Thermocouple Thermometer K Type
Users Manual
June 2010, Rev.1 ©2010 Amprobe Test Tools. All rights reserved. Printed in Taiwan
English
Page 4
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES ­WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Repair
All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe® Test Tools distributor for an exchange for the same or like product. Please check the “Where to Buy” section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe® Test Tools Service Center (see address below).
Page 5
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire at your point of purchase for current repair and replacement rates.
In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test Tools distributor for a nominalv charge. Please check the “Where to Buy” section on www.amprobe.com for a list of distributors near you. European Correspondence Address*
Amprobe® Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 *(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
Page 6
TMD-50 Thermocouple Thermometer K Type
11
10
2
1
4
7
3 5 6 8 9
1) “
” Power Button
2) °C /°F Button
3) “
” Button
4) “ADJ” Button
5) “p/REL” Button
6) “q/HOLD” Button
7) “T1 T2/T1-T2” Button
8) “MAX/MIN” Button
9) “>2S APO/ENTER” Button
10) LCD Display
11) T1/T2 Input
Page 7
Screen Display
4 3
2
1) Temperature display
2) Low BATT display
3) K type of T/C thermocouple
4) Auto power off
5) MAX/MIN reading
5
1
6
6) Relative mode
7) Data HOLD mode
8) Degrees °C /°F
9) T1/T2 thermocouple or T1-T2 differential
7
8
9
Page 8
CONTENTS
SYMBOLS ............................................................................ 2
UNPACKING AND INSPECTION .......................................... 2
INTRODUCTION .................................................................. 3
Features ..........................................................................3
OPERATION INSTRUCTIONS ...............................................3
“ Power Button ......................................................... 3
°C/°F” Selecting the Temperature Scale ..................... 3
” Button: Display Back-Light ................................... 3
ADJ” Button: Adjust thermocouple offset ................. 4
p/REL” Button ............................................................. 4
q/HOLD” Button ......................................................... 4
T1 T2/T1-T2” Button ....................................................4
MAX/MIN” Button ....................................................... 5
>2S APO/ENTER” Button ............................................. 5
SPECIFICATION .................................................................... 5
MAINTENANCE ................................................................... 7
1
Page 9
SYMBOLS
Caution! Refer to the explanation in this Manual
Conforms to relevant Australian standards
Complies with European Directives
Tested Comply With FCC Standards
Do not dispose of this clamp meter as unsorted
municipal waste.
WARNING and PRECAUTIONS
• To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC.
• To avoid damage or burns, do not make temperature measurement in microwave ovens.
• Repeated sharp exing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector.
UNPACKING AND INSPECTION
Your shipping carton should include:
1 TMD-50 meter
1 Manual
2 K type Thermocouple
4 AAA Batteries
1 Plain white box
If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange.
2
Page 10
INTRODUCTION
There are 2 sets of sockets for thermocouple plugs at the top of instrument marked with T1 and T2.
Features
• Highly accurate dual input thermometer with 0.1%
basic accuracy.
• Dual input T1, T2, T1-T2.
• Thermocouple offset adjust.
• Large display for easy to read.
• Robust protective Holster.
• Auto-Power Off.
• Display back-light.
• MIN/MAX/AVG/REL/HOLD functions.
• Wide measuring ranges for versatile applications
OPERATING INSTRUCTIONS
“ ” Power Button
Press the “ ” key to turn on or off thermometer. In the
MAX/MIN record mode can not power off, must leave MAX/MIN record mode then power off.
“ °C/°F ” Selecting the Temperature Scale
Reading are displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the “°C/°F” key.
“ ” Button: Display Back-Light
Press the key to turn on the Back-Light. Press the “ ” key again to make the Back-Light lighter and press “ ”
3
Page 11
key once more to cancel the Back-Light function. Back-Light on
g lighter g Back-Light off
“ADJ” Button: Adjust thermocouple offset
1. Insert the bead wire into a known temperature (T) until the display equal to known temperature (T). exp: ice point at 0°C boiling water at 100°C (Press “ADJ” key).
