Data Sheet
VPC-31
Voltage & Continuity Tester
Rugged and easy to use testers for live voltage and continuity
checks. Built in shaker provides the same functionality and feel as
older analog solenoid testers with benefit of full input protection
to CAT IV 600V / CAT III 1000V.
n Super-bright bi-Color LED’s indicates safe and dangerous
voltages (above 55VDC or 30VAC)
n Auto hold feature - LED’s stay illuminated for 10 sec retaining
a reading after the tests are disconnected
n Solenoid tester-like shaker to indicate AC voltage presence
n Automatically turns ON and OFF for easy and quick
measurements
n Non-contact voltage detection and GFCI test feature for
testing GFCI receptacles and breakers
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
“No Hassle” warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
n Standard detachable test lead (black) for easy replacement
with optional longer or specialized probe
n Automatically selects AC Voltage, DC Voltage or Continuity
n LED’s indicate 10 levels of AC and DC Voltages::
n Volts (AC) 24, 48, 120, 208, 240, 277, 347, 480, 600, 1000
n Volts (DC) 6, 12, 24, 36, 48, 60, 72, 110, 220, 380
n Auto backlit LCD Digital Display for precise voltage
measurements
n
Continuity buzzer and Visual continuity indication (LED)
n Water and dust proof, IP65 design
n Safety CAT IV 600 V, CAT III 1000 V
Amprobe® Test Tools
www.Amprobe.com
VPC-31 Voltage & Continuity Tester
Data Sheet
Specifications
LCD Display 3 digits 1000 counts
In an RF Field of 3V/m, total accuracy = Specified accuracy + 45d. Performance above 3V/m is not
specified
Update Rate 5 per second nominal
Operating Temperature -10ºC ~ 55ºC (14ºF ~ 131ºF)
Relative Humidity Maximum relative humidity 80% for temperature up to 31ºC (87ºF) decreasing linearly to 50%
relative humidity at 55ºC (131ºF)
Altitude Operating below 2000m
Storage Temperature -20ºC ~60ºC (-4ºF ~ 140ºF), < 80% R.H. (with battery removed)
Temperature C oefficient Nominal 0.15 x (specified accuracy)/ ºC @ (-10ºC ~ 18ºC or 28ºC ~ 55ºC), or otherwise specified
Sensing Average sensing
Type of Protection IP65
Pollution Degree 2
E.M.C. Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000 -4 -8, EN61000-4-11): For both models:
Performance is specified in an RF Field of 3V/m. Performance above 3V/m is not specified.
Safety Meets EN61010-1 and IEC61010-1 2nd Edition (2001)
Measurement Category CAT III 1000V & CAT IV 600V AC & DC
Transient Protection 8kV lightning surge (1.2/50µs)
Overload Protection 1000VDC & VAC rms
Low Battery Below approx. 2.4V
Power Supply Standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03)
alkaline battery X 2
Power Consumption (typical) 3mA at Power-on ready; 30mA at 1000VAC full LED indication. 75mA at 1000VAC with shaker ON
APO Consumption (typical) 10
APO Timing Idle for 30 seconds
Dimension 233(L) x 57(W) x 40(H)mm (9.17 x 2.24 x 1.57 in)
Weight Approx. 220 g (0.485 lb)
Special Features High Input Impedance, Indicator Self-Test, Auto-Hold, Overload-Alert Warning, EF-Detection,
Auto Display Backlit, AC-Detection Shaker, Bi-Color LED Hazardous Live Warning, and GFCI Leakage
Load
Accessories Detachable (Black) Test Lead, Screw-on Stationary (Red) Probe, 2 Screw-on 4mm Probe Tips,
batteries installed and User’s manual
µA
Amprobe® Test Tools
www.Amprobe.com