AMX CB-MVPWDS User Manual

Installation Guide
CB-MVPWDS Rough-In Box for MVP-WDS Wall Docking Station

Overview

The CB-MVPWDS Rough-In Box allows the MVP-WDS to be installed in a solid surface (e.g., wall or podium). This Rough-In box includes a removable access plate to provide better access to wiring. The CB-MVPWDS is symmetric top-to­bottom, so the access plate may be installed at the top or the bottom.

Specifications

CB-MVPWDS (FG037-10) Specifications
Dimensions (HWD): • 8 3/16" x 12" x 3 1/4"
• 20.7 mm x 30.4 mm x 8.2 mm
Included Accessories • Five mountings screws (#4-24 X .188, PFH, BLK,
Certifications: • cTUVus Listed
WARNING: INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK. This gap allows the installation of the drywall/sheetrock after the CB-MVPWDS has been mounted onto the beams. The stud notching and Rough-In Box installation must be done prior to any wall installation.
Note: The most important thing to remember when mounting this Rough-In Box is that the mounting tabs must be mounted flush against the outside of the sheetrock. This step determines whether or not the mounting stud is notched
(cutout-out to fit the Rough-In Box).
TYPE B, SELF-TAPPING, SHT MTL) (80-0203-01)

Installing the CB-MVPWDS Rough-In Box

The CB-MVPWDS (FG037-10) is a metallic Rough-In Box that can be secured to a stud in a pre-wall setting. The MVP-WDS can then installed into the Rough-In Box.
Note: Installation procedures and configurations vary depending on the installation environment.
When mounting the Rough-In Box, the MVP-WDS Mounting Tabs must lie flush against the outside of the sheetrock.
Refer to SP596502 for detailed installation dimensions (see reverse).
• It is recommended that you cut out the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.
• The CB-MVPWDS can be installed with the removable access panel positioned either on top or bottom. The access panel provides convenient access to in-wall wiring and must be re-installed prior to mounting the MVP-WDS.
1. Place the left side of the Rough-In Box on a stud, making sure that five Stud Fastening Holes and removable Access Panel are oriented correctly (installation dependent). Be sure to leave enough of a gap between the stud and Mounting Tabs to accommodate the installation of the drywall or sheetrock after the Rough-In Box has been mounted. Ultimately, the Mounting Tabs should lie flush against the outside of the sheetrock.
Note: Although there are wiring knockouts are on both sides of the Rough-In Box, the knockouts on the right side will be used for the MVP-WDS (wall docking station) connectors, so always secure the Rough-In Box to the stud using the Stud Mounting Holes on the left side of the box.
2. Using either nails or screws, fasten the Rough-In Box to the stud through the five Stud Fastening Holes.
3. Remove the wiring knockouts from the right side of the Rough-In Box to accommodate cabling to the MVP-WDS.
4. Thread the USB and Power cables through the knockouts on the right of the Rough-In Box. It is recommended that you test these connections before fully installing the WDS.
5. Install the drywall/sheetrock before inserting the MVP-WDS into the Rough-In Box.
Stud Fastening Holes
(5 located on left panel)
Drywall or sheetrock
Stud
Removable Access Panel
Wiring knockouts
MVP-WDS mounting tabs
(should lie flush against the
outside of the wall)
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
AMX reserves the right to alter specifications without notice at any time.