Enjoy the versatility of improved technology. Amprobe offers basic power quality capability combined with TRMS clamp-on ammeter functionality.
• TRMS Measurements
• AC Current up to 400A
• AC/DC Voltage up to 600V
• Voltage and Current Harmonics up to 25th with THD% (ACD-55 HPQ and ACD- ACD-56 HPQ only)
• Power Factor, Cos Ø Single/Three Phase / Energy (ACD-51HP and ACD- ACD-56 HPQ only)
• Frequency (with test leads and jaw)
• Phase seqence with single wire (patented)
• Autoranging
• Auto Power OFF
• Backlight
• Data Hold
• MAX / MIN / AVG recording
• Fast PEAK function (1ms)
• Low battery indication
• Safety CAT III 600V
FEATURES ACD-51HP ACD-55HPQ ACD-56HPQ ACCURACY
AC/DC Voltage AC Peak Voltage @
1ms response time AC Current AC Peak Current @
1ms response time Resistance Frequency (with test
leads and jaw) Voltage / Current
Harmonics Active, Reactive and
Apparent Power Power Factor, Cos Ø
0.00 – 99.99 / 999.9 kW, kVAR, kVA
0.20 - 1.00 0.20 - 1.00 ±(2% Rdg + 2 LSD)
1.6 - 599.9 V ±(1% Rdg + 3 LSD) 10 to 850 V ±(5% Rdg + 10 LSD)
0 - 399.9 A ±(1% Rdg + 3 LSD) 10 to 800A ±(5% Rdg + 10 LSD)
0 – 499.9 / 999/ 1999 Ohms ±(1% Rdg + 5 LSD)
40.0 - 399.9 Hz ±(0.5% Rdg + 1 LSD)
THD, Individual harmonics 1 to 25 Harmonics 1 to 16
0.00 – 99.99 / 999.9 kW, kVAR, kVA
@ ±(10.0% rdg + 5 dgt)** ±(3.5% Rdg + 3 LSD)
www.AMPROBE.com
ACD-51HP, ACD-55HPQ, ACD-56HPQ Power & Power Quality Clamp-ons
OPTIONAL ACCESSORIES PART NUMBER
Line Splitter (Energizer) A47L 3000A AC Flexible Clamp-on Attachment ACF-3000 AK Single Input Thermocouple Temperature Attachment
Alligator Clips (For test leads) VRC-320
REPLACEMENT PARTS (supplied with product) PART NUMBER
Test lead holder MTL-CAP Carrying case SV-U Test leads with set of alligator clips
(alligator clips are not supplied with product)
SPECIFICATIONS Safety Standards
Comply with: EN 61010 Insulation: Class 2, double reinforced insulation Pollution: Level 2 For inside use, max height: 2000m Over voltage: CATIII 600V between terminals and ground
General Data
Mechanical Characteristics:
Size: 205(L) x 64 (W) x 39(D)mm Weight (including battery): about 280g Jaws opening: 30mm Max conductor size: 30mm
Power Supply:
Battery type: 2 batteries 1.5V AAA. Low battery indication: Symbol "" is displayed when battery level is too low. Battery life: About 90 hours of continued measurement Display Characteristics: 4 dgt LCD with maximum reading 9999 units plu
decimal point and sign. Sample rate: 64 samples in 20ms Conversion mode: TRMS
Environmental Conditions
Climatic Conditions:
Reference temperature: 23° ± 5°C Operating temperature: 5 - 40 °C
TMA-K
MTL-90B
CAT
600V
Operating humidity: <80% RH Storage temperature: -10 - 60 °C Storage humidity: <80% RH
EMC:
This apparatus was designed in accordance with EMC standards in force and its compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).
This product conforms to the prescriptions of the European directive on low voltage 73/23/EEC (LVD) and to EMC directive 89/336/EEC, amended by 93/68/EEC.
Accessories
Standard accessories: