AF-600 A-Frame
Ground Fault Locator
Save time and money by pinpointing
leakage points
Ground faults are a common problem with
electrical cables. Find any fault with the
AF-600 A-Frame cable ground fault locator,
specically designed for use with the Amprobe
UAT-600 Series.
Set up the UAT-600-T Transmitter to apply a
fault nd signal to the utility under test, the
AF-600 A-Frame receives the signal and locates
the place of the fault. The AF-600 will pinpoint
where a cable metal conductor (either a sheath
or a metallic conductor of the wire) touches the
ground and can also detect other conductors to
ground faults such as pipeline coating defects.
Detect ground
faults on cables
and pipes
AF-600-A-Frame
Ground Fault Locator
LCD Display
with auto
backlight
amprobe.com
Features and Highlights Specifications
• Identify any point of leakage around a cable
• Locate cable and wire ground faults, sheath
faults or pipeline coating defects, where the
utility is in direct contact with the ground
• Find the exact point where metal is touching
the ground and power is leaking, ie, a shield is
rusted or a rubber buffer is broken, creating
noise on a cable
• Advanced technology and digital signal
processing makes pinpointing process fast,
accurate and clear:
- Compass guidance with numeric fault eld
strength indicates the direction of the fault
- Distance sensitive left and right arrows
guides the user to precisely follow the path
of the buried utility
- Automatic gain control quickly detects
tracing signal and precisely adjusts the
A-Frame sensitivity
- Adjustable volume controls
Tracing mode (de-energized) 8 kHz
Locating mode Ground fault locating
Sensitivity (typical)
Display backlight Automatic
Audio indication Speaker indicates left/right by pulsed/continuous tone
Compatible transmitter UAT-600-T Transmitter
Display 1.28 in, 128 x 128 BW outdoor LCD display with auto backlight
Update rate Instantaneous
Operating temperature and humidity -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH
Storage temperature and humidity -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH
Operating altitude < 6561 ft (< 2000 m)
Pollution degree 2
Water and dust resistance IP54
Drop proof 3.28 ft (1 m)
Power supply (6) 1.5 V AA alkaline batteries
Auto power off 15 minutes idle
Battery life Approx. 60 hours at 70 °F (21 °C) (Typical)
Certications
Safety compliance IEC 61010-1, CSA/UL 61010-1
Size (H x W x L) Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm)
Weight Approx. 4.2 lb (1.9 kg) (batteries installed)
AF-600 A-Frame includes: A-Frame Receiver, (6) 1.5 V AA (IEC LR6) Batteries,
Carrying Case, User Manual
AF-600 A-Frame
Cable locate mode at 1 meter depth: 10 uA
Fault locate mode: up to 2 MΩ fault
The AF-600 comes complete with batteries
and a carrying case
Clearly view the LCD display in bright sunlight Pinpoint fault location by using the AF-600
with the UAT-600 Transmitter
©2018 Amprobe® For detailed specications and ordering go to amprobe.com 6011240 AAmprobe® | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)