ANALOG DEVICES ADIS16220 Service Manual

Programmable
A
A

FEATURES

Digital ±70 g accelerometer/vibration sensing 22 kHz sensor resonance
100.2 kSPS sample rate SPI-compatible serial interface Programmable data capture function:
3 channels, 1024 samples each
1 accelerometer/2 auxiliary ADCs (AIN1, AIN2) Manual trigger for user initiation Automatic trigger for periodic data capture Event trigger for condition-driven capture
Digital temperature sensor output Digitally controlled sample rate Digitally controlled frequency response 2 auxiliary digital I/Os Digitally activated self-test Digitally activated low power mode Serial number and device ID Single-supply operation: 3.15 V to 3.6 V Operating temperature range: −40°C to +125°C
9.2 mm × 9.2 mm 16-terminal LGA

APPLICATIONS

Vibration analysis Shock detection and event capture Condition monitoring Machine health Instrumentation, diagnostics Safety, shut-off sensing Security sensing, tamper detection
Digital Vibration Sensor
ADIS16220

GENERAL DESCRIPTION

The ADIS16220 iSensor® is a digital vibration sensor that com­bines industry-leading iMEMS® sensing technology with signal processing, data capture, and a convenient serial peripheral interface (SPI). The SPI and data buffer structure provide convenient access to wide-bandwidth sensor data. The 22 kHz sensor resonance and 100.2 kSPS sample rate provide adequate response for most machine-health applications. The averaging/ decimating filter provides optimization controls for lower bandwidth applications.
An internal clock drives the data sampling system, which fills the buffer memory for user access. The data capture function has three different trigger modes. The automatic data collection allows for periodic wake-up and capture, based on a programma­ble duty cycle. The manual data capture mode allows the user to initiate a data capture, providing power and read-rate optimiza­tion. The event capture mode continuously updates the buffers and monitors them for a preset trigger condition. This mode captures pre-event data and post-event data and produces an alarm indicator for driving an interrupt.
The ADIS16220 also offers a digital temperature sensor, digital power supply measurements, and peak output capture.
The ADIS16220 comes in a 9.2 mm × 9.2 mm × 3.9 mm LGA package that meets the Pb-free solder reflow profile require­ments per JEDEC J-STD-020 and has an extended operating temperature range of −40°C to +125°C.

FUNCTION BLOCK DIAGRAM

VDDRSTDIO1 DIO2
USER
OUTPUT
DATA
POWER
MANAGEMENT
SPI
PORT
GND
CS SCLK DIN DOUT
07980-001
ALARMSI/OSELF-TEST
MEMS
SENSOR
TEMP
SENSOR
IN1
IN2
ADIS16220
VREF
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners.
CLOCK
CONTROLLER
FILTER
CAPTURE
BUFFER
Figure 1.
CONTROL
REGISTERS
REGISTERS
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 ©2009 Analog Devices, Inc. All rights reserved.