Analogic Technologies AHK432ILY-2-B1, AHK432ILY-2-A1, AHK432ILY-1-B1, AHK432ILY-1-A1, AHK432IGY-2-T1 Datasheet

...
General Description
AHK432
Adjustable Low Voltage Shunt Regulator
Features
PowerManager
SmartSwitch
The AHK432 is a low voltage adjustable shunt refer­ence with thermal stability guaranteed over the full industrial temperature range. This 3-terminal regula­tor has an output voltage range that extends from V
(1.24V) to 20V, giving designers outstanding
flexibility in the development of power supplies and instrumentation. With a low operating current of 60µA, the AHK432 is well suited for battery-powered portable electronic applications. It also has a sharp turn-on characteristic and a dynamic resistance of only 50mW making it an excellent replacement for zener diodes in low tempco designs.
The AHK432 is available in the surface-mount 3 or 5 pin SOT-23, as well as the through hole TO-92. Three voltage tolerance options are offered in each package: ±0.5%, ±1%, and ±2%.
Wide output voltage range (1.24 to 20V)
Operating current from 60µA to 100mA
Low dynamic output resistance of 50m
±0.5% trimmed voltage reference
10mV typ. V
Surface mount 3 or 5 pin SOT-23 or through­hole 3 pin TO-92 packages
deviation, from -40 to +105°C
REF
Applications
Notebook computers
Isolated feedback in switching power supplies
Adjustable and programmable supplies
Linear regulators (External Reference)
Instrumentation
Medical Electronics*
Global voltage reference for multiple power supplies
Preliminary Information
Typical Application
R
IN
AHK432
432.2001.11.0.96 1
L
OUT
R1
Adjustable regulator:
R1 + R2
OUT = V
R2
REF
R2
AHK432
Adjustable Low Voltage Shunt Regulator
Absolute Maximum Ratings (T
=25°C unless otherwise noted)
A
Symbol Description Value Units
V
Z
I
Z
I
REF
T
J
Θ
JA
P
D
T
LEAD
Note: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at con­ditions other than the operating conditions specified is not implied. Only one Absolute Maximum rating should be applied at any one time.
Electrical Characteristics (T
Symbol Description Conditions min typ max min typ Max min typ max Units
REF
V
DEV
V
/V
REF
Z
I
REF
I
REF(DEV)
I
Z(OFF)
R
Z
I
Z(MIN)
Cathode Voltage 20 V Continuous Cathode Current 100 mA Reference Current 3 mA Operating Junction Temperature Range -40 to 150 °C
Maximum Thermal Resistance
Maximum Power Dissipation
TO-92 160
SOT-23-3, SOT-23-5 410
TO-92 780
SOT-23-3, SOT-23-5 300
Maximum Soldering Temperature (at Leads) 260 °C
=25°C unless otherwise noted)
J
AHK432 0.5% AHK432 1.0% AHK432 2.0%
VZ=V
Reference
Voltage
V
Te mp TA=-40 to +105°C, 10 25 10 25 10 25 mV
REF
Deviation VZ=V
Ratio of IZ=10mA, -1.0 -2.7 -1.0 -2.7 -1.0 -2.7 mV/V
Change in V
to Change in (test circuit 2)
