ANALOG DEVICES 5B34 Service Manual

Isolated Linearized RTD Input
www.BDTIC.com/ADI
FEATURES
Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD
measurements are provided by the 5B35). Generates an output of 0 to +5V. Module circuitry can withstand 240v rms at the input screw-
terminals. All 5B34 series modules are mix-and-match and Hot
Swappable.
APPLICATIONS
Industrial signal conditioning Industrial signal isolation Industrial signal filtering Signal Linearization
PRODUCT OVERVIEW
The 5B Series represents an innovative generation of low cost, high performance plug-in signal conditioners. Designed for industrial applications, these modules incorporate highly reliable transformer-based isolation and automated surface­mount manufacturing technology. They are compact, economical components whose performance exceeds that available from more expensive devices. Combining 1500 V rms continuous isolation, +0.05% calibrated accuracy, small size and low cost, the 5B Series is an attractive alternative to expensive signal conditioners and in-house designs
All modules are potted and identical in pin-out and size (2.27” x
2.32” x 0.595”). They can be mixed and matched, permitting users to address their exact needs, and may be “hot swapped without disturbing field wiring or power. The isolated input modules provide 0 to +5V or +5V outputs and accept J, K, T, E, R, S, N, or B type thermocouples.
These modules feature complete signal conditioning functions including 240 V rms input protection, filtering, chopper stabilized low drift +1 uV/oC amplification, 1500 V rms isolation, and sensor excitation when required.
All modules feature excellent common mode rejection and meet industrial transient surge withstand specifications.
5B34
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 5B34 Functional Block Diagram
There are also a number of backplanes and mounting sockets which provide a complete signal conditioning solution for end users. Each backplane incorporates screw terminals for field wiring inputs and outputs and cold junction sensors for thermocouple applications.
These signal conditioners are designed to provide an easy and convenient solution to signal conditioning problems of both designers and end users in measurement and control applications. Typical uses include microcomputer-based measurement systems, standard data acquisition systems, programmable controllers, analog recorders and dedicated control systems. The 5 B series modules are ideally suited to applications where monitoring and control of temperature, pressure, f low, rotation and other analog signals are required.
The 5B Series modules and backplanes are approved by Factory Mutual (FM) and the 5B Series modules are approved by the Canadian Standards Association (CSA) for use in Class 1, Division 2, Groups A, B, C, and D locations. These approvals certify that the 5B Series is suitable for use in locations where a hazardous concentration of flammable gas may exist only under fault conditions of operation. Equipment of this category is called “non-incendive” and they need no special enclosures or other physical safeguards. The 5B series modules and backplanes have been tested and passed the stringent heavy industrial requirements of the EU’s electromagnetic compatibility (ENC) directive – EN50082-1 and EN50081-2. When used according to installation directions (refer to 5B series User Manual), any errors caused by EMI/RFI interference will be less than 0.1% of the full scale 5B measurement range for field strengths up to 10 V/M and frequencies up to 1 GHz.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.326.8703 © 2004 Analog Devices, Inc. All rights reserved.
www.analog.com
www.BDTIC.com/ADI
GENERAL DESCRIPTION
The 5B34 is a single-channel signal conditioning module that amplifies, protects, filters, linearizes, and isolates a wide variety of two and three-wire RTDs. For true four-wire RTD measurements please refer to the 5B35 model.
The 5B34 protects the computer side from damage due to field­side over-volatge faults. The module withstands 240 V rms at the input terminals without damage thereby shielding the internal computer-side circuitry from field-side over-voltage conditions. In addition, the 5B34 is mix-and-match and hot swappable with all other 5B Series input modules, so can be inserted or removed from any socket in the same backplane without disrupting system power.
Two identical sources provide excitation current for the RTD. For three-wire RTDs, the second current flows through the third RDT lead so as to cancel the effects of (equal) lead resistance; this current also flows through a stable resistor laser­trimmed to the RTD value that sets the differential amplifier input and (module) output to zero volts at that scale point. The current sources and the amplifier input are protected to withstand input over-voltage up to 240 V rms.
A differential chopper-stabilized input amplifier provides stable gain and exceptionally low drift. This allows the use of very low RTD excitation current to minimize self-heating and preserve
.
5B34
measurement accuracy. Along with module gain and zero settings, a feedback linearizer is laser-trimmed. Custom versions of 5N34 can be laser-trimmed to meet special requirements.
Internal multi-pole low-pass filtering with a four-Hz cutoff (­3dB) enhances normal-mode (noise on signal) and common­mode (noise on signal return) rejection at 50/60 Hz, enabling accurate measurement of small signals in high electrical noise.
Signal isolation by transformer coupling uses a proprietary modulation technique for linear, stable and reliable performance. The differential input circuit on the field side is fully floating, eliminating the need for any input grounding. A demodulator on the computer side of the signal transformer recovers the original signal, which is then filtered and buffered to provide a low-noise, low-impedance output signal. The output common must be kept within +
A series output switch eliminates the need for external multiplexing in many applications. The switch is turned on by an active-low enable input. If the switch is to be on at all times, the enable-input should be grounded to power common as it is on the 5B01 and 5B08 backplanes.
3V of power common.
Figure 2
.
Rev. 0 | Page 2 of 8
www.BDTIC.com/ADI
5B34—SPECIFICATIONS
5B34 Models Available
Model Input Range Output Range Accuracy
5B34-01
5B34-02 0°C to +100°C (+32°F to 212°F) 0 V to +5 V ±0.13°C
5B34-03 0°C to +200°C (+32°F to 392°F) 0 V to +5 V ±0.26°C
5B34-04 0°C to +600°C (+32°F to 1112°F) 0 V to +5 V ±0.78°C
5B34-C-01
5B34-C-02
5B34-N-01
5B34-Custom
100 Platinum,
-100°C to +100°C (-148°F to +212°F)
10 Copper,
0°C to +120°C (10 @ 0°C) (+32°F to +248°F)
0°C to +120°C (10Ω @ 25°C)(+32°F to +248°F)
120 Nickel, * = 0.00672
0°C to +300°C (+32°F to +572°F)
= 0.00385*
= 0.004274
* *
5B34
0 V to +5 V ±0.32°C
0 V to +5 V ±0.23°C
0 V to +5 V ±0.23°C
0 V to +5 V ±0.40°C
* Custom Input/Output ranges are available including versions for the 100 Platinum RTD with Refer to configuration guide.
5B34 Specifications
(typical @ +25°C and Vs = +5 V dc)
Description Model 5B34
Input Ranges
Standard Ranges Refer to Model Table
Custom Ranges
Output Range (R
Initial @ +25°C
Conformity Error
Input Offset vs. Temperature ±0.02°C/°C
Output Offset vs. Temperature ±20 µV/°C
Gain vs. Temperature ±0.005% of Reading/°C
Input Bias Current ±3 nA
> 50 kΩ)
L
3
±0.05% Span
-200°C to +850°C (100 Platinum)
-80°C to +320°C (120Ω Nickel)
-100°C to +260°C (10Ω Copper)
0 V to +5 V
Accuracy2
±0.05% Span ±0.04 * ±0.05 (Rz
=0.003916.
1
)
Input Resistance
Power On
Power Off
Overload
Input, 0.1 Hz to 10 Hz Bandwidth 0.2 µV rms
Output, 100 kHz Bandwidth 200 µV rms
Bandwidth, -3 dB 4 Hz
5 M
40 k
40 k
Noise
Rev. 0 | Page 3 of 8