J-12T TECHNICAL SPECIFICATIONS
OUTPUT POWER RATING 15 Watts RMS @ 5 % THD 8 ohm load 120 VAC SIGNAL TO NOISE RATIO 70dB Typical POWER REQUIREMENTS Domestic: 750mA, 100/120 VAC, 60 Hz
Export: 375mA, 220/240 VAC, 50 Hz
GAIN 62 dB TONE 30 dB Boost and Cut @ 4 kHz SPEAKER SPECS 12”, 20 w, 8 ohm, 1” voice coil diameter, 15 oz. magnet SIZE AND WEIGHT 18.75” W x 16” H x 10” D
30 lbs.
THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELIABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENT ACCIDENTALDAMAGES OR INJURY, PLEASE FOLLOW THESE PRECAUTIONARYGUIDELINES:
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEATOR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROPERLY GROUNDED AC POWER OUTLET.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. CAUTION: NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION: IF YOU USE AUDIO AMPLIFIERS PROFESSIONALLYOR IN WORK RELATED SITUATIONS AS AN EMPLOYEE, THE OCCUPATIONAL SAFETY
AND HEALTH ADMINISTRATION (OSHA) HAS SPECIFIED REGULATIONS CONCERNING PROLONGED EXPOSURE TO HIGH SOUND PRESSURE LEV­ELS. PLEASE REFER TO THE CODE OF FEDERAL REGULATIONS DOCUMENT29CFR1910 FOR ADDITIONALINFORMATION.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER.
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION
RISQUE D'ELECTROCUTION
NE PAS OUVRIR
ATTENTION: POUR REDUIRE D'ELECTROCUTION NE PAS
ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE N'EST REPRABLE
PAR L'UTILISATEUR. POUR TOUTE REPARATION, S'ADRESSER A UN
TECHNICIEN QUALIFIE.
VORSICHT
ELEKTRISCHE SCHLAGGEFAHR
NICHT OFFENEN
VORSICHT: ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGEFAHR NICHT
DEN DECKEL ABENHMEN. INTERNE TEILE KONNEN NICHT VOM
BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM
WARTUNGSPERSONAL ZU UBERLASSEN.
"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL" "REFERREZ-VOUS AU MANUAL D'UTILISATION" "UNBEDINGT IN DER BEDIENUNGSANLEITUNG NACHSCHLAGEN"
EXPLANATION OF GRAPHICAL SYMBOLS:
"DANGEROUS VOLTAGE" "DANGER HAUTE TENSION" "GEFAHLICHE SPANNUNG"
=
=
Specs and other information subject to change without notice.
Ampeg is proudly Made in America. Aproduct of SLM Electronics, 1400 Ferguson Avenue, St. Louis, MO 63133 U.S.A.
47-277-02 • 12-95
MODEL J-12TMODEL J-12T
GUITAR ACCORDION
VOLUME
0
1
2
3
4
5
6
7
8
9
10
ON
OFF
TONEB
0
1
2
3
4
5
6
7
8
9
10
SPEED
0
1
2
3
4
5
6
7
8
9
10
INTENSITY
TREMOLO
0
1
2
3
4
5
6
7
8
9
10
JET II
T DIMENSION
REVERB
0
1
2
3
4
5
6
7
8
9
10
1 2 3 4 5 6 7 8 9
Thank you for selecting the Ampeg Classic Jet guitar amplifier. Revived from the sixties and ready for the nineties, this easy-to-use amplifier represents Ampeg’s quest to provide you the finest instrument amplification systems available. In order to get the most out of your new amplifier, please read these instructions before its use.
THE FRONT PANEL:
1. Guitar Input accepts a stan­dard 1/4” instrument plug from your electric guitar. This input is at 0dB level.
2. Accordion Input accepts a standard 1/4” instrument plug from high output electronic instruments. This input is padded 6dB to com­pensate for higher output sources.
3. V olume controls the overall out­put level of the amplifier. At lower volume settings the sound will be clean. As you push the volume higher and crank your guitar the sound becomes distorted.
4. Tone controls the overall tonal character of the amplifier. Rotating the knob toward the “T” increases the higher frequencies, giving a brighter, more “crisp” sound. Rotating the control towards the “B” reduces the high frequencies, giving a darker, more “muffled” sound. The Tone control offers a cut or boost of 30dB at 4kHz.
5. Tremolo-Speed sets the rate at which the tremolo effect “vibrates.” The Tremolo-Intensity control (#6) must be turned up to hear the effects of this knob’s setting.
6. Tremolo-Intensity sets the depth of the tremolo effect. For slow, smoother vibrato effects try the Intensity control at around 6 and the Speed control at 1. For the really wild sounds, crank the Intensity up towards 8 (or beyond) and go from there.
7. Reverb-Dimension controls the amount of reverberation applied to the signal. With the con­trol at the “0” position there is no reverb applied; as the control is turned towards “10” the amount of reverb increases accordingly.
8. Power light indicates the ampli­fier is turned on by glowing an iri­descent blue color.
9. Power switch is used to turn the amplifier on and off.
THE REAR
PANEL:
10. Power cord connects the amplifier to a suitable source of A.C. voltage. This is a grounded, three-wire cord and must be con­nected to a properly grounded out­let. DO NOT attempt to defeat
the ground connection of the power cord! If your amp was pur-
chased outside of the United States, see the sticker next to the A.C. connector for its power rat­ings. Follow the above guidelines.
11,12. Power Tubes: EL84 / 6BQ5 (2)
13. Power Amp Phase Splitter Tube: 12AX7A / 7025 (1)
14. Preamp Tube: 12AX7A/ 7025
(1) Replace tubes ONLY with same
types! Refer to enclosed publica­tion about Tubes and Tube Amplifiers for additional informa­tion.