General Information
UEnglish
1. GeneralInformation
UEnglish
1. GeneralInformation
1.1. Designated Use
1.1.1. Intended purpose
Minor surgical luminaire (Treatment light) – light for local illumination of the patient’s body during diagnosis or treatment. It is not intended for use inoperating theatres.
1.1.2. Location
Only in dry rooms not subject to the risk of explosion. The minimum distance to inflammable parts has to be 0.5m.
1.1.3.Operation mode
The light is designed for continuous operation.
2. SafetyInstruction
The light may only be operated in dry rooms, not subject to the risk of explosion.
Do not leave the light on without supervision.
The minimum distance to inflammable parts has to be 0.5 m.
Keep inflammable substances and objects away from the light and the light cone.
When using lights of protection class I make sure that the grounding conductor is connected with the lamp housing.
Do not touch the luminous medium while the light is switched on and for some time afterwards – danger of burns.
Defective apertures must be replaced – Riskofinjury.
Designated Use
Intended Purpose
Minor surgical luminaire (Treatment light) – light for local illumination of the patient’s body during
diagnosis or treatment. It is not intended for use in operating theatres.
Location
Only in dry rooms not subject to the risk of explosion. The minimum distance to inammable parts
has to be 0.5 m.
Operation Mode
The light is designed for continuous operation.
Safety Instructions
• The light may only be operated in dry rooms, not subject to the risk of explosion.
• Do not leave the light on without supervision.
• The minimum distance to inammable parts has to be 0.5 m.
• Keep inammable substances and objects away from the light and the light cone.
• When using lights of protection class I make sure that the grounding conductor is
connected with the lamp housing.
• Do not touch the luminous medium while the light is switched on and for some
time afterwards – danger of burns.
• Defective apertures must be replaced – Risk of injury.
• Apart from changing the lamps, no further modications or work may be carried
out by the user.
• Defective lamps may only be replaced with lamps with the same power (W, Watt)
and of the same type (specications see ’Technical Data’ at page 11 ).
• Do not kink the power supply cable to avoid damages.
• Do not touch the protective glass.
• The user has to comply with the requirements of the national institute for hygiene
and disinfection. Risk: Transmission of diseases.
www.amico.com 3
Page 4
Abbreviations and Symbols
3. Abbreviation and Symbols
Attention, observe accompanying documents
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
Defective shades must be replaced
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
Defective shades must be replaced
Symbol for separate disposal according the regulation 2002/96/EC (WEEE - Waste Electrical and Electronic Equipment)
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
Defective shades must be replaced
Symbol for separate disposal according the regulation 2002/96/EC (WEEE - Waste Electrical and Electronic Equipment)
UL-Conformity mark (USA + Canada)
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
Defective shades must be replaced
Symbol for separate disposal according the regulation 2002/96/EC (WEEE - Waste Electrical and Electronic Equipment)
UL-Conformity mark (USA + Canada)
VDE-Conformity mark
3. Abbreviation and Symbols
Attention, observe accompanying documents
Device of international protection class I (protective earth)
I
ON
0
OFF
I
ON (stage I = 60%)
II
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5m to inflammable parts
Defective shades must be replaced
Symbol for separate disposal according the regulation 2002/96/EC (WEEE - Waste Electrical and Electronic Equipment)
UL-Conformity mark (USA + Canada)
VDE-Conformity mark
CE-Conformity mark
Attention, observe accompanying documents
Device of international protection class I (protective earth)
ON
OFF
ON (stage I = 60%)
ON (stage II = 100%)
Attention! Hot surface
Keep the minimum distance of 0.5 m to inammable parts
Defective shades must be replaced
4 Amico Lighting Solutions
Separate disposal according the regulation 2002/96/EC
(WEEE - Waste Electrical and Electronic Equipment)
UL-Conformity mark (USA + Canada)
VDE-Conformity mark
CE-Conformity mark
The manufacturer cannot be held liable for damages caused if the light is used for other purposes
!
than the intended purpose or if safety instruction and warnings are ignored.
