This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which include AMX Dealers, Distributors, VIP’s or other AMX authorized entity.
AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase, with the following exceptions:
Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay compo­nents are warranted for a period of one (1) year.
Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year.
AMX lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX lighting products are under warranty. AMX also guarantees the control of dimmable loads that are properly con­nected to our lighting products. The dimming performance or quality there of is not guaranteed, impart due to the random combi­nations of dimmers, lamps and ballasts or transformers.
AMX software is warranted for a period of ninety (90) days.
Batteries and incandescent lamps are not covered under the warranty.
AMX AutoPatch Epica, Modula, Modula Series4, Modula CatPro Series and 8Y-3000 product models will be free of defects in materials and manufacture at the time of sale and will remain in good working order for a period of three (3) years following the date of the original sales invoice from AMX. The three-year warranty period will be extended to the life of the product (Limited Lifetime Warranty) if the warranty card is filled out by the dealer and/or end user and returned to AMX so that AMX receives it within thirty (30) days of the installation of equipment but no later than six (6) months from original AMX sales invoice date. The life of the product extends until five (5) years after AMX ceases manufacturing the product model. The Limited Lifetime Warranty applies to products in their original installation only. If a product is moved to a different installation, the Limited Lifetime Warranty will no longer apply, and the product warranty will instead be the three (3) year Limited Warranty.
All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number.
AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Autho­rized Partner for a third party.
This Limited Warranty does not apply to (a) any AMX product that has been modified, altered or repaired by an unauthorized agent or improperly transported, stored, installed, used, or maintained; (b) damage caused by acts of nature, including flood, erosion, or earth­quake; (c) damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance, including brownouts, sags, spikes, or power outages; or (d) damage caused by war, vandalism, theft, depletion, or obsolescence.
This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury.
Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of inci­dental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights.
EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. EXCEPT AS OTHERWISE LIMITED BY APPLICABLE LAW, AMX RESERVES THE RIGHT TO MODIFY OR DISCONTINUE DESIGNS, SPECIFICATIONS, WARRAN­TIES, PRICES, AND POLICIES WITHOUT NOTICE.
Table of Contents
Table of Contents
NOVARA ControlPads ........................................................................................1
Overview .................................................................................................................. 1
Product Specifications ............................................................................................. 2
Mounting Specifications - 8-Button ControlPads ...................................................... 4
CP-1008-US .................................................................................................................... 4
Minimum Internal Clearance for 1-Gang US Conduit Boxes ............................................ 4
CP-1008-UK .................................................................................................................... 5
CP-1008-EU .................................................................................................................... 6
Mounting Specifications - 16-Button ControlPads .................................................... 7
CP-1016-US .................................................................................................................... 7
Minimum Internal Clearance for 3-Gang US Conduit Boxes ............................................ 7
CP-1016-UK/EU .............................................................................................................. 8
Wiring and Connections............................................................................................ 9
NOVARA ControlPads - Rear Panel Connectors .............................................................. 9
Relay 1 / Relay 2 Connectors......................................................................................... 10
RS232 Out Connector ................................................................................................... 11
IR Out Connector .......................................................................................................... 11
Input Connector ............................................................................................................ 12
Power Supply Connector............................................................................................... 12
USB Program Port ......................................................................................................... 13
Button Layout ......................................................................................................... 13
NOVARA AxLink KeyPads ................................................................................15
Overview ................................................................................................................ 15
Product Specifications ........................................................................................... 16
Mounting Specifications - 8-Button KeyPads .......................................................... 17
SP-08-AX-US................................................................................................................. 17
Minimum Internal Clearance for 1-Gang US Conduit Boxes .......................................... 17
SP-08-AX-UK ................................................................................................................ 18
SP-08-AX-EU ................................................................................................................ 19
Mounting Specifications - 16-Button KeyPads ........................................................ 20
SP-16-AX-TR-US ........................................................................................................... 20
Minimum Internal Clearance for 3-Gang US Conduit Boxes .......................................... 20
SP-16-AX-TR-UK ........................................................................................................... 21
Wiring and Connections.......................................................................................... 22
ControlPads - Rear Panel Connectors............................................................................ 22
RS-232 Connections ..................................................................................................... 22
Power Supply Connector............................................................................................... 22
Novara ControlPads & KeyPads
i
Table of Contents
Daisy-Chaining KeyPads (RS232) ................................................................................... 23
Daisy-Chaining KeyPads (AxLink)................................................................................... 23
Button Layout ......................................................................................................... 24
Setting DIP Switches to Assign Alternate Button Numbering ................................ 24
Alternate Button Numbering: 8-Button KeyPads .......................................................... 24
Alternate Button Numbering: 16-Button KeyPads ........................................................ 25
Setting the AxLink Address DIP Switch .................................................................. 25
Setting the AxLink Device Address ............................................................................... 25
NOVARA KeyPads ............................................................................................27
Overview ................................................................................................................ 27
Product Specifications ........................................................................................... 28
Mounting Specifications - 8-Button KeyPads .......................................................... 29
SP-08-US ....................................................................................................................... 29
Minimum Internal Clearance for 1-Gang US Conduit Boxes .......................................... 29
SP-08-UK ...................................................................................................................... 30
SP-08-EU ...................................................................................................................... 31
