
Current limiting with short circuit protection, thermal shutdown with automatic recovery in case of continuous overload or insucient airow
0o C to +50o C Extended range available (Consult factory)
Humidity 5 - 95% non-condensing
Temperature Dri 0.05% per o C over operating temperature range
Dimensions
Connections
Weight 60 pounds (31.8 kg)
Safety
Warranty: Twelve months subject to application within good engineering practice Enhancements to these general specifications can be accommodated upon request Designed to meet common approval requirements. Specifications Subject to Change Without Notice Designed and Manufactured in Canada
6U x 19” rack-mount enclosure Depth: 18” maximum
Input: Compression-type terminal Output: Standard AC receptacle
Compliance to IEC950, CSA C22.2 No. 950 and UL 1950 Please contact factory for approval status for the requested input/output conguration
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 1.800.668.3884 (US/CANADA)