Page 5
Operating manual (GB)
4. Assemblyand Installation MIRA 45Single Ceiling
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Single Ceiling. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The ceiling fitting is to be used exclusively at ceilings that are either solid, or supplied with a suitable high-strength ceiling-mounting solution.
cDrill holes in accordance to the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque).
dPerform this Step on a flat and level surface. Pull the cable through the
support tube. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (see detailed view 1 part ‘a’). Slide the arm and support tube together (view 1, direction ‘b’). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screwinto the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Check: Set-screwhas to be flush.
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and fix it temporarily, using supplied bolts (see detailed view 2). Align the support tube to the direction of the fixture’s general usage. Tighten the screws on the anchor plate. Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring upwards.
4. Assemblyand Installation MIRA 45Single Ceiling
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Single Ceiling. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The ceiling fitting is to be used exclusively at ceilings that are either solid, or supplied with a suitable high-strength ceiling-mounting solution.
cDrill holes in accordance to the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque).
dPerform this Step on a flat and level surface. Pull the cable through the
support tube. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (see detailed view 1 part ‘a’). Slide the arm and support tube together (view 1, direction ‘b’). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screwinto the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Check: Set-screwhas to be flush.
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and fix it temporarily, using supplied bolts (see detailed view 2). Align the support tube to the direction of the fixture’s general usage. Tighten the screws on the anchor plate. Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring upwards.
fHead Assembly (see page 68)
Before mounting the MIRA 45Single Ceiling, take heed of the operating range.
Assembly and Installation MIRA 45 Single Ceiling
Note: Only qualied technicians should carry out MIRA 45 installation.
Mounting steps
Detailed view 1
Detailed view 2
Before mounting the MIRA 45 Single Ceiling, take
Two people are required for assembling the MIRA 45 Single Ceiling. The supply voltage
must correlate with the voltage noted on the xture’s rating label. The ceiling tting is
to be used exclusively at ceilings that are either solid, or supplied with a suitable highstrength ceiling-mounting solution.
1. Drill holes in accordance to the enclosed drilling template (Ø=8 mm; depth=55
mm). Clean out the drilled holes. Attach the anchor plate using the four anchor
bolts. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an
open-ended wrench (approx. 3-4 turns, 23Nm torque).
2. Perform this Step on a at and level surface. Pull the cable through the support
tube. Insert the slider into the groove of the arm joint, noting the location of the
xing hole (see detailed view 1 part ‘a’). Slide the arm and support tube together
(view 1, direction ‘b’). Align the hole in the slider with the set-screw hole at the
bottom of the support tube. Insert the set-screw into the hole to lock the slider
in place (1c). Tighten the set-screw completely, then loosen it by a maximum
1-quarter turn and check the operation of the arm joint. Check: Set-screw has to
be ush.
3. Place the O-ring and the ceiling cover over the support tube. Insert the support
tube into the anchor plate and x it temporarily, using supplied bolts (see detailed
view 2). Align the support tube to the direction of the xture’s general usage.
Tighten the screws on the anchor plate. Now connect to the electrical power
supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide
the ceiling cover and the O-ring upwards.
4. Head Assembly (see page 68) Before mounting the MIRA 45 Single Ceiling, take
heed of the operating range.
heed of the operating range.
www.amico.com 5
Page 6
Operating manual (GB)
5. Assemblyand Installation MIRA 45Double Ceiling
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Double Ceiling. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The ceiling fitting is to be used exclusively with ceilings that are either solid, or supplied with a suitable high-strength ceiling-mounting solution.
cDrill holes in accordance with the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque.
dPerform this Step on a flat and level surface. Pull the cable through the
bearing head. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (1a). Align the hole in the slider with the set-screw hole at the bottom of the bearing head. Insert the set-screw (18 mm) into the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Check: Set-screws hadto be flush. Pull the cable through the cover (1d) and the support tube (1e). Insert the slider into the groove of the arm joint, noting the location of the fixing hole(1f). Slide the support tube and the bearing head together (1e). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screw (10 mm) into the hole to lock the slider in place (1g). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Fix the cover (1d) with the four screw (1h) Check: Set-screwhas to be flush.
