Amprobe AM-250 Data Sheet

Data Sheet
AM-250
Professional Electrical Multimeter
A professional multimeter for Electrical and HVAC applications. Safety rated to CAT III 600V and CAT II 1000V for indoor applications requiring direct connection to main panel of the building. The AM-250 measures complete range of electrical parameters including voltage, current, resistance and frequency. It also covers HVAC application with temperature, capacitance and micro amps functions.
13 Features
Measures AC/DC voltage up to 1000V, Current,
Resistance, Frequency, Capacitance and Temperature
Audible continuity
No hassle warranty
No waiting.
No shipping charges.
Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot.
(note: $500 MSLP limit)
Diode Test
Auto and manual ranging
Relative zero mode
Data hold
Peak hold (30ms response time)
Backlight display
Large, easy to read LCD display
BEEP-JACK audible warning against improper
connection
Auto power off
Safety CAT III 600V
Amprobe® Test Tools
AM-250 Professional Electrical Multimeter
Data Sheet
Specifications
General Specifications Display 3-3/4 digits 4000 counts LCD display Polarity Automatic Update Rate 3 per second nominal Operating Temperature 0°C to 40°C (32°F to 104°F) Relative Humidity Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative
humidity at 40°C
Altitude Operating below 2000m Storage Temperature -20°C ~ 60°C (-4°F to 140°F), < 80% R.H. (with battery removed) Temperature Coefficient nominal 0.15 x (specified accuracy)/ºC @(0°C - 18°C or 28°C - 40°C), or otherwise specified Sensing Average sensing Pollution Degree 2 Safety The meter (all versions) is protected, against the users, by double insulation per UL3111-1
(1st Edition), IEC61010-1 (1st Edition) + A1 and A2, CAN/CSA - C22.2 No. 1010.1 - 92 to CAT II 1000V & CAT III 600V. Protection-reinforced CE Terminals (to COM) ratings: V: Category II 1000 Volts AC & DC, and Category III 600 Volts AC & DC. A / mAµA: Category III 500 Volts AC and 300 Volts DC.
Overload Protections
Protection-reinforced CE µA & mA: 0.63A/500V, IR200kA, F Fuse;
A: 12.5A/500V, IR20kA, F Fuse; V: 1050Vrms, 1450Vpeak; & Others: 600VDC/ VAC rms
E.M.C . Meets EN61326(1997, 1998/A1), EN61000-4-2(1995), and EN61000- 4-3(1996)
In an RF field of 3V/m Capacitance function is not specified AC 4.000V range: Total Accuracy = Specified Accuracy + 700
digits AC 400.0µA range: Total Accuracy = Specified Accuracy + 300 digits Other function ranges: Total Accuracy = Specified Accuracy + 40 digits Performance above 3V/m is not specified
Transient protection 6.5kV (1.2/50µs surge) Power Supply 1.5V AA A Size (NEDA 24A or IEC LR03) battery X 2 Power Consumption 3.2 mA typical Low Battery Below approx. 2.4V Sleep Mode Timing Idle for 30 minutes Sleep Mode Consumption 360µA Dimension 193(L) x 97(W) x 46(H)mm (7.6 X 3.8 X 1.8 in) Weight Approx. 370 gm / 0.815 lb Special Features 25ms Max Hold; Data Hold; Relative zero mode; Beep-jack™ input warning; Back-lighted display
Amprobe® Test Tools
Loading...
+ 2 hidden pages