Cathode Voltage
Reference R1=10kΩ , 0.15 0.5 0.15 0.5 0.15 0.5 µA
Input Current R2=, IZ=10mA
I
Te mp TA=-40 to +105°C 0.1 0.4 0.1 0.4 0.1 0.4 µA
REF
Deviation R1=10k , R2=,
Off State V
Cathode Current (test circuit 3) VZ=16V 0.04 0.5 0.04 0.5 0.04 0.5
Dynamic f<1kHz, VZ=V
Output IZ=100mA to 100mA
Impedance (test circuit 1)
Minimum VZ=V
Operating (test circuit 1)
Current
REF
VZ=16V to V
REF
IZ=10mA
(test circuit 1)
, IZ=10mA
REF
(test circuit 1)
(test circuit 2)
IZ=10mA
(test circuit 2)
=0V VZ=6V 0.04 0.1 0.04 0.1 0.04 0.1 µA
REF
REF
TA=25°C 1.234 1.240 1.246 1.228 1.240 1.252 1.215 1.240 1.265
TA=-40
to +105°C
REF
, 0.05 0.2 0.05 0.2 0.05 0.2
REF
1.222 1.258 1.215 1.265 1.200 1.280
60 80 60 80 60 80 µA
°C/W
mW
VV
2 432.2001.11.0.96
Test Circuits
Test Circuit 1 Test Circuit 2 Test Circuit 3
AHK432
Adjustable Low Voltage Shunt Regulator
IN
OUT
I
Z
I
REF
IN
I
Z
I
OUT
REF
IN
I
Z(off)
OUT
432.2001.11.0.96 3
Typical Characteristics
(Unless otherwise noted, TA= 25°C, IZ= 10mA)
AHK432
Adjustable Low Voltage Shunt Regulator
Cathode Current vs. Cathode Voltage
15
10
5
0
-5
-10
Cathode Current (mA)
-15
-1 -0.5 0 0.5 1 1.5
Cathode Voltage ( V)
Reference Voltage vs. Temperature
1.252
1.248
1.244
1.24
1.236
Reference Voltage (V)
1.232
-50 -25 0 25 50 75 100 125
Junction Temperature (°C)
IZ=10mA
Cathode Current vs. Cathode Voltage
200
150
100
50
0
-50
-100
-150
Cathode Current (µA)
-200
-1 -0.5 0 0.5 1 1.5
Cathode Voltag e (V)
Reference Current vs. Temperature
180
160
140
120
100
80
60
40
20
0
Reference Current (nA)
-50 -25 0 25 50 75 100 125
Junction Temperat ure (°C)
IZ=10mA R R2=Open
=10k
1
Cathode Current vs. Temperature
80
VZ=5V
70
V
=0V
REF
60
(Off-state)
50
40
30
20
10
Cathode Current (nA)
0
-50 -25 0 25 50 75 100 125
Junction Temperature (°C)
Ratio of ∆V
0
-100
-200
-300
-400
Ratio (µV/V)
-500
-600
-50 -25 0 25 50 75 100 125
REF
/ V
vs. Temperature
Z
IZ=10mA dVZ=V
Junction Temperature (°C)
REF
to 16V
4 432.2001.11.0.96
AHK432
Adjustable Low Voltage Shunt Regulator
(Unless otherwise noted, T
= 25°C, IZ= 10mA)
A
Cathode Impedance vs. Temperature
16%
12%
8%
4%
0%
Normaliz ed Impedance
-4%
-50 -25 0 25 50 75 100 125
Junct ion Temperature (°C)
Gain and Phase vs. Frequency
120
100
80
60
40
Gain (dB)
20
0
-20
1.E+01 1.E+02 1.E+0 3 1.E+0 4 1.E+05 1.E+0 6
Frequency (Hz)
180
150
120
-30
Impedance vs. Frequency
10
1
0.1
Impedance ()
0.01
1.E+01 1.E+02 1.E+03 1.E+04 1.E+05 1.E+0 6
Frequency ( Hz )
V
OUT
V
IN
90
60
30
0
13.7k
8.25k
169
AHK432
5V
Test Circuit for Voltage
Gain and Phase
Stability Boundary
1k
100
I
80
Stable
60
40
Current (mA)
20
0
10.E+0 100.E+0 1. E+3 10.E+3 100.E+3 1.E+6 10.E+6
Unstable
Load Capacitance (pF)
Stable
V
AHK432
REF=VZ
Test Circuit for Stability
432.2001.11.0.96 5