Detailed view 2
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and fix it temporarily, using supplied bolts (see detailed view 2). Align the support tube to the direction of the fixture’s general usage. Tighten the screws on the anchor plate. Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring upwards.
5. Assemblyand Installation MIRA 45Double Ceiling
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Double Ceiling. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The ceiling fitting is to be used exclusively with ceilings that are either solid, or supplied with a suitable high-strength ceiling-mounting solution.
cDrill holes in accordance with the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque.
Detailed view 1
dPerform this Step on a flat and level surface. Pull the cable through the
bearing head. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (1a). Align the hole in the slider with the set-screw hole at the bottom of the bearing head. Insert the set-screw (18 mm) into the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Check: Set-screws hadto be flush. Pull the cable through the cover (1d) and the support tube (1e). Insert the slider into the groove of the arm joint, noting the location of the fixing hole(1f). Slide the support tube and the bearing head together (1e). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screw (10 mm) into the hole to lock the slider in place (1g). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint. Fix the cover (1d) with the four screw (1h) Check: Set-screwhas to be flush.
Detailed view 2
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and fix it temporarily, using supplied bolts (see detailed view 2). Align the support tube to the direction of the fixture’s general usage. Tighten the screws on the anchor plate. Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring upwards.
fHead Assembly (see page 8)
Assembly and Installation MIRA 45 Double Ceiling
Note: Only qualied technicians should carry out MIRA 45 installation.
Two people are required for assembling the MIRA 45 Double Ceiling. The supply voltage
must correlate with the voltage noted on the xture’s rating label. The ceiling tting is to
be used exclusively with ceilings that are either solid, or supplied with a suitable highstrength ceiling-mounting solution.
1. Drill holes in accordance with the enclosed drilling template (Ø=8 mm; depth=55
Detailed view 1
mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts.
Tap the anchor bolts completely in, using a hammer. Tighten the nut with an openended wrench (approx. 3-4 turns, 23Nm torque.
2. Perform this Step on a at and level surface. Pull the cable through the bearing head.
Insert the slider into the groove of the arm joint, noting the location of the xing hole
(1a). Align the hole in the slider with the set-screw hole at the bottom of the bearing
head. Insert the set-screw (18 mm) into the hole to lock the slider in place (1c).
Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and
check the operation of the arm joint. Check: Set-screws had to be ush. Pull the cable
through the cover (1d) and the support tube (1e). Insert the slider into the groove
of the arm joint, noting the location of the xing hole (1f). Slide the support tube
and the bearing head together (1e). Align the hole in the slider with the set-screw
hole at the bottom of the support tube. Insert the set-screw (10 mm) into the hole
to lock the slider in place (1g). Tighten the set-screw completely, then loosen it by a
maximum 1-quarter turn and check the operation of the arm joint. Fix the cover (1d)
with the four screw (1h) Check: Set-screw has to be ush.
3. Place the O-ring and the ceiling cover over the support tube. Insert the support tube
into the anchor plate and x it temporarily, using supplied bolts (see detailed view
2). Align the support tube to the direction of the xture’s general usage. Tighten the
screws on the anchor plate. Now connect to the electrical power supply, as per the
wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and
the O-ring upwards.
4. Head Assembly (see page 8)
6 Amico Lighting Solutions
Mounting steps
Page 7
6. Assemblyand Installation MIRA 45Wall Mount
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Wall Mount. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The wall fitting is to be used exclusively with walls that are either solid, or supplied with a suitable high-strength wall-mounting solution.
cDrill holes in accordance with the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts according to detailed view 2. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque.
dPerform this Step on a flat and level surface. Pull the cable through the
support tube. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (see detailed view 1 part ‘a’). Slide the arm and support tube together (view 1, direction ‘b’). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screwinto the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint.
