Analytic Systems BCD1000 Data Sheet

Page 1
(Shown with Optional Digital Meter)
Ensure years of safe and
Marine & other Rugged Environments
ns (COTS)
Charge any DC/DC System
warranty
DC Battery Charger s
BCD1000 Isolated Battery Charger
• Ultra-Quiet
• Power sensitive electronics
without interference
• Rugged & Reliable
•
trouble free operation
• Fast & Accurate Charging
•
• Electric Utilities and Substations
• Manufacturing Plants
• Steel Mills
• Military Applic a t io
• Industrial Controls
• OEM Applications
• Solar / Alternative Power Systems
• Fuel Cells
•
The model BCD1000 Battery Charger charges either 12V, 24V or 48V batteries from a 110, 220 or 300VDC power source. Other battery voltages up to 72 volts are also available by special order.
The all-new Current Mode switching design offers increased power and reliability in a compact package. Extra input and output filtering reduce EMI to extremely low levels. Reliability features include an input fuse, thermal shutdown, current limiting, reverse battery hookup protection, output short circuit shutdown with automatic recovery and an equalize charge mode. The output voltage is easily adjusted 1.0 volts above or below the standard output voltage to accommodate special charging requirements.
Optional features include a Digital Volt/Ammeter, Remote Control Panel, and/or 19” Rackmounting. We are confident that you will get ma ny years of reliable service from this DC Battery Charger.
• Fully Isolated Design
• Adjustable output voltage for
charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
• Transient Voltage Suppressor
• Extremely rugged and well suited
for marine and other demanding environments
• High tolerance for shock and vibration
• Ultra-quiet low EMI operation
• Can be left permanently
connected
• User selectable 2 or 3 stage charging profile
• Audible & visual in d ic at or s for output overload, low input voltage, low output voltage & over-temperature
• Over-temperature shutdown
• Short circuit protection
• Output over-voltage
crowbar
• Inrush Current Limiting with solid state bypass
• Dry contact output fail relay
• Spark free connection
• 3 year parts and labour
Page 2
-25° to +40°C @ maximum output 0 - 95°C Relative Humidity
Audible Noise
NONE Ødb @ 3 ft (34.5 dB when fan operating)
Typical Service Life
> 10 yrs. (87,600 hrs)
Nominal (ip)
110 250 300
Actual (Vdc)
100-140 230-280 280-360
Input Amps (max)
14.8 6.5 5.3
Input Fuse (MDA)
15 7 6
Output Nominal (op)
12 24 48
Output Volts (DC)
13.6 ± 0.05 27.2 ± 0.05 54.4 ± 0.05
Absorption Voltage (Vdc)
14.4 28.8 57.6
Charging Amps
60 40 20
Absorption to Float
9 .0 Amps 6 .0 Amps 3.0 Amps
Output Adjustment (Vdc)
Output Fuses (ATC)
40 x 2 40 x 2 25 x 2
Battery Banks
1 or 2 (3 Bank Option Available)
Battery Size (Amp Hrs.)
Output Crowbar
16.0 ± 0.5V 32.0 ± 1.0V 63.9 ± 2.0V
Output Ripple & Noise
< 50 mV
Regulation (Line & Load)
Temperature Comp.
-30 mV/°C -60 mV/°C -120 mV/°C
Duty Cycle
Continuous 100% for 24 hours per day
Efficiency
> 80% @ Maximum Output
Stages
Length
Width
9.9 in / 25.1 cm
Height
5.5 in / 14.0 cm
Clearance
1 inch (2.5 cm) all around
Material
Marine Grade Aluminium
Finish
Black Anodize / Powder Epoxy Coat
Fastenings
All 18-8 Stainless Steel
Weight
Connections
Four contact output terminals
Warranty
3 years
Safety
Available From:
Noise on Input
< 50 mV
± 1.0V
240-360 160-240 80-120
< +/- 0.5%
2 or 3 (user selectable)
Operating Temp. Range
Humidity
Isolation
Derate Linearly 2.5% per °C from 40°C (Optional -40°C extra wide-temp. operation avail.)
(non-condensing) with optional conformal coating
Input-Case & Input-Output 1500VDC Output-Case 500VDC (1500V @ 48V Output)
14.5 in / 36.8 cm
12.0 lb / 5.5 kg
Built to meet cETLus Standards
Loading...