AMX RDM-ZC50 User Manual

Installation Sheet
RDM-ZC50 Zero Cross Module
6000 W
The RDM-ZC50 Zero Cross Module is a 6000 W solid-state zero-cross relay built for extra large loads. It is designed for use with the RDA series of enclosures, in an AMX Lighting™ modular digital dimming system. The RDM-ZC50 module's 120 VAC and 277 VAC ratings are CE, UL, and C-UL approved.
Mounting points
Line in (hot)
Load out
Zero cross relay
Low-voltage control wiring: 4-pin controller to AMX Lighting master controller
FIG. 1 RDM-ZC50
High-voltage connections
120-277 VAC, 6000 W

Suggested Switched Loads

• Incandescent
• Electronic transformers
• HID ballast
• Fluorescent ballast

Specifications

• Dimensions (HW): 10.00" x 2.75" (25.40 cm x 6.99 cm)
• Non-phase dependant
• Use 75°C (167°F) copper conductors only
• Torque terminals to 16 in-lbs. (7.25 kg-m)
• Max. wire size: 6 AWG; 14 AWG min.
• Wire stripping length: 0.35" (9 mm)
• Weight: 1.0 lb. (0.45 kg)
• BTU/hr: 400
• Control current: 45 mA @ 12 VDC

Caution: Pre-Installation Notes

• All Class 1 wiring must be connected to proper terminals.
• All control wiring must be connected to proper terminals.
• Disconnect power while installing or connecting the unit.
• Keep top and bottom air vents clear at all times.
• Test loads for shorts before connecting.
• Run all low-voltage and control wires away from heat producing parts of the dimmer.
• Each dimming circuit must have a separate neutral connection.
• All electrical ratings are for continuous duty.
• AC lighting loads only.
• For indoor use only.
• This module may require extra power from the AXlink connection or an external power supply connected to the control card.

Connecting the RDM-ZC50 to the AMX Lighting Master

Pin 4 (GND) Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
RDM-ZC50 4-pin module connector
3 (-)
1 (+)
4-pin plug from RDM series module
NOTE: The 4-pin plugs from the module connector to the 4-pin connector on the master (black plug cover facing up).
FIG. 2 RDM-ZC50 connections

Lighting Application Drawing

All neutrals are common to the Neutral block in the enclosure. Provide a separate neutral for each load.
Neutral
Line in (HOT)
Circuit breaker panel
FIG. 3 RDM-ZC50 wiring configuration
Load
Fluorescent Lighting
Ballast
Load
Neutral
Neutral
Load
Neon lights
(cold-cathode, on/off)
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
The AMX logo is a trademark of AMX Corporation. AMX Cor poration reserves the right to alter specifications without notice at any time.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.2 22.0193 • fax 469.624.7153 • technical suppor t 800.932.6993
043-019-2214 8/01 ©2001 AMX Corporation. All rights re served.
Loading...