Power sensitive electronics
Marine & other Rugged Environments
DC Battery Charger s
BCD315 Isolated Battery Charger
• Ultra-Quiet
•
without interference
• Rugged & Reliable
• Ensure years of s
trouble free operation
• Fast & Accurate Charging
•
• Telecommunications Equipment
• Electric Utilities and Substations
• Manufacturing Plants
• Steel Mills
• Military Applic a t i
• Industrial Controls
The BCD315 battery charger provides up to 300 watts to charge a 12 or
24 or 48 Volt battery system (1, 2 or 3 Banks) from a 24V, 48V or
72VDC source. The batteries must share a common ground but the
source can be on a different positive or negative ground.
The all-new Current Mode switching design offers increased power and
reliability in a compact package. The low ripple charging profile and
standard equalize cycle greatly increases the lifetime of expensive
battery systems. Extra input and output filtering reduce EMI to
extremely low levels. Reliability features include an input fuse, thermal
shutdown, current limiting, reverse battery hookup protection and output
short circuit shutdown with automatic recovery.
Optional features include a Digital Volt/Ammeter, a Remote Control
Panel, and/or a second Battery Temperature Sensor. We are confident
that you will get many years of reliable service from this DC Battery
• Fully Isolated Design
• Adjustable output voltage for
charging standard or deep cycle
lead-acid, VRLA or Gel cell type
battery
• Transient Voltage Suppressor
• Extremely rugged and well suited
for marine and other demanding
environments
• User selectable 2 or 3
stage charging profile
• Audible & visual in d ic at or s
for output overload, low
input voltage, low output
voltage & over-temperature
• Over-temperature
shutdown
• Short circuit protection
• OEM Applications
• Solar / Alternative Power Systems
• Fuel Cells
•
• High tolerance for shock and
vibration
• Ultra-quiet low EMI operation
• Can be left permanently
connected
• Spark free connection
• Output over-voltage
crowbar
• Inrush Current Limiting with
solid state bypass
• Dry contact output fail relay
• 3 year parts and labour
warranty

-25° to +40°C @ maximum output
0 - 95°C Relative Humidity
3.0 Amps 1.5 Amps 0.75 Amps
16.0 ± 0.5V 32.0 ± 1.0V 63.9 ± 2.0V
-30 mV/°C -60 mV/°C -120 mV/°C
Continuous 100% for 24 hours per day
1 inch (2.5 cm) all around
Black Anodize / Powder Epoxy Coat
Four contact output terminals
Shown without Digital Meter
Shown with Digital Meter
Noise on Input
18.7 9.4 5.7
< 25 mV
13.6 ± 0.05 27.2 ± 0.05 54.4 ± 0.05
80 -120 40 - 60 20 - 30
2 or 3 (user selectable)
Operating Temp.
Range
Humidity
Isolation
Derate Linearly 2.5% per °C from 40°C
(Optional -40°C extra wide temp. operation avail.)
(non-condensing) with optional conformal coating
Input-Case & Input-Output 1500VDC (500VDC@24V I/P)
Output-Case 500VDC
9.6 in / 24.4 cm
Built to meet UL458 & CSA 22.2.107.1