Analytical Industries Inc (AII) AII-3000-A, AII-3000-AHC, AII-3000-M, AII-3000-MHC Specifications

Handheld Meters for O2 and CO
AII-3000 and Palm Series
These ergonomic handheld gas analyzers are a convenient way to check oxygen levels in welding applications or for the safety checks of breathing air for diving.
Highlights
0-100% O2 measurement range
Long sensor life up to 60 months (AII-3000)
Battery life up to 18 months
continuous use (Palm O2)
Integrated or remote sensors
Fast response time of T90 in <10 seconds
Applications
Weld purge gas quality
Personnel safety protection
Checking concentrations of oxygen in scuba
tanks or nitrox mixtures
Checking for carbon monoxide in scuba tanks
AII-3000
O
2
With four format options, these handhelds give user the flexibility to match the instrument to their needs with four combinations of alarms, no alarms, internal and external sensors. 2 AA batteries give up to 50 days of use.
AII-3000-A – External sensor, no alarm AII-3000-AHC – Internal sensor, no alarm AII-3000-M – External sensor, alarm AII-3000-MHC – Internal sensor, alarm
Accessories
Accessories for sampling and mounting are also available – see order code sheet for details.
Palm O2 and Palm CO
O
2
CO
With only two buttons, and one-touch calibration, they are very simple to use. This is the ideal cost-effective choice to check for O2 or CO in your scuba tanks. Palm O2 is available with internal or external sensor and offers excellent battery life of up to 18 months of use.
Accessories
Dome Adapter (A-3388), 1/8” tube (A-3676) or BC adapter (A-3671)
www.aii1.com
Technical Specifications
AII-3000 Palm O2 Palm CO Analyzer
Measurement range 0-100% oxygen 0-25 ppm CO
Accuracy < ±2% of FS range under constant conditions
Response time T90 < 10 seconds T90 < 30 seconds Sensitivity (LDL) 0.50% 0.5 ppm CO Linearity ±1% under constant conditions
Sensor model
Sensor life at 25°C (77°F) and 1 atmosphere
Calibration interval Prior to use and after 8 hours operation
Inlet pressure Ambient or 0.34-2 barg (5-30 psig) for flow through connector
Flow rate (constant) 0.2-10 Nl/min (0.4-20 SCFH)
Gas connections
Display
AII-11-60 (remote sensor)
AII-11-60-HC
60 months in air 32 months in air 24 months in air
1x16 mm thread
1/4” tube for remote sensors
See accessories for additional connectors
3½ digit backlit LCD 7 x 3.5cm
(2.75 x 1.375”); resolution 0.1
AII-11-75-PO2
AII-11-75-PO2-D (for diving)
3 digit LCD 2.8 x 1.6cm (1.1 x
0.625”); resolution 0.1
< ± 2 ppm under constant
conditions
OSV-22-AF
Certified span gas mixture of
CO concentrations between 10-
20 ppm with balance air.
800 1200 mbara (11.6-17.4
psig)
Supplied with Dome adapter
(A-3388) with optional BC
adapter (A-3671)
2 digit LCD 2.8 x 1.6cm (1.1 x
0.625”); resolution 1 ppm CO
Dimensions
Weight 280g (10oz) 196g (7oz) Compensation Temperature compensated NA Alarms User adjustable HI and LO alarms (AII-3000 M and MHC only) Storage temperature -20°C to +60°C (-4°F to 140°F) on intermittent basis 3°C to 35°C (37.4°F to 95°F) Operating temperature 5 to 45°C (41°F to 113°F) 0°C to 50°C (32°F to 122°F) Power 2 AA alkaline batteries Battery Life Up to 1200 hrs Up to 13,000 hrs Up to 450 hrs of continual use Humidity Non-condensing 0-95% RH Warm up time None 60 Seconds Approvals ISO 9001:2000, MDD 93/42/Annex II, ISO 13485:2003 None
9.1 x 14.9 x4 cm (3.6 x 5.9 x
1.6”)
6.9 x 10.4 x 3.4cm (2.72” x 4.1” x 1.35”)
Analytical Industries Inc. 2855 Metropolitan Place, Pomona, CA 91767 USA Tel: 909-392-6900, Fax: 909-392-3665, www.aii1.com, e-mail: info@aii1.com
Please note: Analytical Industries Inc. adopts a continuous development program which sometimes necessitates specification changes without notice.
www.aii1.com
Please contact us for the latest version. Issue No: Handheld O
Meters_partnumber_V2_UK_1018
2