Installation Guide
NOVARA 1000 Series ControlPads
Overview
NOVARA 1000 Series ControlPads (FIG. 1) offer simplified device control with just the
right mix of ease of use, simplicity of configuration, and cost effectiveness. NOVARA
ControlPads are designed to be easily configurable allowing control of equipment by
RS232 commands and IR.
The ControlPads are configured using the NOVARA DCS1000 (Device Configuration
Software) software application, available for download from www.amx.com. Refer to
the NOVARA ControlPads & KeyPads Operation/Reference Guide (available at
www.amx.com) for configuration instructions.
CP-1008-US
CP-1008-UK
CP-1008-EU
NOVARA 1000 Series ControlPads
FIG. 1
The NOVARA 1000 Series of ControlPads include:
NOVARA 1000 Series ControlPads
Name Description Colors/FG#s
CP-1008-US
8-Button
ControlPad
CP-1008-UK
8-Button
ControlPad
CP-1008-EU
8-Button
ControlPad
CP-1016-TR-US
16-Button
ControlPad
CP-1016-TR-UK
16-Button
ControlPad
Fits 1-gang US conduit
boxes.
See Mounting
Specifications for details.
Fits standard 2-gang
UK conduit box sizes.
Fits standard 2-gang
European conduit box
sizes.
Fits 3-gang US conduit
boxes
See Mounting
Specifications for details.
Fits standard 3-gang UK
conduit box sizes.
Product Specifications
NOVARA 1000 Series ControlPads
Power Requirements: • Min: 250mA @ 12 VDC
Button Layout: • 8 or 16 buttons
Max number of events
per ControlPad:
Rear Panel
Connectors:
• Max: 420mA @ 12 VDC (with all buttons illuminated to
max brightness and 2 external devices attached to the
RELAY 1/2 Ports in the ON state).
• Blue, backlit buttons with programmable feedback
1330
• RELAY 2 - Output port: can be used to control external
devices (i.e. the AMX UPC-20+ Universal Power/Motor
Controller - not included). This is a current sink (not a
voltage driver). Max current sink - 100mA @12V.
• SHARED 12V - Common +12V.
• RELAY 1 - Output port: can be used to control external
devices (i.e. the AMX UPC-20+ Universal Power/Motor
Controller- not included). This is a current sink (not a
voltage driver). Max current sink - 100mA @12V.
• RS232 OUT - RS232 output port: supports one-way
RS-232 control (TX only).
• GND - Ground
CP-1016-TR-US
CP-1016-TR-UK
• White: FG1301-08-SW
• Black: FG1301-08-SB
• Brushed Aluminum: FG1301-08-SA
• White: FG1301-08-KW
• Black: FG1301-08-KB
• Brushed Aluminum: FG1301-08-KA
• White: FG1301-08-EW
• Black: FG1301-08-EB
• Brushed Aluminum: FG1301-08-EA
• White: FG1301-16-SW
• Black: FG1301-16-SB
• Brushed Aluminum: FG1301-16-SA
• White: FG1301-16-KW
• Black: FG1301-16-KB
• Brushed Aluminum: FG1301-16-KA
NOVARA 1000 Series ControlPads (Cont.)
Rear Panel
Connectors (Cont.):
Top Panel Connector: 1 USB device configuration port.
Supported Baud
Rates:
Dimensions (HWD): • CP-1008-US: 4.685" x 2.913" x 1.059"
Weight: • CP-1008-US: 0.30 lbs (136.08 g)
Included Accessories: • Button Kit - includes acetate sheet with 50 pre-cut
Other AMX Equipment: • 8 Button Kit (MA1301-01)
Certifications: • IEC 60950
• IR OUT - Connects to an IR Emitter to support one-way
IR control (TX only).
• GND - Ground
• INPUT - Input detection: connects to an external switch
(such as a PIR switch), for detecting a High to Low or
Low to High state.
• -VE - Connects to the included 12V power supply (-).
• +VE - Connects to the included 12V power supply (+).
1200 - 115200
(11.899 cm x 7.399 cm x 2.689 cm)
• CP-1008-UK: 3.386" x 5.787" x 1.059"
(8.600 cm x 14.698 cm x 2.689 cm)
• CP-1008-EU: 3.150" x 5.984" x 1.059"
(8.001 cm x 15.199 cm x 2.689 cm)
• CP-1016-TR-US: 4.724" x 6.693" x 1.059"
(11.998 cm x 17.000 cm x 2.689 cm)
• CP-1016-TR-UK: 4.331" x 9.055" x 1.059"
(11.000 cm x 22.999 cm x 2.689 cm)
• CP-1008-UK: 0.35 lbs (158.76 g)
• CP-1008-EU: 0.35 lbs (158.76 g)
• CP-1016-TR-US: 0.55 lbs (249.48 g)
• CP-1016-TR-UK: 0.65 lbs (294.84 g)
button label inserts and clear plastic Key Caps
w/ 8 Key Caps: MA1301-01
w/ 16 Key Caps: MA1301-02
• Installation Kit - includes 8-pin captive wire connector
and mounting screws (KA1301-01)
• External 12V Power Supply (57-1301-SA)
• 16 Button Kit (MA1301-02)
• FCC/CE
• RoHS compliant
Mounting Specifications
Refer to the Product Specifications table above for dimensions. Dimensional drawings
are available in the NOVARA ControlPads & KeyPads Operation/Reference Guide.