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and install the locking bolt (Detailed view 2a) from top. Tighten the screws on the anchor plate. Observe the correctorder of the washer (2b) and the serrated lock washer (2c). Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring to the anchor plate.
6. Assemblyand Installation MIRA 45Wall Mount
Note: Onlyqualified technicians should carryout MIRA 45installation.
Two people are required for assembling the MIRA 45Wall Mount. The supply voltage must correlate with the voltage noted on the fixture’s rating label. The wall fitting is to be used exclusively with walls that are either solid, or supplied with a suitable high-strength wall-mounting solution.
cDrill holes in accordance with the enclosed drilling template (∅=8mm;
depth=55mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts according to detailed view 2. Tap the anchor bolts completely in, using a hammer. Tighten the nut with an open-ended wrench (approx. 3-4turns, 23Nm torque.
dPerform this Step on a flat and level surface. Pull the cable through the
support tube. Insert the slider into the groove of the arm joint, noting the location of the fixing hole (see detailed view 1 part ‘a’). Slide the arm and support tube together (view 1, direction ‘b’). Align the hole in the slider with the set-screw hole at the bottom of the support tube. Insert the set-screwinto the hole to lock theslider in place (1c). Tighten the set-screw completely, then loosen it by a maximum 1-quarter turn and check the operation of the arm joint.
ePlace the O-ring and the ceiling cover over the support tube. Insert the
support tube into the anchor plate and install the locking bolt (Detailed view 2a) from top. Tighten the screws on the anchor plate. Observe the correctorder of the washer (2b) and the serrated lock washer (2c). Now connect to the electrical power supply, as per the wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and the O-ring to the anchor plate.
fHead Assembly (see page 68)
Assembly and Installation MIRA 45 Wall Mount
Note: Only qualied technicians should carry out MIRA 45 installation.
Two people are required for assembling the MIRA 45 Wall Mount. The supply voltage must
correlate with the voltage noted on the xture’s rating label. The wall tting is to be used
exclusively with walls that are either solid, or supplied with a suitable high-strength wallmounting solution.
1. Drill holes in accordance with the enclosed drilling template (Ø=8 mm; depth=55
mm). Clean out the drilled holes. Attach the anchor plate using the four anchor bolts
according to detailed view 2. Tap the anchor bolts completely in, using a hammer.
Tighten the nut with an open-ended wrench (approx. 3-4 turns, 23Nm torque.
Detailed view 1
2. Perform this Step on a at and level surface. Pull the cable through the support tube.
Insert the slider into the groove of the arm joint, noting the location of the xing
hole (see detailed view 1 part ‘a’). Slide the arm and support tube together (view 1,
direction ‘b’). Align the hole in the slider with the set-screw hole at the bottom of the
support tube. Insert the set-screw into the hole to lock the slider in place (1c). Tighten
the set-screw completely, then loosen it by a maximum 1-quarter turn and check the
operation of the arm joint.
3. Place the O-ring and the ceiling cover over the support tube. Insert the support tube
Detailed view 2
into the anchor plate and install the locking bolt (Detailed view 2a) from top. Tighten
the screws on the anchor plate. Observe the correct order of the washer (2b) and
the serrated lock washer (2c). Now connect to the electrical power supply, as per the
wiring diagram (see sheet enclosed with the set of bolts). Slide the ceiling cover and
the O-ring to the anchor plate.
4. Head Assembly (see page 8)
Mounting steps
www.amico.com 7
Page 8
7. Assemblyand Installation MIRA 45Floor Stand
cInsert the support tube into the castor base and tighten the set-screws
(support disc, screws - 1xM8, 1 x M5 – and serrated washer).
dPlace the spring-loaded arm on the support tube and align the holes.
Attach the cable holder with the supplied screws and tighten.
eHead Assembly (seebelow)
f
7. Assemblyand Installation MIRA 45Floor Stand
Mounting steps
cInsert the support tube into the castor base and tighten the set-screws
(support disc, screws - 1xM8, 1 x M5 – and serrated washer).
dPlace the spring-loaded arm on the support tube and align the holes.
