AMX AXF-S User Manual

Reference Guide
AXC-S CardFrame Server Card

Overview

The AXC-S CardFrame Server Card (FIG. 1) is a processor card that manages communication among control cards in a CardFrame. This card is included in both a Master (AXF-M/S) and Server (AXF-S) CardFrame.
This card is essential to convert AXlink signals and communicate backplane signals to the other AXC cards present in a CardFrame.
One time programmable chip (OTP)
FIG. 1
AXC-S Server Card (side view)
P2 AXLink connector
S1 DIP switch
Handling grip
AXC-S Specifications
Power 30 mA @ 12 VDC
Processor Motorola MC68HC705
Mounting Inserts into the CS slot in an Axcess CardFrame
Program Chip Onboard OTP (One Time Programmable) chip
LED Indicators • CR1 (AXlink) indicates transmission of data
AXLink Connector • Front connector used for AXlink communication.
• Full On - indicates no communication with master
• Full Off - indicates no power being received by unit
• One blink/second - indicates normal operation
• Also used for daisy-chaining several CardFrames together.

Installation

1. Locate the CS (Card Server) slot on the front of the Axcess CardFrame.
2. Grasp the card from the handling grip location.
3. Slide the AXC-S card into the CardFrame until the rear connectors “snap” into place.
4. Verify a secure connection to the rear of the unit.
5. Apply power to the CardFrame and verify a “one-blink” pattern on the AXlink LED (CR1). Refer to the CR1 Specifications for more information on blink patterns.

Setting the AXlink Device DIP switch (S5)

The eight-position Device DIP switch (S1), shown in FIG. 2 assigns the value to the CardFrame using the AXC-S card. The Device DIP switch example is set to 1, the factory default setting.
AXlink DIP switch (S1)
1 2 3 4 5 6 7 8
FIG. 2 DIP switch (S1)
The AXlink device number range is 1-255. The Device DIP switch positions determines their values, based on the following table.
Device DIP Switch (S1) Settings and Values
Position
Val ue
The dip switch sets the first address of the card frame with the other 15 slots following in order.
For example: if set to one, the card frame addresses are set from 1 to 16. If set to two, the card frame addresses are set from 2 to 17.
The highest number allowable on the dip switch is 240 which would make the last device address 255.
12 34567 8
1 2 4 8 16 32 64 128
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993