AMX HPX-AV102-HDMI-R Quick Start Guide

QUICK START GUIDE
Retractable 5 foot (1.5 meter) HDMI MyTurn Ready cable connects to Source device
Cable Retract Push Button
Mounting notches (both sides)
5 ft. Cable Pigtail (1.5 meter) connects to Display device HDMI input
Pull trigger to initiate separation of the mounting collar from cartridge
Slide-hook and catch secures mounting collar to cartridge
Remove Pivot Pawl and Pivot Screw
Remove four remaining
sheet metal screws
(highlighted)
Remove top two screws (only on one-piece end cap models)
Warning Tape
4 Feet
1 Foot
Slow Pull
Pull
Trigger
Detachable
Mounting
cable cartridge
collar
DO NOT twist the detached cable cartridge. If a twist exists in the cable when remounted, the
Mounting
tongue
retractor will not fully
retrac t.
Slide the mounting notches on both sides of the mounting collar onto the mounting rails on both sides of the HPX Base
HPX Base Top Surface
Table cutout
Mounting Collar
HPX-AV102-HDMI-R

Overview

Hydraport Retractable Cable Modules are designed to be used in conjunction with the HPX-600/900/1200 or the Hydraport Touch (7”/10”) Connection Port base assembly, providing the convenience of multiple interfaces in a Hydraport System.
The HPX-AV102-HDMI-R HDMI 4K60 Module with Retractable MyTurn Ready Cable (FG552-32) is equipped with an HDMI cable for resolutions up to 4K @60Hz that mounts into the Hydraport base assembly (FIG. 1).
With the MyTurn™ Source Selection Button (FG554-21) optional accessory, participants can send their content to a display at the press of a button without moving from their seat. Any MyTurn-Ready cable may be equipped with the MyTurn solution. See “Optional MyTurn™ Source Selector Button” on page 2.
HDMI 4K60 Module with Retractable
MyTurn
The HPX-AV102-HDMI-R RCM cable cartridge mounts from underneath the table to sim plif y installat ion and up grade of ret ractable cable modules. This version RCM has a detachable mounting collar that is installed into the Hydraport base f irst and then the cable cartridge is attached to the mounting collar in the Hydraport base.
Securely holding the HPX-AV102-ETH-R RCM, extract enough cable to lay the cable cartridge on the floor while installing the mounting collar into the HPX Base Assembly (~3ft). When extracting 1.5 meter (4.9 ft) cable from the RCM, follow these simple steps:
4. Pull up to 1.5 meters of cable straight up ou t of the RCM and then lay it down.
5. Watch for red tape on the cable when extracting. It is a warning to slow pull for the final 1 foot to avoid damage to the RCM.
FIG. 3 EXTRACTING CABLE - WARNING TAPE
6. Pull the cable cartridge trigger (FIG. 4) to release the mounting collar tongue.
TM
Ready Cable
HPX-AV102-HDMI-R HDMI-R MODULE WITH RETRACTABLE CABLE
FIG. 1

Installation

Warning! - Do not attempt to open the retractable cable module enclosure. There are no serviceable parts inside the module.
- Opening the module enclosure may result in an uncontrolled release of spring forces which could cause serious injury and/or equipment damage.
- Opening the module enclosure will void the product warranty. Warning! - installation of the Hydraport in the table should ensure the pull-ou t length
of the cable can reach all potential users of connectivity, as excessively pulling on a fully extended cable can irreparably damage the retractor module.
Caution: Only use a hand-held #2 Phillips-head screwdriver for mounting this unit. Over­tightening the screws can hinder performance or damage the unit.
For existing HPX installations, the HPX base must be removed from the mounting surface. See “Existing Installations” on page 2 for HPX Base removal instructions.
1. Remove the (silver) pivot screw in the center of the End Cap (FIG. 2). There is an internal tooth washer underneath it. Keep them together for re-installation.
2. Remove the four (black) sheet metal screws that secure the two-piece End Cap to the HPX assembly (additional top two screws only on one-piece end cap models).
FIG. 2 HPX BASE ASSEMBLY - MOUNTING/PIVOT SCREW LOCATIO NS
3. Gently slide the End Cap out of the HPX base assembly.
FIG. 4 HPX-AV102-HDMI-R MOUNTING COLLAR REMOVAL
7. Lift the mounting collar away from the cable cartridge until the tongue is clear, and then slide to the side to clear the hook.
8. Feed the mounting collar up through the table cutout without twisting the cable, to reach the HPX base assembly. Align the mounting notches on the mounting collar with the mounting rails on the HPX base assembly (FIG. 5).
Note: Mounting collars are notched in a “tongue and groove" fashion to ensure that all modules are oriented correctly in the HPX. Note the orientation of the notched mounting collar on each module before sliding into the HPX assembly. On RCMs, ensure the retract buttons are all on the same side.
FIG. 5 RETRACTABLE CABLE MODULE - MOUNTING INTO AN HPX BASE ASSEMBLY
9. Slide the mounting collar into position.
10. Install any remaining module mounting collars into the HPX base.

