Wide Bandwidth Strain Gage Input
FEATURES
Wideband (20 kHz) single-channel signal conditioning module.
Module Bandwidth is user-selectable between 20 kHz and 100Hz, with user-supplied filter caps installed in the optional AC1310 ranging card.
Interfaces, amplifies, and filters signals from balanced 4-arm full-bridge strain-gage bridges.
Module provides simultaneous precision voltage and current outputs.
Module circuitry can withstand 130v rms at the input screw­terminals
All 3B18 series modules are mix-and-match and Hot Swappable
APPLICATIONS
Industrial signal conditioning Industrial signal isolation Industrial signal filtering
PRODUCT OVERVIEW
The 3B Series of Signal Conditioning I/o Subsystems provide a low-cost, versatile method of transferring analog transducer signals to a data acquisition, monitoring or control system without the inherent noise, non-linearity, drift and extraneous voltages. The modules are designed to directly accept analog signals from Thermocouples, RTD’s, AC and DC Strain Gages, Torque Transducers, Frequency Transducers, LVDTs, millivolt or process current signals. The modules amplify, isolate, linearize and convert the transducer output signals to standardized analog inputs for high-level analog I/O subsystems. The 3B Series Subsystem consists of a 10” relay rack with universal mounting backplane and a family of plug-in (up to 16 per rack) input and output signal conditioning modules.
Eight and four channel backplanes are also available. Each backplane incorporates screw terminals for sensor inputs and current outputs and a 26-pin connector for high-level single­ended voltage outputs to the user’s equipment.
The input modules feature complete signal conditioning circuitry optimized for specific sensors or analog signals and provide two simultaneous high-level analog outputs: 0 to +10V
10V) and 4-20 mA (or 0-20 mA).
(or +
3B18
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 3B18 Functional Block Diagram
Output modules accept 0 to +10V (or +10V) single-ended signals and provide an isolated 4-20 mA (or 0-20 mA) process signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring.
The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applications. Some typical uses are in microcomputer-based data acquisition systems, programmable controllers, analog recorders, dedicated control systems, and any other applications where monitoring of temperature, pressure, flow and analog signals are required. Since each input module features two simultaneous outputs, the voltage output can be used to provide an input to a microprocessor-based data acquisition or control system while the current output can be used for analog transmission, operator interface, or an analog backup system.
Each input module is a single-channel signal conditioner which plugs into a socket on the backplane and accepts its signal from the input screw terminals. All input modules provide input protection, amplification and filtering of the input signal, accuracy of + modules), and feature two high-level analog outputs that are compatible with most process instrumentation. The isolated input modules also provide +
The choice of a specific 3B module depends upon the type of input signal. Input modules are available to accept millivolt, volt, process current, thermocouple, RTD, AC and DC strain gage, frequency and LVDT inputs. The voltage output of each module is available from the system I/O connector while the current output is available on the output screw terminals.
0.1%, low drift of +1 uV/oC (low-level input
1500 V peak isolation.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.326.8703 © 2004 Analog Devices, Inc. All rights reserved.
www.analog.com
GENERAL DESCRIPTION
The 3B18 is a wideband (20kHz) single-channel signal conditioning module which interfaces, amplifies, and filters signals from balanced 4-arm full-bridge strain-gage bridges with a resistance from 100 to 10 k, provid ing simult ane ous precision voltage and current outputs. The module provides two user-selectable (via front-panel switches) bridge excitation voltages: +10 V for bridges with a load impedance down to 300W or +3.33V for 120W bridges or others below 300W. Module bandwidth is also user-selectable between 20 kHz and 100 Hz, with user-supplied filter capacitors installed in the optional AC1310 ranging card. The 3B18 protects the computer side from damage due to field-side over-voltage faults up to 130V rms. In addition, the current output withstands 130V rms without damage and interfaces user equipment through screw terminals located on the 3B Series backplane. The 3B18 is a plug-in, mix-and-match, hot-swappable module which is easily field calibrated via front-panel zero and span adjustments for
.
3B18
both voltage and current outputs.
3B Series Custom-Ranging Program – Externally­programmable Model 3B18-00, enables the user to configure a special input range by using the optional plug-on AC1310 ranging card, which houses user-supplied resistors to determine zero and span. To facilitate selecting resistors, a Windows program, 3B-CUSTOM, calculates resistor values based on the user-desired input/output ranges.
A chopper-stabilized low-drift (+ assures long-term stability. For user convenience, the zero and span can be factory configured to meet custom range needs (Model 3B18-CUSTOM) or can be externally programmed (Model 3B18-00) via user supplied resistors inserted in the optional AC1310 plug-on ranging card.
1uV/oC) input amplifier
.
Figure 2
Rev. 0 | Page 2 of 8
3B18 Models Available
Model Input
3B18-00 Full
3B18-01 Full
3B18-02 Full
3B18-Custom Full Bridge * +10.0 V or +3.33 V * *
1
Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
2
Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
Bridge
Bridge
Bridge
Bridge
3B18 Specifications (typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description Model 3B18
Standard Range ±30 mV (3 mV/V sensitivity @ V
Custom Ranges ±5 mV to ±500
Voltage (RL > 2 KΩ) Current (RL = 0 to 850Ω)1 Maximum Current Output Span 0 mA to 31 mA
Initial @ +25°C ±0.1% Span Nonlinearity2 ±0.01% Span
Voltage Output Zero ±3 µV/°C (RTI) Span ±25 ppm of Reading/°C Current Output3 Zero ±25 ppm of Span/°C Span ±25 ppm of Reading/°C
Input
Range
Externally
Programmable
-30 mV to +30 mV +10.0 V or +3.33 V 3 mV/V @ 10 Vexc -10 V to +10 V &
-10 mV to +10 mV +10.0 V or +3.33 V 3 mV/V @ 3.33 Vexc -10 V to +10 V &
3
Excitation1 Sensitivity Output
+10.0 V or +3.33 V Externally
Input Range
±10 mV (3 mV/V sensitivity @ V
Output Range
-10 V to +10 V 4 mA to 20 mA or 0 mA to 20 mA
Accuracy2
Stability vs. Temperature
Programmable3
= +10V)
exc
= +3.33 V)
exc
Ranges
-10 V to +10 V & 0 mA to 20 mA
0 mA to 20 mA
0 mA to 20 mA
3B18
Bridge Excitation
Voltage user-selectable +10 V or +3.33 V Voltage, tol er an ce ±2% Voltage vs. Temperature ±0.0015%/°C
Bridge Resistance Range
V
= +10.0 V
exc
300 to 1 k
Rev. 0 | Page 3 of 8