Z
R1=10k
C
L
R2
Adjustable Low Voltage Shunt Regulator
Functional Block Diagram Symbol Diagram
CATHODE
CATHODE
REF
REF
=1.24V
V
REF
ANODE
ANODE
AHK432
Ordering Information
Package
SOT-23-3 N/A N/A N/A
SOT-23-5 Bulk N/A N/A N/A
TO-92 AHK432ILY-.5-B1 AHK432ILY-1-B1 AHK432ILY-2-B1
SOT-23-3
SOT-23-5 AHK432IGV-.5-T1 AHK432IGV-1-T1 AHK432IGV-2-T1
TO-92 Ammo AHK432ILY-.5-A1 AHK432ILY-1-A1 AHK432ILY-2-A1
* LIFE SUPPORT POLICY AnalogicTech's PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYS­TEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF Advanced Analogic Technologies Inc. As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sus­tain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea­sonably expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Bulk or Tape
and Reel
Tape and Reel
0.5% 1.0% 2.0%
AHK432IGY-.5-T1 AHK432IGY-1-T1 AHK432IGY-2-T1
Tolerance
6 432.2001.11.0.96
Pin Configuration
AHK432
Adjustable Low Voltage Shunt Regulator
3-lead SOT-23
(Top View)
Reference
Cathode
1
3
Anode
2
Package Information
TO-92 M
L
E
H
D
01(2X)
02(2X)
5-lead SOT-23
(Top View)
N/C
1
Anode
5
2
N/C
3
4
Cathode
e
A
Reference
Dim
Reference
Cathode
Millimeters Inches
Min Max Min Max
Anode
TO-92
(Top View)
1 2 3
A 2.40 2.60 0.094 0.102
G
F
A1 0.70 0.90 0.028 0.036
b 0.35 0.55 0.014 0.022 C 0.00 0.00 0.000 0.000
b
R2.00
A1
D 2.80 3.20 0.110 0.126 E 3.80 4.20 0.149 0.165 e 0.00 0.00 0.000 0.000 F 1.91 2.31 0.075 0.091 G 3.35 3.75 0.132 0.148
C
H 0.00 0.15 0.000 0.006 L 13.80 14.20 0.543 0.559
θ12° 2° θ25° 5°
Note: PACKAGE OUTLINE EXCLUSIVE OF ANY MOLD FLASHES AND BURR DIMENSION
432.2001.03.0.95 7
SOT-23-3
AHK432
Adjustable Low Voltage Shunt Regulator
A2
A2
D
S1
Dim
Millimeters Inches
Min Max Min Max
A .887 1.02 0.034 .040 A1 .013 0.10 0.0005 .004 A2 - - - -
E
H
b 0.37 0.51 0.015 0.020 C 0.085 0.180 0.003 0.007 D 2.80 3.04 0.110 0.120
S
e
E 1.20 1.40 0.047 0.055
e 1.78 2.05 0.070 0.080 H 2.10 2.64 0.083 0.104
L - 0.69 - 0.027 S 0.45 0.60 0.018 0.024
S1 0.89 1.03 0.035 0.040
A
1
A1
b
Q
C
L
SOT-23-5
e
S1
θ1
Note:
1. PACKAGE BODY SIZE EXCLUDE MOLD FLASH PROTRUSIONS OR GATE BURRS.
2. TOLERANCE ±0.1000 mm (4mi) UNLESS OTHER­WISE SPECIFIED
3. COPLANARITY: 0.1000
4. DIMENSION L IS MEASURED IN GAGE PLANE
Dim
Millimeters Inches
Min Max Min Max
A 0.95 1.45 0.037 0.057
A1 0.05 0.15 0.002 0.006
H
E
A2 0.90 1.30 0.035 0.051
b 0.35 0.50 0.014 0.019
c 0.08 0.20 0.003 0.078 D 2.84 3.00 0.112 0.112 E 1.50 1.70 0.059 0.067
D
e 1.90 0.0748 H 2.60 3.00 0.102 0.118
L 0.35 0.55 .0137 .0216
A
A1
S
b
L
S 0.47 0.55 0.019 .0216
S1 .95 0.037
c
Θ 10° 10°
Advanced Analogic Technologies, Inc.
1250 Oakmead Parkway, Suite 310, Sunnyvale, CA 94086 Phone (408) 524-9684 Fax (408) 524-9689
8 432.2001.11.0.96
Loading...