Mounting Specifications - 16-Button KeyPads ........................................................ 32
SP-16-US ....................................................................................................................... 32
Minimum Internal Clearance for 3-Gang US Conduit Boxes .......................................... 32
SP-16-UK/EU ................................................................................................................ 33
Wiring and Connections.......................................................................................... 34
ControlPads - Rear Panel Connectors ............................................................................ 34
RS-232 Connections ..................................................................................................... 34
Power Supply Connector............................................................................................... 34
Daisy-Chaining KeyPads ................................................................................................ 35
Button Layout ......................................................................................................... 35
Setting DIP Switches to Assign Alternate Button Numbering ................................ 36
Alternate Button Numbering: 8-Button KeyPads .......................................................... 36
Alternate Button Numbering: 16-Button KeyPads ........................................................ 36
Button Labelling ...............................................................................................37
Overview ................................................................................................................ 37
Installing Acetate Button Labels and Key Caps - READ THIS FIRST!.............................. 37
Removing/Replacing Button Labels ........................................................................ 39
Disassembling the NOVARA Keypad ............................................................................ 39
Replacing Key Caps / Button Labels .............................................................................. 40
Re-Assembling the Keypad ........................................................................................... 41
Exploded View - 8-Button US Version .......................................................................... 41
Exploded View - 8-Button UK/EU Version .................................................................... 42
Exploded View - 16-Button US/UK/EU Version ............................................................ 42
ii
Novara ControlPads & KeyPads
Table of Contents
AMX NOVARA DCS1000 Device Configuration Software ................................43
Installing the AMX NOVARA DCS1000 Application................................................ 43
Launching AMX NOVARA DSC1000 ............................................................................. 44
Overview ................................................................................................................ 45
Downloading the Program to the ControlPad ........................................................ 46
Specifying Button Feedback ................................................................................... 46
Adding Feedback to a Button Script (Example) ............................................................ 46
Button Feedback - On / All Buttons Off ........................................................................ 48
Button Feedback - On / Group Off ............................................................................... 48
Testing Grouped Feedback ........................................................................................... 49
Delay Time.............................................................................................................. 49
Adding Delay Time to a Script (Example)...................................................................... 49
RS232 Functions ..................................................................................................... 50
Opening RS232 Library Files ......................................................................................... 50
Adding a RS232 Command to an Event ........................................................................ 51
Viewing RS232 Libraries................................................................................................ 52
Adding a New Device To a RS232 Library..................................................................... 53
Adding a New RS232 Function to a Device................................................................... 53
Copying RS232 Functions From an Existing Device to a New Device ........................... 54
Testing RS232 Functions ............................................................................................... 54
Creating a Test Serial Cable .......................................................................................... 54
Verifying RS232 Commands .......................................................................................... 54
IR Commands.......................................................................................................... 55
Opening IR Library Files ................................................................................................ 55
Adding an IR Command to an Event ............................................................................. 55
AMX IR Libraries ........................................................................................................... 56
Loading an Existing IR Library ....................................................................................... 56
Creating New IR Libraries ............................................................................................. 57
Importing AMX IR Library (IRL) Files ............................................................................. 57
Downloading IR Files From www.AMX.com.................................................................. 58
Creating New IR Libraries Using an IRIS IR/Serial Data Capture Device........................ 61
Importing IR HEX File Codes......................................................................................... 62
Using IR HEX Codes To Create New IR Libraries........................................................... 63
Testing IR Functions ...................................................................................................... 64
Input Port Scripts.................................................................................................... 65
Changing a Button Action....................................................................................... 65
Press.............................................................................................................................. 65
Release.......................................................................................................................... 65
Toggle........................................................................................................................... 65
Bank Assign................................................................................................................... 66
Novara ControlPads & KeyPads
iii
Table of Contents
Bank Enable................................................................................................................... 67
Using Bank Assign to Control Two Projectors - Example .............................................. 70
Advance Toggle ............................................................................................................ 73
Copy and Paste....................................................................................................... 74
Start Up .................................................................................................................. 74
Time Out................................................................................................................. 75
File Menu ................................................................................................................ 76
Run Mode ............................................................................................................... 76
Downloading the Program...................................................................................... 76
Downloading To an Auto-running panel........................................................................ 77
Adding a Relay Unit ................................................................................................ 77
NOVARA RS232 Codes .....................................................................................79
RS232 Protocol ....................................................................................................... 79
RS232 Press/Release Codes ................................................................................... 79
RS232 Function Codes ........................................................................................... 80
iv
Novara ControlPads & KeyPads

