19
Control Panel Causes Solutions
Light indicators:
OFF
A) Burned fuse Replace the fuse
B) Break is Off Put the breaker On
C) Pump doesn’t work Replace the pump
EO
twinkle
A) Pump is blocked Remove impurities
B) Pump doesn’t work Replace the pump
E4
twinkle
Over voltage or under
voltage
Check the value of the voltage
P5
twinkle
Pump doesn’t work Replace the pump
0
Pump is blocked
Press MODE button for 2
seconds, within 5 min from
the block*
E2 Pump doesn’t work Replace the pump
WARNING!!!
Before any electrical work, make sure the power switch is in the off position.
Problems Solving
*If the pump does not start again in a few minutes, one of these LEDs,
EO, E4, P5, E2, will be displayed.
Product Overview
1. AMICO
The AMICO Circulator is synonymous of quality and safety.
Quiet and powerful, it is designed to ensure a considerable energy saving.
It is suitable for domestic applications, heating systems and hot water circulation. Innovative and easy to install, it is used in heating and air conditioning systems.
The permanent magnet technology, combined with the frequency converter, allowing the engine to run automatically, according to the real
needs.
2. Main Features
1) Simple and compact structure.
2) Different adaptive control modes.
3) Combine control over two different compression pressure differences.
4) Display actual consumption power.
5) Low noise.
6) Energy-saving setup (Auto Night Mode).
7) Permanent magnet motor and compact design of stator.
8) Intelligent frequency conversion system
9) Coefficient EEI ≤ 0,22
10) Protection grade: IP42
11) Pressure: Max. 1,0MPa (10Bar)
3. Settings
1) The operating point of the water can be: "constant flow " or "variable
flow".
2) You can set three (3) different "fixed speed" (I, II, III).
3) Temperature variation system.
4. Pumping liquid
Clean, thin, non-aggressive and non-explosive liquid without solid particles or mineral oils.
The pumping liquid should meet the water quality standard involved, both
in heating systems and in recirculation systems of sanitary water.
Liquid temperature range: +2 °C to +110 °C