Amprobe ACD-6-TRMS-PRO Data sheet

No hassle
600V
warranty
No waiting.
No shipping charges.
Data Sheet
ACD-6 TRMS-PRO
1000A Clamp-on Multimeter
Simple to operate and well-suited for most basic applications. The TRMS version improves measurement accuracy in noisy electrical environments.
True RMS 1000 Amp AC current AC/DC voltage to 600V Resistance Continuity Beeper Relative zero mode Auto power off Data hold Carrying case included Large, easy to read LCD display Accommodates conductors up to 45mm
(1.77”) in diameter
ACD-6 TRMS-PRO
(note: $500 MSLP limit)
Amprobe® Test Tools
www.Amprobe.com
ACD-6 TRMS-PRO 1000A Digital Clamp-on Multimeter
Data Sheet
Electrical Specifications
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 °C ± 5 °C (73°F ± 9°F) & less than 75% R.H. True RMS Model ACD-6 TRMS-PRO ACV & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified.
Maximum Crest Factor are as specified below, and with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms.
Range Accuracy
DC Voltage
400.0 mV 1.0% + 3d
4.000V, 40.00V, 400.0V 1.7% + 3d 600V 2.0% + 4d
NMRR : >50dB @ 50/60Hz CMRR : >120dB @ DC, 50/60Hz, Rs=1kΩ Input Impedance: 10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
Audible Continuity Tester
Open Circuit Voltage: 0.4VDC typical 400.0Ω 1.5% + 6d Audible threshold: between 10Ω and 120Ω.
Resistance
400.0Ω 1.5% + 6d
4.000kΩ, 40.00kΩ, 400.0kΩ 1.0% + 4d
4.000MΩ 1.5% + 4d
40.00MΩ 2.5% + 4d Open Circuit Voltage: 0.4VDC typical
AC Voltage
50Hz -- 500Hz 400.0mV 50Hz -- 60Hz 4.000V, 40.00V, 400.0V 2.0% + 5d
60Hz -- 500Hz 4.000V, 40.00V, 400.0V 2.5% + 5d 50Hz -- 500Hz 600V 3.0% + 5d
CMRR : >60dB @ DC to 60Hz, Rs=1kΩ Input Impedance : 10MΩ, 30pF nominal
Crest Factor: < 2.5 : 1 at full scale & < 5.0 : 1 at half scale
1)
Selection by RANGE button manually, and is specified from AC 40mV (AC 60mV for True RMS model ACD-6 TRMS-PRO) and up
Diode Tester
Open Circuit < 1.6 VDC Voltage Test Current (Typical) 0.4mA
AC Current (Clamp-on)
50Hz / 60Hz 400.0A 1.5% + 5d 1000A 1.5% + 5d
Crest Factor: < 2.6 : 1 at full scale & < 5.2 : 1 at half scale
1)
Add 8d to specified accuracy while reading is below 15% of range
2)
Induced error from adjacent current carrying conductor: < 0.06A/A
3)
Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening)
1)
4.0% + 5d
Amprobe® Test Tools
www.Amprobe.com
Loading...
+ 2 hidden pages