5 kV rms Signal Isolated High Speed
TxD
RxD
ISOLATION
BARRIER
GND
1
DECODE
DECODE
DECODE
V
DD2SENSE
ENCODE
ENCODE
ENCODE
V
REF
V
DD1
ADM3054
VOLTAGE
REFERENCE
CAN TRANSCEIVE R
LOGIC SIDE BUS SIDE
V
DD2
CANL
CANH
DIGITAL ISOLATION
iCoupler
®
R
D
V
DD2
VOLTAGE
SENSE
THERMAL
SHUTDOWN
GND
2
10274-001
CAN Transceiver with Bus Protection
Data Sheet
FEATURES
5 kV rms signal isolated CAN transceiver
5 V or 3.3 V operation on V
5 V operation on V
V
to detect loss of power on V
DD2SENSE
DD2
Complies with ISO 11898 standard
High speed data rates of up to 1 Mbps
Short-circuit protection on CANH and CANL against shorts to
power/ground in 24 V systems
Unpowered nodes do not disturb the bus
Connect 110 or more nodes on the bus
Thermal shutdown protection
High common-mode transient immunity: >25 kV/µs
Safety and regulatory approvals
UL recognition (pending)
5000 V rms for 1 minute per UL 1577
VDE Certificates of Conformity (pending)
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12
V
= 846 V peak
IORM
Industrial operating temperature range: −40°C to +125°C
Wide-body, 1 6-lead SOIC package
DD1
DD2
GENERAL DESCRIPTION
The ADM3054 is a 5 kV rms signal isolated controller area
network (CAN) physical layer transceiver. The ADM3054
complies with the ISO 11898 standard.
The device employs Analog Devices, Inc., iCoupler® technology
to combine a 3-channel isolator and a CAN transceiver into a
single package. The logic side of the device is powered with a
single 3.3 V or 5 V supply on V
5 V supply on V
only. Loss of power on the bus side (V
DD2
can be detected by an integrated V
The ADM3054 creates an isolated interface between the CAN
protocol controller and the physical layer bus. It is capable of
running at data rates of up to 1 Mbps.
The device has integrated protection on the bus pins, CANH
and CANL against shorts to power/ground in 24 V systems.
The device has current-limiting and thermal shutdown features
to protect against output short circuits and situations where the
bus might be shorted to ground or power terminals. The part is
fully specified over the industrial temperature range and is
available in a 16-lead, wide-body SOIC package.
and the bus side uses a single
DD1
signal.
DD2SENSE
DD2
)
APPLICATIONS
CAN data buses
Industrial field networks
FUNCTIONAL BLOCK DIAGRAM
Figure 1
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third par ties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113 ©2011 Analog Devices, Inc. All rights reserved.
www.analog.com