Amprobe AD105A User Manual [en, de, es, fr]

AD105A
Users Manual
Bedienungshandbuch
Manuale de Uso
Mode d’emploi
PN 2729036 July 2006 ©2006 Amprobe
Test Tools.
All rights reserved. Printed in Taiwan
Limited Warranty and Limitation of Liability
Your Amprobe
product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe
’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe
Test Tools Service Center or to a
Amprobe
dealer or distributor. See Repair Section above for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
1
Digital Clamp-On Meter
Contents
Symbols.................................................................................................... 1
Warnings and Precautions ........................................................................ 1
Introduction .............................................................................................. 1
Instrument Familiarization (See Fig. 1) ..................................................... 2
Measuring Procedures.............................................................................. 2
Specifications............................................................................................ 3
Troubleshooting........................................................................................ 4
Battery Replacement .................................................................................4
Repair ....................................................................................................... 5
Symbols
B Battery W Refer to the manual
T Double
insulated
B Alternating Current
F Direct
Current
P
Complies with EU directives
Warnings and Precautions
This instrument is EN61010-1:2001 certified for Installation
Category III (1000 V). It is recommended for use in distribution level and fixed installations, as well as lesser installations, and not for primary supply lines, overhead lines and cable systems
This instrument must not be used on uninsulated conductors at a
voltage greater than 1000 V AC/DC
Do not exceed the maximum input limits per function (see
specifications), nor any ratings marked on the instrument itself
Never ground yourself when taking measurements. Do not touch
exposed metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body isolated from ground and never touch exposed wiring, connections, or any live circuit conductors
Do not operate the instrument in an explosive atmosphere
(flammable gases, fumes, vapor, dust)
Do not use this or any piece of test equipment without proper
training
Introduction
Your shipping carton should include the digital clamp meter, a carrying case, one 9 V battery (installed), a warranty card and this manual. If any of the items are damaged or missing, immediately return the complete package to the place of purchase for an exchange.
2
Instrument Familiarization (See Fig. 1)
1. Digital display: 3 ¾ digit LCD (max. reading 3999) plus auto polarity,
decimal point, N, ACB, DCF and P.
2. Wrist Strap: Prevents the instrument from slipping off the hand while
in use.
3. ON/OFF key.
4. Hz: This key selects the frequency mode. Press again to return to initial
function.
5. DCA AUTO Zero Key: Compensates the residual magnetism.
6. DC/AC Key: Selects between AC and DC current.
7. Jaw Opening Lever: Press lever to open transformer jaws. When
pressure on lever is released, the jaws close again.
8. Peak Hold Key: Press to hold the maximum measured value. P
annunciator is displayed.
9. Transformer Jaws: Designed to pick up the current flowing through the
conductor.
Measuring Procedures
AC Current/Frequency Measurement
1. Set the clamp meter to ACA mode by pressing DC/AC key.
2. Press the lever to open the transformer jaws and clamp one conductor
only, make sure that the jaw is firmly closed around the conductor.
3. Read the value from digital display.
4. To read frequency, press Hz key.
DC Current Measurement
1. Set the clamp meter to DCA mode by pressing DC/AC key.
2. Compensate the residual magnetism by pressing DCA Auto Zero key.
3. Press the lever to open the transformer jaws and clamp one conductor
only, make sure that the jaw is firmly closed around the conductor.
4. Read the value from digital display.
Note
For DC measurement, the reading is positive when the current flows from the upper side to the lower side of the instrument as shown in Fig. 1.
Peak Hold:
Depress the Peak Hold button to record maximum current values (RMS for AC current). Any new maximum signal will be automatically stored and displayed in the LCD. The P annunciator indicates the Peak Hold feature is invoked.
3
Specifications
General Specifications
Display: 3 3/4 Digit LCD, max. reading of 3999. Polarity indication: automatic, “–” indicated; “+” implied. Overrange Indication : “OL” or “– OL”. Range selection: automatic; Measuring Rate: 2 /sec, nominal. Position Error: ±1 % of Reading. Type of Sensing: Hall effect sensing for AC and DC. Low Battery Indication: N. Auto Power Off: approx. 30 minutes after power on.
Environmental Conditions
Operating Temperature: 0 °C to +50 °C, <75 % R.H. Storage Temperature: -20 °C to +60 °C, <80 % R.H., battery removed. Temperature Coefficient: 0.2 x (Spec.Acc’y) / °C, < 18 °C or > 28 °C. Power Requirement: Single 9 V PP3 battery (NEDA 1604,1EC 6F22) Battery Life: Alkaline 40 hours typical. Max / Conductor Size: 51 mm diameter or 24 x 60 mm busbar. Size (LxWxD): 240x106x40 mm (9.5”x4.2”x1.6”); Weight: 420 grams
(14.8 oz)
Accessories: Battery (installed), manual and carrying case.
Agency Approvals: P
Safety: Meets EN61010-1:2001 Cat III 1000V,Class 2, Pollution Degree 2;
EN 61010-2-032; EMC: EN50081-1, EN50082-1
EMC: This product complies with requirements of the following European
Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the vicinity of
the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference.
Electrical Specifications
Accuracy is ±(%reading + number of digits) at 23 °C ±5 °C, < 75 % R.H.
Overload Protection, all functions and ranges: 2000 A AC/DC for 1 minute.
DC Current (autoranging)
Range Resolution Accuracy: 0 to 100 A 0.1 A ±(2.9 %rdg + 8 dgt) 100 A to 400 A 0.1 A ±(1.9 %rdg + 5 dgt) 400 A to 1000 A 1 A ±(2.9 %rdg + 5 dgt)
4
AC Current (40 – 400 Hz; autoranging)
Range Resolution Accuracy: 0 to 40 A 0.1 A ±(1.9 %rdg + 8 dgt) 40 A to 400 A 0.1 A ±(1.9 %rdg + 7 dgt) 400 A to 1000 A 1 A ±(2.9 %rdg + 5 dgt)
AC Conversion Type: AC conversions are ac-coupled, true rms responding, calibrated to the rms value of a sine wave input. Accuracies are given for sine wave at full scale. For distorted signals, add the following corrections:
for Crest Factor of 1.4 to 2.0, add 1.0 % to accuracy. for Crest Factor of 2.0 to 2.5, add 2.5 % to accuracy. for Crest Factor of 2.5 to 3.0, add 4.0 % to accuracy (0 – 400 A).
Frequency Counter
Range Resolution Accuracy: 4 KHz 1 Hz ±(0.5 %rdg + 3 dgt) 10 KHz 10 Hz ±(0.5 %rdg + 3 dgt) Min. Input Frequency: 20 Hz Sensitivity at 1 kHz to 10 kHz: 10 A RMS (<1 kHz: 6 A RMS)
Peak Hold
Range Resolution Accuracy: LOW 0.1 A ±(3.0 %rdg + 10 dgt) HIGH 1.0 A ±(3.0 %rdg + 10 dgt)
Troubleshooting
If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem:
1. Check the battery.
2. Review the operating instructions for possible mistakes in operating
procedure.
3. Check clamp against a known current source. Except for the replacement of the battery, repair of the clamp should be
performed only by a Factory Authorized Service Center or by other qualified instrument service personnel.
Front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and let dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
Battery Replacement
This instrument is powered by a single 9 V battery. Use the following
procedure to replace battery.
Turn the instrument off. Position instrument face down, remove the two screws and lift off
back of case.
Replace battery, route wire away from top of battery and reassemble
case.
5
Repair
All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Please check the “Where to Buy” section on
www.amprobe.com for a list of distributors near you. Additionally, in the
United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center (see below for address).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates.
In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 888-993-5853 Tel: 905-890-7600 Fax: 425-446-6390 Fax: 905-890-6866
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge. Please check the “Where to Buy” section on www.amprobe.com for a list of distributors near you.
European Correspondence Address* Amprobe Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands
*(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor).
6
.
O O
P
/
O
A
Hz
I
9
3
2
7
4
1
5
8
6
AD105A
AD105A
Users Manual
Bedienungshandbuch
Manuale de Uso
Mode d’emploi
German

