AMX AXC-REL14 User Manual

Product Information

Devices that require a simple momentary or latching contact closure can be controlled with the AXC-REL14 Universal Fourteen Relay Card. This card operates up to 14 relay-controlled functions in a dual 7 relay configuration. Each section of seven relays on the AXC-REL14 are commoned and both sections may be commoned together.
The following table lists the AXC-REL14 specifications.
Specifications
Power Requirements 150 mA @ 12 VDC
Relay Contact Rating 1/2 A @ 24 VAC / 28 VDC.
Jumpers CO1 - 8: On common Relays 1 - 7 with Relays 8 - 14
Contact Closures 14 per card; normally open contacts
LEDs Two rows of 7 LEDs (CR1 - CR14)
Commons 7 and 8 can be connected together via a jumper on the
card, thereby commoning all relays.

Connections

The following table lists the pinouts for the AXC-REL14.
Connector Pinouts
Pinout Description
1 Common 1 - 7
2 Contact #1
3 Contact #2
4 Contact #3
5 Contact #4
6 Contact #5
7 Contact #6
8 Contact #7
9 Contact #8
10 Contact #9
11 Contact #10
12 Contact #11
13 Contact #12
14 Contact #13
15 Contact #14
16 Common 8 - 14
Quick Start Guide
AXC-REL14 Universal Fourteen Relay Card
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
031-023-2510 5/04 ©2004 AMX Corporation. All rights reserved. The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993
notice at any time.