NOVARA ControlPads

Overview

NOVARA ControlPads offer the ability to easily control presentation devices such as projectors, projection screens, video displays and other audio visual equipment as well as a variety of serial or IR-controllable devices like lighting and window treatments.
NOVARA ControlPads are designed to be easily configurable allowing control of equipment by RS232 commands and IR.
The ControlPads are configured using the AMX NOVARA DCS1000 Device Configuration Software software application, available for download from www.amx.com. Refer to the AMX NOVARA DCS1000 Device Configuration Software section on page 43 for details.
NOVARA ControlPads
CP-1008-UK
CP-1008-US
CP-1016-TR-US
FIG. 1 NOVARA 1000 Series ControlPads
CP-1008-EU
CP-1016-TR-UK
The NOVARA 1000 Series of ControlPads include:
NOVARA 1000 Series ControlPads
Name Description Colors/FG#s
CP-1008-US
8-Button ControlPad
CP-1008-UK
8-Button ControlPad
CP-1008-EU
8-Button ControlPad
Fits 1-gang US conduit boxes.
Refer to the Minimum Internal Clearance for 1-Gang US Conduit Boxes section on page 4 for details.
Fits standard 2-gang UK conduit box sizes • White: FG1301-08-KW
Fits standard 2-gang European conduit box sizes • White: FG1301-08-EW
• White: FG1301-08-SW
• Black: FG1301-08-SB
• Brushed Aluminum: FG1301-08-SA
• Black: FG1301-08-KB
• Brushed Aluminum: FG1301-08-KA
• Black: FG1301-08-EB
• Brushed Aluminum: FG1301-08-EA
Novara ControlPads & KeyPads
1
NOVARA ControlPads

