-------------------------------------Upgrade Studio 1.7 Readme
February 2020
--------------------------------------
Contents
========
1. New features
2. Upgrade Studio
3. Discrepancies
4. Technical support
5. Information on Trex applications
---------------
1. New features
--------------Upgrade Studio 1.7 adds support for the following:
- File transfer capability formerly in the Trex File Transfer Utility has now been
incorporated into the Upgrade Studio application
- The ability to download a PDF file to the Trex unit for viewing on the Trex has
been added to Upgrade Studio.
- The Trex Remote Viewer application is now installed with Upgrade Studio.
-----------------
2. Upgrade Studio
----------------Install the latest version of Upgrade Studio (1.7) before connecting a Trex unit.
Installation requirements
-------------------------
Windows 10 Professional or greater editions
Windows 10 IoT, Enterprise or greater editions
Windows Server 2012 R2 Standard or greater editions
Windows Server 2016 Standard or greater editions
- Only 64-bit versions of the operating systems are supported
- 512 MB of free disk space
- A Windows user account with Administrator privileges
Upgrade Studio can be co-deployed with AMS Device Manager 13.5, 14.0, and 14.1.1 as
long as those versions have been updated to the latest hot fixes.
If you want to upgrade a co-deployed AMS Device Manager 13.5 or 14.0 and Upgrade
Studio 1.7 system to AMS Device Manager 14.1.1, contact Technical Support.
You must restart your PC after installing Upgrade Studio on an AMS Device Manager
station.
Using Upgrade Studio
--------------------

When you use Upgrade Studio, ensure a USB port is available on the PC for
transferring and installing updates onto the Trex unit.
Also, an internet connection is required to download updates.
However, you can use Upgrade Studio without an internet connection. See the Help
within Upgrade Studio (More > Help) for more information.
When downloading AMS Trex components, always download and install all OS components
available.
When using Upgrade Studio 1.7 on an AMS Device Manager 13.5, 14.0, or 14.1.1
station, make sure to install all updates for Trex units.
AMS Trex communicates with wireless networks at port 8009. If your network uses this
port or restricts access to it, AMS Trex may not be able to communicate with the
network. To change port settings on the AMS Trex unit, enter the port number on
Settings > Platform Communications. Emerson recommends setting all AMS Trex units to
exchange data on that
port.
In AMS Device Manager, all AMS Device Manager stations that synchronize with AMS
Trex units must also have the same port number. To change the port settings:
1. Open PlatformCommunications.PC.exe.config on Notepad from the
either of the following locations:
- Windows 64-bit: C:\Program Files (x86)\Emerson Process
Management\PlatformCommunications
- Windows 32-bit: C:\Program Files\Emerson Process
Management\PlatformCommunications
2. Change the port number for the value field:
<add key="0005D4DF-695D-0777-BD0D967C4D8B6976\Platform\ExchangePort"
value="8009"/>
3. Restart the PC.
Configuration Management Application
-----------------------------------When you install Upgrade Studio, the Configuration Management Application is also
installed. This application lets you transfer HART configurations to and from Trex
units, and manage and print those configurations.
Trex File Transfer Utility
-------------------------When you install Upgrade Studio, the Trex File Transfer Utility is also installed.
This utility lets you transfer datasets from the ValveLink Mobile application, log
files from the Fieldbus Diagnostics application, and historical data from the Radar
Master application from the Trex unit to a PC.
----------------
3. Discrepancies
----------------