Minimum Internal Clearance for US Conduit Boxes
To ensure a proper fit with sufficient clearance, US-style NOVARA ControlPads require
the following minimum internal dimensions within the conduit box:
• US 1-Gang (HWD): 2.9” x 2.1” x 1.6” (7.36 cm x 5.33 cm x 4.06 cm)
• US 3-Gang (HWD): 2.9” x 5.6” x 1.6” (14.22 cm x 5.33 cm x 4.06 cm)
These minimum interior dimensions will maintain a minimum .050” (1.27 cm)
clearance around the NOVARA unit.
Wiring and Connections
ControlPads - Rear Panel Connectors
FIG. 2 shows the rear panel connectors of the NOVARA ControlPads:
Relay 2
+12 VDC+12 VDC
SHARED 12V
RS232 Device
Relay 1
Signal
Installing Acetate Button Labels and Key Caps - READ THIS FIRST!
1. Punch out the desired Button Label from the included acetate sheet.
If you have printed your own custom button labels on acetate, cut each button
label to fit inside the Key Caps.
• Custom button labels must be cut to a 1.20cm (0.472") square to fit securely
inside the Key Caps.
• The thickness of the acetate used must not exceed .004” (0.10 mm).
2. Place the Key Cap face-down, and insert the Button Label into the bottom of
the Key Cap (FIG. 4).
Acetate Button Label
(face down)
Clip
GND
Signal
IR Transmitter
PIR Switch
GND
GND
Input State
NOVARA ControlPads - Rear Panel Connectors
FIG. 2
Power Supply
Notes on “Relay 1/2” Connectors
The "Relay 1" and "Relay 2" Output ports each act as a switch to GND and are rated
at 100 mA @ 12 VDC. These Output ports are used to control external devices (i.e.
the PC1 Power Controller or AMX UPC-20+ Universal Power/Motor Controller - not
included).
These Output ports do not function like "Relay" ports on other AMX equipment:
• The Relay 1 and Relay 2 output ports are current sinks, not voltage drivers,
they switch the ports to GND.
• The "SHARED +12V" connector is common +12 VDC (not Ground).
• These Output ports use 5V logic, but can handle up to 12V on the input without
harm - at higher voltages you run a higher risk of surge damage.
Note: The Relay ports are for external relay control only.
Connecting the Power Supply
• Connect the White strip lead to the +VE terminal on the ControlPad,
• Connect the Black strip lead to the –VE terminal.
Note: If using an AMX Power Supply other than the one supplied, be aware that the
Power Supply polarities on Novara ControlPads are opposite to that of other AMX
equipment. This is not issue if using the included power supply.
When the ControlPad is powered up or a program downloaded, button #2 will flash
for 2 seconds then extinguish to indicate that the ControlPad has passed it’s
self-test.
USB Program Port
To download a program to the ControlPad, connect the USB Programming cable to
the ControlPad USB Port on the top panel, and the USB Port of the PC (FIG. 3).
Clip
Key Cap (face-down)
FIG. 4 Placing a Button Label inside a Key Cap
• Orient the Button Label inside the Key Cap so that the two clips are located on
the left and right sides of the readable text on the Button Label, as indicated in
FIG. 4.
• Be sure to place the Button Label face-down inside the Key Cap (see FIG. 4),
otherwise the label will be seen in reverse once the Key Cap is installed.
3. Install the Key Cap on the pushbutton (FIG. 5):
Key Cap - tilted so that the bottom
of the Cap is placed on the bottom
Press the top of the Key Cap
down to engage both clips at
once, securing the Key Cap
of the pushbutton first
Clip
Pushbutton on keypad
to the pushbutton
At this point, do not allow the clips
on the sides of the Key Cap to engage
1
Clip
2
USB Program
Port
8-Button ControlPads - top view
16-Button ControlPads - top view
FIG. 3 USB Program Port
NOVARA 1000 Series ControlPads are configured using the NOVARA DCS1000
Device software application (available for download at www.amx.com).
Button Labelling
NOVARA ControlPads come with a set of clear plastic Key Caps, which are designed
to fit tightly over the pushbuttons, and allow you to place a label on each button
according to the requirements of your particular installation.
NOVARA ControlPads also come with a pre-printed acetate sheet with a range of 50
(pre-cut) button label inserts. The button labels provided will accommodate most
installations, but it is also possible to print your own button labels on acetate for
custom button labelling.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
AMX reserves the right to alter specifications without notice at any time.
9/08
Once the clips are engaged,
the Key Cap is secured
to the pushbutton
3
FIG. 5 Placing a Button Label inside a Key Cap
Note: Verify that the vertical orientation of the Button Label is correct relative to the
keypad.
a. Gently press the bottom of the Key Cap (no clip) onto the pushbutton.
Do not allow the clips on either side to engage.
b. With the bottom of the Key Cap secured, gently press the top of the Key
Cap. This action will engage both clips simultaneously, and the Key Cap
will snap into place on the push button.
Note: Be careful to follow these procedures closely - the bottom of the Key Cap must
be installed on the pushbutton before the Key Cap clips engage, or there is a risk of
the button being misaligned.
Removing the Key Caps requires additional steps - refer to the NOVARA
ControlPads & KeyPads Operation/Reference Guide for details on Replacing Button
Labels/Key Caps.
Additional Documentation
Refer to the NOVARA ControlPads & KeyPads Operation/Reference Guide
(available at www.amx.com) for additional installation/wiring details, instructions on
using the NOVARA DCS1000 software application to configure the devices, and
RS232 control instructions.
93-1301-01 REV: D