Product Specifications

NOVARA 1000 Series ControlPads (Cont.)
CP-1016-TR-US
16-Button ControlPad
CP-1016-TR-UK
16-Button ControlPad
Fits NEC-Compliant 3-gang US conduit boxes.
Refer to the Minimum Internal Clearance for 3-Gang US Conduit Boxes section on page 7 for details.
Fits standard 3-gang UK conduit box sizes. • White: FG1301-16-KW
• White: FG1301-16-SW
• Black: FG1301-16-SB
• Brushed Aluminum: FG1301-16-SA
• Black: FG1301-16-KB
• Brushed Aluminum: FG1301-16-KA
NOVARA 1000 Series ControlPads
Power Requirements: • Min: 250mA @ 12 VDC
• Max: 420mA @ 12 VDC (with all buttons illuminated to max brightness and 2 external devices attached to the RELAY 1/2 Ports in the ON state).
Button Layout: • 8 or 16 buttons
• Blue, backlit buttons with programmable feedback
Max number of events per ControlPad:
Rear Panel Connectors:
Top Panel Connector: 1 USB device configuration port.
Supported Baud Rates: 1200 - 115200
Dimensions (HWD): • CP-1008-US: 4.685" x 2.913" x 1.059" (11.899 cm x 7.399 cm x 2.689 cm)
Weight: • CP-1008-US: 0.30 lbs (136.08 g)
1330
RELAY 2 - Output port: can be used to control external devices (i.e. the AMX UPC-20+ Universal Power/Motor Controller - not included). This is a current sink (not a voltage driver). Max current sink - 100mA @12V.
SHARED 12V - Common +12V.
RELAY 1 - Output port: can be used to control external devices (i.e. the AMX UPC-20+ Universal Power/Motor Controller- not included). This is a current sink (not a voltage driver). Max current sink - 100mA @12V.
RS232 OUT - RS232 output port: supports one-way RS-232 control (TX only).
GND - Ground
IR OUT - Connects to an IR Emitter to support one-way IR control (TX only).
GND - Ground
INPUT - Input detection: connects to an external switch (such as a PIR switch), for detecting a High to Low or Low to High state.
-VE - Connects to the included 12V power supply (-).
+VE - Connects to the included 12V power supply (+).
• CP-1008-UK: 3.386" x 5.787" x 1.059" (8.600 cm x 14.698 cm x 2.689 cm)
• CP-1008-EU: 3.150" x 5.984" x 1.059" (8.001 cm x 15.199 cm x 2.689 cm)
• CP-1016-TR-US: 4.724" x 6.693" x 1.059" (11.998 cm x 17.000 cm x 2.689 cm)
• CP-1016-TR-UK: 4.331" x 9.055" x 1.059" (11.000 cm x 22.999 cm x 2.689 cm)
• CP-1016-TR-EU: 4.331" x 9.055" x 1.059" (11.000 cm x 22.999 cm x 2.689 cm)
• CP-1008-UK: 0.35 lbs (158.76 g)
• CP-1008-EU: 0.35 lbs (158.76 g)
• CP-1016-TR-US: 0.55 lbs (249.48 g)
• CP-1016-TR-UK: 0.65 lbs (294.84 g)
• CP-1016-TR-EU: 0.65 lbs (294.84 g)
2
Novara ControlPads & KeyPads
NOVARA ControlPads
NOVARA 1000 Series ControlPads (Cont.)
Included Accessories: • Button Kit - includes acetate sheet with 50 pre-cut button label inserts and clear
Other AMX Equipment: • 8 Button Kit (MA1301-01)
Certifications: • IEC 60950
plastic Key Caps
• w/ 8 Key Caps: MA1301-01
• w/ 16 Key Caps: MA1301-02
• Installation Kit - includes 8-pin captive wire connector and mounting screws (KA1301-01).
• External 12V Power Supply (57-1301-SA)
• 16 Button Kit (MA1301-02)
• FCC/CE
• RoHS compliant
Novara ControlPads & KeyPads
3
NOVARA ControlPads

Mounting Specifications - 8-Button ControlPads

US version NOVARA ControlPads are designed to fit in NEC-Compliant wall boxes only. These devices will not fit properly in non-NEC-Compliant wall boxes.

CP-1008-US

(4.701 cm)
(2.689 cm)
(7.399 cm)
(11.899 cm)
in inches - metric conversions
shown in parenthesis
FIG. 2 Mounting Specifications - CP-1008-US
(2.667 cm)
(6.799 cm)
(2.415 cm)

Minimum Internal Clearance for 1-Gang US Conduit Boxes

To ensure a proper fit with sufficient clearance, US-style NOVARA ControlPads require the following minimum internal dimensions within the conduit box:
US 1-Gang (HWD): 2.9” x 2.1” x 1.6” (7.36 cm x 5.33 cm x 4.06 cm)
These minimum interior dimensions will maintain a minimum .050” (1.27 cm)
4
Novara ControlPads & KeyPads

CP-1008-UK

NOVARA ControlPads
(6.799 cm)
(14.698 cm)
(8.600 cm)
in inches - metric conversions
shown in parenthesis
FIG. 3 Mounting Specifications - CP-1008-UK
(2.689 cm)
(2.667 cm)
(4.701)
(2.415 cm)
Novara ControlPads & KeyPads
5
NOVARA ControlPads

CP-1008-EU

(6.799 cm)
(2.689 cm)
(15.199 cm)
(2.667 cm)
(8.001 cm)
in inches - metric conversions
shown in parenthesis
FIG. 4 Mounting Specifications - CP-1008-EU
(4.701)
(2.415 cm)
6
Novara ControlPads & KeyPads
NOVARA ControlPads

Mounting Specifications - 16-Button ControlPads

US version NOVARA ControlPads are designed to fit in NEC-Compliant wall boxes only. These devices will not fit properly in non-NEC-Compliant wall boxes.