Attach the cable holder with the supplied screws and tighten.
eHead Assembly (seebelow)
8. Head Assembly
Match the plug- and socket connectors as shown in Fig c completely. The active parts has to be total covered. Align the hole on the end of the top arm with the hole on the limiter and slide the limiter into the top arm (see Figs. dand e). Insert and tighten the two set-screws to hold the head in place(see Fig. f).
c
d
e
f
7. Assemblyand Installation MIRA 45Floor Stand
Mounting steps
cInsert the support tube into the castor base and tighten the set-screws
(support disc, screws - 1xM8, 1 x M5 – and serrated washer).
dPlace the spring-loaded arm on the support tube and align the holes.
Attach the cable holder with the supplied screws and tighten.
eHead Assembly (seebelow)
8. Head Assembly
Match the plug- and socket connectors as shown in Fig c completely. The active parts has to be total covered. Align the hole on the end of the top arm with the hole on the limiter and slide the limiter into the top arm (see Figs. dand e). Insert and tighten the two set-screws to hold the head in place(see Fig. f).
Assembly and Installation MIRA 45 Floor Stand
1. Insert the support tube into the castor base and tighten the set-screws
(support disc, screws - 1 x M8, 1 x M5 – and serrated washer).
2. Place the spring-loaded arm on the support tube and align the holes.
Attach the cable holder with the supplied screws and tighten.
3. Head Assembly (see below)
Mounting steps
Head Assembly
Match the plug- and socket connectors as shown in Fig 1 completely. The active parts has to be total covered. Align the
hole on the end of the top arm with the hole on the limiter and slide the limiter into the top arm (see Figs. 2 and 3).
Insert and tighten the two set-screws to hold the head in place (see Fig. 4)
c
8 Amico Lighting Solutions
e
f
Page 9
Operating manual (GB)
9.PuttingintoOperation
Before placing the light into operation, the user has to check whether mains voltage and frequency specified on the rating plate are identical.
10. Care, Maintenance and Repair
Disconnect the light from the mains before carrying out anymaintenanceorrepairwork!This work must be carried out onlybya qualified electrician!
As replacement parts only use part approved by the manufacturer.
10.1.Regularchecks
9.PuttingintoOperation
Before placing the light into operation, the user has to check whether mains voltage and frequency specified on the rating plate are identical.
10. Care, Maintenance and Repair
Disconnect the light from the mains before carrying out anymaintenanceorrepairwork!This work must be carried out onlybya qualified electrician!
As replacement parts only use part approved by the manufacturer.
10.1.Regularchecks
The mains line must be checked minimum once a a year for damage (only MIRA 45Floor Stand). In case of damage the manufacturer must replace the defective mains line.
10.2. Adjustment of the counter-balance (Fig. c)
Figure c
The counter-balance arm will already have been factory set for best possible operation. Should adjustment become necessary: Set the spring tension as illustrated, and using a clearance of 4 mm.
10.3. Changingthe lamp
Note: Let the halogen lamp cool downbefore changing it!
1. Lift the hinged protective back cover of the head (see Fig. c)
2. The required Allen wrench is located inside the back cover (see Fig. d). Remove the lamp head retaining screw (see Fig.e)
3. Remove the cover ring and reflector
4. Change the halogen lamp (use a soft cloth and do not touch the glass surface of either the old or new lamp, see Fig. f)
5. Replace the reflector an cover ring. Replace an tighten the screws.
6. Replace the Allen wrench (see Fig, d)
Note: Only use lamp types approved of by the manufacturer (see ‚
Technical Data’ onpage 11).
c
9.PuttingintoOperation
Before placing the light into operation, the user has to check whether mains voltage and frequency specified on the rating plate are identical.
10. Care, Maintenance and Repair
Disconnect the light from the mains before carrying out anymaintenanceorrepairwork!This work must be carried out onlybya qualified electrician!
As replacement parts only use part approved by the manufacturer.