Re-Install the End-Cap

Caution: Do not use a high-powered torque screw driver. Over-tightening these screws can damage the product.
1. Align the Mounting Notches on the End Cap with the Mounting Rails on the HPX base.
2. Slide the End Cap into the HPX base until it is fully inserted against the end of the base assembly. Watch out for the tension spring under the pivot pawl popping the pivot pawl off the end cap while pressing against the lid pivot point.
3. Secure the End Cap with the 4 to 6 (black) sheet metal screws (FIG. 2).
4. Replace the (silver) pivot screw and washer in the center of the End Cap.
93-0552-32 REV: B

Mount the HPX into the Mounting Surface

5 ft Cable Pigtail
HPX Base Assembly Top
Mounting Surface Top
Removable RCM cable cartridge mounted to
(285.3 mm)
11.2 inches maximum
(202.5 mm)
8 inches
Removable RCM mounting collar mounted to HPX
Base
mounting collar
Right retaining tab
(to secure the unit)
shown tightened
Left retaining tab
(to remove the unit)
shown loosened
Mounting Collar Pop-out panel
Slip cable through slot in panel
Notch in Collar used to pop out panel
Caution: Do not use a high-powered torque screw driver. Over-tightening these screws can damage the product.
Note: For detailed instructions on installing the HPX base assembly, refer to the HPX­600/900/1200 and HydraPort Touch (7”/10”) Installation Guides (available online at www.amx.com).
1. Carefully insert the HPX base into the cutout in the mounting surface.
2. Tighten the four mounting screws (FIG. 8) located inside and at each end of the HPX base assembly, to rotate the retaining tabs (FIG. 9) into locking position under the mounting surface.
3. Minding the twist in the cable, feed the excess cable up through the mounting collar and insert the cable cartridge hook into the mounting collar cutou t.
Note: If a twist in the cable occurs from rotating the cassette before insertion, the cable will bind and will not fully retract.
4. Push the cable cartridge trigger up onto the mounting collar tongue until it latc hes (oppos ite of FIG. 4).
5. Use the Push bu tton to retract the cable into the cartridge.
6. Attach the display ends of the cables as necessary and use cable ties to secure cable bundles as necessary.

Mounting Dimensions

FIG. 6 provides dimensions for the retractable cable module, when installed in an HPX­600/900/1200 and HPX-MSP-07/10 base assembly.

Existing Installations

For existing HPX installations, the HPX Base Assembly must be removed from the table surface before the Retractable Cable Modules can be installed:
Note: It may be necessary to reorient existing 1st generation RCMs in the chassis to ensure they fit against the non lip edge of MyTurn-Ready 2nd generation RCMs. Otherwise a 1/2 M blank panel (FG558-01) or other non retractable cable module needs to be installed between the 1st Generation and MyTurn-Ready 2nd Generation RCMs.
1. Cu t/remove any cable ties that would restrict the removal of the HPX Base Assembly.
2. Loosen four mounting screws inside and at each end of the HPX base assembly (FIG. 8), in order to rotate the retaining tabs from under the mounting surface.
Note: When the cover of the HPX base is open, only two of these screws are visible. To access the other two screws, tip the cover over to the opposite open position.
FIG. 8 HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
3. Once the retaining tabs have been rotated out from under the mounting surface, the HPX assembly can be lifted away from the mounting surface.
FIG. 9 provides a cutaway view of the End Cap, showing the retaining tabs highlighted in both the loose position and the tightened (secure) position.
RCM MODULE (INSTALLED IN AN HPX BASE ) - DET AILED DIMEN SIO NS
FIG. 6

Optional MyTurn™ Source Selector Button

For customers who purchase the optional HPA-MYT-TX MyTurn™ Source Selector Button (FG554-21), it clips into the specially designed groove built into the end of a MyTurn ready cable. Users press the button to send content on their device to the display. When pressed, the button transmits a signal to an optional receiver (FG554-23) that plugs directly into an AMX switching device, such as a Solecis SDX, Enova DVX, or NX Series Controller.
MyTurn Source Selector Buttons are illuminated briefly when that specific device is selected, making it easy to determine whose content is being shown on the display at any given time. Refer to the HPA-MYT-TX documentation available at www.amx.com for more details.
FIG. 7 OPTIONAL MYTURN™ SOURCE SELECTION BUTTON (FG554-21)
Last Revised: 9/21/2016
© 2016 Harman. All rights reserved. Hydraport, AMX, AV FOR AN IT WORLD, HARMAN, and their respective logos are registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior no tice at any time. The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153 AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
FIG. 9 HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
4. Return to the installation section at the bo ttom left column o f page 1 to continu e with installing the RCM into the HPX Base assembly.

Replacing MyTurn Ready RCMs

Removal of the HPX Base assembly is not required to replace this RCM:
1. Detach the cable cartridge from the mounting collar (FIG. 4).
2. From the top of the mounting collar, press a small flat blade screwdriver into the notch on the split side of the pop out panel and pop it out of place (FIG. 10)..
FIG. 10 RCM MOUNTING COLLAR POP-OUT PANEL
3. Slip the cable out through the mounting collar.
4. Replace with new RCM in reverse order ensuring the cable is not twisted and the pop out panel split is oriented towards the notch in the collar.

Additional Documentation

Refer to the Products > Architectural Connectivity catalog page on www.amx.com (Dealer Site) for additi ona l produc t docume ntatio n.