CP-1016-US

(13.599 cm)
(17.000 cm)
(11.998 cm)
in inches - metric conversions
shown in parenthesis
FIG. 5 Mounting Specifications - CP-1016-US
(2.689 cm)
(2.667 cm)
(6.799 cm)
(2.415 cm)

Minimum Internal Clearance for 3-Gang US Conduit Boxes

To ensure a proper fit with sufficient clearance, US-style NOVARA ControlPads require the following minimum internal dimensions within the conduit box:
US 3-Gang (HWD): 5.6” x 2.9” x 1.6” (14.22 cm x 5.33 cm x 4.06 cm)
These minimum interior dimensions will maintain a minimum .050” (1.27 cm)
Novara ControlPads & KeyPads
7
NOVARA ControlPads

CP-1016-UK/EU

(13.599 cm)
(22.999 cm)
(11.000 cm)
in inches - metric conversions
shown in parenthesis
FIG. 6 Mounting Specifications - CP-1016-UK/CP-1016-EU
(2.689 cm)
(2.667 cm)
(6.799 cm)
(2.415 cm)
8
Novara ControlPads & KeyPads
NOVARA ControlPads

Wiring and Connections

NOVARA ControlPads - Rear Panel Connectors

FIG. 7 shows the rear panel connectors of the NOVARA ControlPads, and indicates a typical installation:
SHARED 12V
Projector (RS232)
DVD Player (IR)
Power Supply
FIG. 7 NOVARA ControlPads - Rear Panel Connectors
The rear panel connector layout is identical for all NOVARA ControlPads.
Novara ControlPads & KeyPads
9
NOVARA ControlPads

Relay 1 / Relay 2 Connectors

The "Relay 1" and "Relay 2" Output ports each act as a switch to GND and are rated at 100 mA @ 12 VDC. These Output ports are used to control external devices (i.e. the PC1 Power Controller or AMX UPC-20+ Universal Power/Motor Controller - not included).
These Output ports do not function like "Relay" ports on other AMX equipment:
The Relay ports are for external relay control only.
FIG. 8 illustrates connecting the RELAY 1 (Output) Connectors to a PC1 Power Controller, in momentary/ latching mode.
The Relay 1 and Relay 2 output ports are current sinks, not voltage drivers, they switch the ports to
GND.
The "SHARED +12V" connector is common +12 VDC (not Ground).
These Output ports use 5V logic, but can handle up to 12V on the input without harm - at higher
voltages you run a higher risk of surge damage.
Control Wiring connector on PC1 (rear panel)
SHARED 12V
PC1 Pinouts
FIG. 8 Relay 1 / Relay 2 Connectors - Connected to PC1 Power Controller in momentary/latching mode
10
Novara ControlPads & KeyPads
NOVARA ControlPads

RS232 Out Connector

FIG. 9 illustrates connecting a 1000 Series ControlPad to RS232-controlled devices:
SHARED 12V
RS232 Device
Signal
GND
FIG. 9 RS232 Out Connector
NOVARA ControlPads support one-way RS-232 control (RS-232 TX signals to the third-party device, not RS-232 RX signals from the controlled device).

IR Out Connector

If using the CC-NIRC IR emitter with 2-pin phoenix connector (not included), be aware that the IR Emitter polarities on NOVARA ControlPads are opposite to that of other AMX equipment. This is not an issue if using the included 10-pin connector.
FIG. 10 illustrates connecting the IR transmitter heads to a 1000 Series ControlPad for IR-controlled devices:
SHARED 12V
IR Transmitter
FIG. 10 IR OUT Connector
The IR Transmitter must be placed directly in front of the controlled device’s IR window.
Signal
GND
Novara ControlPads & KeyPads
11
NOVARA ControlPads

Input Connector

FIG. 11 illustrates connecting the 1000 Series ControlPad to an external switch (such as a PIR switch), for detecting a High to Low or Low to High state.
FIG. 11 Input Connector
If for example a PIR is attached to the Input, this will act as a trigger to reset the internal inactivity timer for Time Out routines.
SHARED 12V
PIR Switch
GND
Input State

Power Supply Connector

If using an AMX Power Supply with 2-pin phoenix connector (not included), be aware that the Power Supply polarities on NOVARA ControlPads are opposite to that of other AMX equipment. This is not issue if using the included 10-pin connector.
FIG. 12 illustrates connecting the 1000 Series ControlPad to the included power supply.
SHARED 12V
Power Supply
FIG. 12 Power Supply Connector
Connect the White strip lead to the +VE terminal on the ControlPad,
Connect the Black strip lead to the –VE terminal.
When the ControlPad is powered up or a program downloaded, button #2 will flash for 2 seconds then extinguish to indicate that the ControlPad has passed it’s self-test.
12
Novara ControlPads & KeyPads
NOVARA ControlPads