Deutsch

Beschränkte Gewährleistung und Haftungsbeschränkung
Es wird gewährleistet, dass dieses Amprobe
-Produkt für die Dauer von einem Jahr ab dem Kaufdatum frei von Material- und Fertigungsdefekten ist. Diese Gewährleistung erstreckt sich nicht auf Sicherungen, Einwegbatterien oder Schäden durch Unfälle, Nachlässigkeit, Missbrauch, Änderungen oder abnormale Betriebsbedingungen bzw. unsachgemäße Handhabung. Die Verkaufsstellen sind nicht dazu berechtigt, diese Gewährleistung im Namen von Amprobe
zu erweitern. Um während der Gewährleistungsperiode Serviceleistungen zu beanspruchen, das Produkt mit Kaufnachweis an ein autorisiertes Amprobe
Test Tools Service-Center oder
an einen Amprobe
-Fachhändler/-Distributor einsenden. Einzelheiten siehe Abschnitt „Reparatur“ oben. DIESE GEWÄHRLEISTUNG STELLT DEN EINZIGEN UND ALLEINIGEN RECHTSANSPRUCH AUF SCHADENERSATZ DAR. ALLE ANDEREN GEWÄHRLEISTUNGEN - VERTRAGLICH GEREGELTE ODER GESETZLICHE VORGESCHRIEBENE ­EINSCHLIESSLICH DER GESETZLICHEN GEWÄHRLEISTUNG DER MARKTFÄHIGKEIT UND DER EIGNUNG FÜR EINEN BESTIMMTEN ZWECK, WERDEN ABGELEHNT DER HERSTELLER ÜBERNIMMT KEINE HAFTUNG FÜR SPEZIELLE, INDIREKTE, NEBEN- ODER FOLGESCHÄDEN ODER VERLUSTE, DIE AUF BELIEBIGER URSACHE ODER RECHTSTHEORIE BERUHEN. Weil einige Staaten oder Länder den Ausschluss oder die Einschränkung einer implizierten Gewährleistung sowie von Begleit- oder Folgeschäden nicht zulassen, ist diese Gewährleistungsbeschränkung möglicherweise für Sie nicht gültig.