2. Press “p” or “q” to add or subtract the value.
3. It can be adjusted ±6°C (±10.8°F) of default. If you
can’t adjust your T/C, please check your T/C or send
the meter to be calibrated.
4. Press “ENTER” key to confirm.
p/REL” Button
Press “REL” key to enter Relative mode, zero the display, and store the displayed reading as a reference value and annunciator REL is displayed. Pressing “REL” key over 2 seconds to exit the relative mode.
q/HOLD” Button
Press the “HOLD” key to enter the Data Hold mode, the “HOLD” annunciator is displayed at the higher center of display. When HOLD mode is selected, the thermometer held the present readings and stops all further Measurements. Press the “HOLD” key again cancels HOLD mode, causing thermometer to resume taking measurements.
“T1 T2/T1-T2” Button
Press “T1”, “T2”, “T1-T2” key to select input mode T1, T2 or T1-T2. The input selection indicates which input is selected for display. T1 thermocouple, T2 thermocouple or the differential between the two thermocouples(T1-T2), when the thermocouple is turned on, it is set to T1.
4
Page 12
“MAX/MIN” Button
Press “MAX/MIN” key to enter the MIN MAX recording mode. (Displays the Maximum reading, Minimum reading, “MAX-MIN”, “AVG” reading stored in record mode). Press “MAX/MIN” key to cycle through the MAX, MIN, MAX-MIN, “AVG” readings. In this mode, press “HOLD” key to stop recording, all values are frozen, press again to restart recording.
In this mode, the APO function and other keys is disabled, excluding “HOLD” and “ ” keys. To prevent accidental loss of MAX, MIN and MAXMIN, in this mode can only be cancelled by pressing and holding down the “MAX/MIN” key for 2 seconds to exit and erased recorded reading.
“>2S APO/ENTER” Button
Pressing and holding down “APO” key for 2 seconds to trigger on or off APO mode, and then APO annunciator will appear or disappear on the display. Power is automatically turn off, if no operation for a period of time, and “APO” annunciator is displayed at upper-left corner when APO function is enabled.
SPECIFICATION
Electrical
Temperature Scale
Measurement Range
Auto range 0.1°C/1°C, 0.1°F/1°F
Celsius or Fahrenheit user-selectable
K-TYPE(0.1°C) -200°C to 1372°C, -328°F to 1999°F
5
Page 13
Accuracy Accuracy is specified for operating
temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error.
±(0.1%rdg+1°C) on -60°C to 1372°C ±(0.1%rdg+2°C) on -60°C to -200°C ±(0.1%rdg+2°F) on -76°F to 1999°F ±(0.1%rdg+4°F) on -76°F to -328°F
Environmental
Ambient Operating Ranges
Storage Temperature
0°C to 50°C (32°F to 122°F) <80% R.H.
-20°C to 60°C (-4°F to 140°F) <80% R.H.
with battery removed from meter.
General
Low battery Indication
Measurement rate
Accuracy Stated accuracy at 23°C±5°C, <75% R.H.
Battery 1.5V x 4pcs AAA size
Battery Life 200 hours typical with carbon zinc
Dimensions 160mm(H) x 83mm(W) x 38mm(D);
Weight Approx. 240g (0.5lb) including batteries.
The “ ” is displayed when the battery voltage drops below the operating level.
2.5 times/second.
battery.
6.3 in (H) x 3.3 in (W) x 1.5 in (D).
6
Page 14
 - EMC: Conforms to EN61326-1.
This product complies with requirements of the
following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference.
MAINTENANCE AND REPAIR
WARNING
To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover.
Installing and Replacing Battery
A. Screw B. Battery Cover C. Battery
7
Page 15
1. Power is supplied by 4pcs 1.5V (SIZE AAA) UM-4
R03.
2. The “
3. Remove the batteries from the battery
4. When not use for long time, remove the battery.
5. Do not store the unit in place with temperature
” appears on the LCD display when replacement is needed. To replace battery remove screw from back of meter and lift off the battery cover.
compartment and replace them with new ones.
and humidity beyond the recommended storage temperature.
Cleaning
Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents.
8
Page 16