USB Program Port

To download a program to the ControlPad, connect the USB Programming cable to the ControlPad USB Port on the top panel, and the USB Port of the PC (FIG. 13).
USB Program Port
8-Button ControlPads - top view
16-Button ControlPads - top view
FIG. 13 USB Program Port
NOVARA 1000 Series ControlPads are configured using AMX CP1000DCS software (available for download at www.amx.com).
Refer to the AMX NOVARA DCS1000 Device Configuration Software section on page 43 for configuration instructions.

Button Layout

FIG. 14 indicates the button layout for 8 and 16 button ControlPads:
2
1
3
4
5
6
7
8
1234
5678
8-button UK/EU style 16-button
8-button US style
FIG. 14 1000 Series ControlPads Button Layout
8-Button ControlPad buttons are always numbered 1 - 8 for configuration purposes.
16-Button ControlPads are always numbered 1 - 16.
1234
5678
15
13 14
16
12
9
10
11
Novara ControlPads & KeyPads
13
NOVARA ControlPads
14
Novara ControlPads & KeyPads

NOVARA AxLink KeyPads

Overview

NOVARA AxLink KeyPads can be used in both AxLink and Novara installations.
NOVARA AxLink KeyPads feature a 4-pin AxLink connector and Status LED.
NOVARA AxLink KeyPads feature one bi-directional RS-232 port, with accompanying loop-
through port.
8 and 16 button layouts are available. Each button has LED feedback.
NOVARA AxLink KeyPads
SP-08-AX-US
SP-08-AX-UK SP-08-AX-EU
FIG. 1 NOVARA AxLink KeyPads
NOVARA AxLink KeyPads include:
NOVARA AxLink KeyPads
Name Description Colors/FG#s
SP-08-AX-US
8-Button Keypad
SP-08-AX-UK
8-Button Keypad
SP-08-AX-EU
8-Button Keypad
SP-16-AX-TR-US
16-Button Keypad
SP-16-AX-TR-UK
16-Button Keypad
Fits 1-gang US conduit boxes.
See Mounting Specifications for details.
Fits standard 2-gang UK back box sizes. • Brushed Aluminum: FG1311-08-KA
Fits standard 2-gang European back box sizes.
Fits 3-gang US conduit boxes.
See Mounting Specifications for details.
Fits standard 3-gang UK back box sizes. • Brushed Aluminum: FG1311-16-KA
• Brushed Aluminum: FG1311-08-SA
• Black: FG1311-08-SB
• White: FG1311-08-SW
• Black: FG1311-08-KB
• White: FG1311-08-KW
• Brushed Aluminum: FG1311-08-EA
• Black: FG1311-08-EB
• White: FG1311-08-EW
• Brushed Aluminum: FG1311-16-SA
• Black: FG1311-16-SB
• White: FG1311-16-SW
• Black: FG1311-16-KB
• White: FG1311-16-KW
SP-16-AX-TR-US
SP-16-AX-TR-UK
Novara ControlPads & KeyPads
15
NOVARA AxLink KeyPads

Product Specifications

NOVARA AxLink KeyPads
Power Requirements: • SP-08: Min: 80mA / Max: 130mA @ 12 VDC
Button Layout: • 8 and 16 button
Rear Panel Connectors: • 4-pin AxLink connector/Status LED
RS232 Protocol: • Baud Rate: 9600
Dimensions: • SP-08-AX-US: 4.685" x 2.913" x 1.034" (11.899 cm x 7.399 cm x 2.626 cm)
Weight: • SP-08-AX-US: 0.30 lbs (136.08 g)
Included Accessories: • Button Kit - includes acetate sheet with 50 pre-cut button label inserts and clear
Other AMX Equipment: • 8 Button Kit (MA1301-01)
Certifications: • IEC 60950
• SP-16: Min: 100mA / Max: 210mA @ 12 VDC
• Blue, backlit buttons with controllable feedback
• RS-232 port, with accompanying loop-through port.
• Power connectors
•Data Bits: 8
• Stop Bits: 1
• Parity: No Parity
• SP-08-AX-UK: 3.386" x 5.787" x 1.034" (8.600 cm x 14.698 cm x 2.626 cm)
• SP-08-AX-EU: 3.150" x 5.984" x 1.034" (8.001 cm x 15.199 cm x 2.626 cm)
• SP-16-AX-TR-US: 4.724" x 6.693" x 1.037" (11.998 cm x 17.000 cm x 2.633 cm)
• SP-16-AX-TR-UK: 4.331" x 9.055" x 1.037" (11.000 cm x 22.999 cm x 2.633 cm)
• SP-08-AX-UK/EU: 0.35 lbs (158.76 g)
• SP-16-AX-TR-US: 0.55 lbs (249.48 g)
• SP-16-AX-TR-UK: 0.65 lbs (294.84 g)
plastic Key Caps
w/ 8 Key Caps: MA1301-01
w/ 16 Key Caps: MA1301-02
• Installation Kit - includes 6-pin captive wire connector and mounting screws (KA1310-01)
• 16 Button Kit (MA1301-02)
• External 12V Power Supply (57-1301-SA)
• FCC/CE
• RoHS compliant
16
Novara ControlPads & KeyPads
NOVARA AxLink KeyPads

