ALC-110
Leakage Current Clamp
Prevent unplanned downtime by detecting leakage currents with the
ALC-110 Leakage Current Clamp. Rated CAT III 600 V to ensure electrical
safety, the ALC-110 is designed to resist external magnetic fields for
highly accurate readings.
Features
• Low influence of external low frequency
magnetic fields: @ I
≤ 30 A/m, operating class 2
• True-rms measurements for accuracy when
measuring complex, non-sinusoidal waveforms
• Mechanical jaw lock to assure accuracy of low
current measurements, avoiding disturbance
from measured wires and magnetic fields;
jaw opening 1.2 in (30 mm)
• Highest resolution of 0.001 mA,
measure up to 60 A
• Broad frequency range 15 Hz to 1 kHz for
a variety of different applications, including
industrial and railway
• Selectable filters:
- Low Pass 50/60Hz filter to perform
measurements on equipment driven by Variable
Frequency Drives (VFDs) or affected by high
frequency noise
- Appliance Filter to conduct leakage current
measurements on appliances
- No filter
• Selectable limits:
0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
• Max readings and hold function
• High safety rating: CAT III 600 V
• Battery-saving design with an auto backlight off
and auto power off
N: 3.500 mA – 600.0 mA
amprobe.com
Mechanical jaw lock
for high accuracy
readings
Finger guard for
safe usage
Robust, strong
rubber housing for
easy grip
Large digital
display with bar
graph and filter
function
Applications
• Measure:
- Earth and differential leakage currents
- Leakage currents through the earth (PE)
conductor
- Appliance current consumption without
interruptions to the circuit
• Trace the source of earth leakage current
• Identify intermittent GFCI trips without
switching equipment off
• Check a system for an electrical break of
insulation where current is flowing to the ground
• Where industrial leakage current testing
is required
Electrical
ALC-110
Safety
Leakage Current Clamp
6
Safety Certification
All Amprobe tools, including the Amprobe ALC-110, are rigorously tested
for safety, accuracy, reliability, and ruggedness in our state-of-the-art
test lab. In addition, Amprobe products that measure electricity are listed by a
3rd party safety lab, either UL or CSA. This system assures that Amprobe products
meet or exceed safety regulations and will perform in a tough, professional
environment for many years to come.
©2019 Amprobe® For detailed specications and ordering go to amprobe.com 6011715 AAmprobe® | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
Specifications
Features ALC-110
Complies with IEC/EN 61557-13 •
Built according IEC/EN 61010-2-032 •
Low frequency magnetic fields ≤ 30 A/m, operating class 2 @ I
Safety, measurement category CAT III 600 V
True-rms •
AC frequency 15 Hz to 1 kHz
Low pass filter 50 Hz to 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter
Limit judgement 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
Jaw opening 1.2 in (30 mm) max.
Jaw locking •
Data hold •
Backlight function •
Overload protection 60 A
Auto power off Idle 20 minutes
Auto ranging •
Max hold •
AC current
[1]
Add 4.0% for C.F. 2.5 to 3.0. Position error of clamp: +/- 1% of LCD reading.
[2]
[3]
[1] [2] [3]
Range Resolution
6.000 mA 0.001 mA ±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
60.00 mA 0.01 mA ±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
600.0 mA 0.1 mA ±(5.0%+5D) ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
6.000 A 0.001 A Unspecified ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
60.00 A 0.01 A Unspecified ±(2.0%+5D) ±(1.0%+5D) ±(2.0%+5D)
Crest Factor (C.F.) may be up to 3.0 as 3000 counts. For non-sinusoidal waveforms: Add 1.0% for C.F. 1.0 to 2.0 / Add 2.5% for C.F. 2.0 to 2.5 /
Minimum reading is 0.010 mA.
When operating in magnetic fields up to ≤ 30 A/m, add ±0.3 mA error to accuracy.
15 Hz to 40 Hz > 40 Hz to 50 Hz > 50 Hz to 60 Hz > 60 Hz to 1 kHz
N : 3.500 mA to 600.0 mA / 40 Hz to 1 kHz
Accuracy
amprobe.com
General Specifications
Display Digital: 6000 counts, updates 5/sec
Range Auto ranging
Over range indication OL or -OL
Operating temperature
Operating altitude ≤ 2000 m
Storage temperature -4 °F to 140 °F (-20 °C to 60 °C)
Pollution degree 2
Temperature coefficient 0.1 x (specified accuracy) / °C (<21 °C, >25 °C)
Vibration requirement acc. IEC 61557-1 clause 4.10
Drop proof 4 ft (1.2 m)
Battery 2 x batteries 1.5 V IEC LR03 AAA
Battery life 60 hours typical
Low battery indication
Safety compliance IEC/EN 61010-1, IEC/EN 61010-2-032, IEC/EN 61557-13
EMC compliance IEC/EN 61326-1, IEC/EN 61326-2-2
Agency approvals
Dimensions (H x W x L) 8.7 x 3.5 x 1.8 in (221 x 89 x 48 mm)
Weight 0.9 lb (410 g) with batteries installed
Included: 2 x AAA batteries, soft carrying case and user manual
32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH
86 °F to 104 °F (30 °C to 40 °C), ≤ 75% RH
104 °F to 122 °F (40 °C to 50 °C), ≤ 45% RH
©2019 Amprobe® For detailed specications and ordering go to amprobe.com 6011715 AAmprobe® | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)