Mounting Specifications - 8-Button KeyPads

NOVARA KeyPads are designed to fit in NEC-Compliant wall boxes only. These devices will not fit properly in non-NEC-Compliant wall boxes.

SP-08-AX-US

(4.701 cm)
(2.415 cm)
(2.702 cm)
(2.669 cm)
(11.899 cm)
in inches - metric conversions
shown in parenthesis
(2.956 cm)
(7.399 cm)
(6.799 cm)
FIG. 2 Mounting Specifications - SP-08-AX-US

Minimum Internal Clearance for 1-Gang US Conduit Boxes

To ensure a proper fit with sufficient clearance, US-style NOVARA ControlPads require the following minimum internal dimensions within the conduit box:
US 1-Gang (HWD): 2.9” x 2.1” x 1.6” (7.36 cm x 5.33 cm x 4.06 cm)
These minimum interior dimensions will maintain a minimum .050” (1.27 cm)
Novara ControlPads & KeyPads
17
NOVARA AxLink KeyPads

SP-08-AX-UK

(2.415 cm)
(6.799 cm)
(2.702 cm)
(2.669 cm)
(8.600 cm)
in inches - metric conversions
shown in parenthesis
FIG. 3 Mounting Specifications - SP-08-AX-UK
(2.956 cm)
(14.698 cm)
(4.701)
18
Novara ControlPads & KeyPads

SP-08-AX-EU

(2.415 cm)
NOVARA AxLink KeyPads
(6.799 cm)
(2.702 cm)
(2.669 cm)
(8.001 cm)
in inches - metric conversions
shown in parenthesis
FIG. 4 Mounting Specifications - SP-08-AX-EU
(2.956 cm)
(15.199 cm)
(4.701)
Novara ControlPads & KeyPads
19
NOVARA AxLink KeyPads

Mounting Specifications - 16-Button KeyPads

US version NOVARA KeyPads are designed to fit in NEC-Compliant wall boxes only. These devices will not fit properly in non-NEC-Compliant wall boxes.

SP-16-AX-TR-US

(13.599 cm)
(2.415 cm)
(2.669 cm)
(11.998 cm)
(17.000 cm)
(2.702 cm)
(2.956 cm)
(2.689 cm)
(2.669 cm)
(6.799 cm)
20
in inches - metric conversions
shown in parenthesis
FIG. 5 Mounting Specifications - SP-16-AX-TR-US
(2.415 cm)

Minimum Internal Clearance for 3-Gang US Conduit Boxes

To ensure a proper fit with sufficient clearance, US-style NOVARA ControlPads require the following minimum internal dimensions within the conduit box:
US 3-Gang (HWD): 5.6” x 2.9” x 1.6” (14.22 cm x 5.33 cm x 4.06 cm)
These minimum interior dimensions will maintain a minimum .050” (1.27 cm)
Novara ControlPads & KeyPads

SP-16-AX-TR-UK

(2.415 cm)
(2.669 cm)
NOVARA AxLink KeyPads
(13.599 cm)
(22.999 cm)
(11.000 cm)
in inches - metric conversions
shown in parenthesis
FIG. 6 Mounting Specifications - SP-16-AX-TR-UK
(2.702 cm)
(6.799 cm)
Novara ControlPads & KeyPads
21
Loading...
+ 61 hidden pages