10.1.Regularchecks
The mains line must be checked minimum once a a year for damage (only MIRA 45Floor Stand). In case of damage the manufacturer must replace the defective mains line.
10.2. Adjustment of the counter-balance (Fig. c)
Figure c
The counter-balance arm will already have been factory set for best possible operation. Should adjustment become necessary: Set the spring tension as illustrated, and using a clearance of 4 mm.
10.3. Changingthe lamp
Note: Let the halogen lamp cool downbefore changing it!
1. Lift the hinged protective back cover of the head (see Fig. c)
2. The required Allen wrench is located inside the back cover (see Fig. d).
Remove the lamp head retaining screw (see Fig.e)
3. Remove the cover ring and reflector
4. Change the halogen lamp (use a soft cloth and do not touch the glass
surface of either the old or new lamp, see Fig. f)
5. Replace the reflector an cover ring. Replace an tighten the screws.
6. Replace the Allen wrench (see Fig, d)
Note: Only use lamp types approved of by the manufacturer
Putting into Operation
Operating manual (GB)
9.PuttingintoOperation
Before placing the light into operation, the user has to check whether mains voltage and frequency specified on the rating plate are identical.
10. Care, Maintenance and Repair
Disconnect the light from the mains before carrying out anymaintenanceorrepairwork!This work must be carried out onlybya qualified electrician!
As replacement parts only use part approved by the manufacturer.
10.1.Regularchecks
The mains line must be checked minimum once a a year for damage (only MIRA 45Floor Stand). In case of damage the manufacturer must replace the defective mains line.
10.2. Adjustment of the counter-balance (Fig. c)
The counter-balance arm will already have been factory set for best possible operation. Should adjustment become necessary: Set the spring tension as illustrated, and using a clearance of 4 mm.
10.3. Changingthe lamp
Note: Let the halogen lamp cool downbefore changing it!
Before placing the light into operation, the user has to check whether mains voltage and
frequency specied on the rating plate are identical.
Care, Maintenance and Repair
Disconnect the light from the mains before carrying out any maintenance or repair
work! This work must be carried out only by a qualied electrician!
As replacement parts only use part approved by the manufacturer.
Regular Checks
The mains line must be checked minimum once a year for damage (only MIRA 45 Floor
Stand). In case of damage the manufacturer must replace the defective mains line.
Figure c
c
Adjustment of the counter-balance (Fig. 1)
The counter-balance arm will already have been factory set for best possible operation.
Should adjustment become necessary: Set the spring tension as illustrated, and using a
clearance of 4 mm.
Changing the Lamp
Note: Let the halogen lamp cool down before changing it!
1. Lift the hinged protective back cover of the head (see Fig. 1)
2. The required Allen wrench is located inside the back cover (see Fig. 2). Remove the
lamp head retaining screw (see Fig.3)
3. Remove the cover ring and reector
4. Change the halogen lamp (use a soft cloth and do not touch the glass surface of either
the old or new lamp, see Fig. 4)
5. Replace the reector an cover ring. Replace an tighten the screws.
6. Replace the Allen wrench (see Fig. 2)
Note:Only use lamp types approved of by the manufacturer (see Technical Data on page
11)
d
ec
f
www.amico.com 9
Page 10
10.4. Troubleshooting
1. Check the on/off Switch
2. Check the electrical supply
3. Check the halogen lamp, change if necessary
4. Check all terminal connections in the fixture Also check the voltage on the connecting terminal.
10.5. Cleaning
Note: The periodical cleaning of the face-plate ensure a better light efficiency. Use a usual glass cleaner.
Troubleshooting, Cleaning and Disinfection
Troubleshooting
1. Check the on/o Switch
2. Check the electrical supply
3. Check the halogen lamp, change if necessary
4. Check all terminal connections in the xture Also check the voltage on the connecting terminal.
Cleaning
Note: The periodical cleaning of the face-plate ensure a better light eciency. Use a usual glass cleaner.
Do not use concentrated disinfectant or dissolver. For cleaning the outer surfaces, use a cloth moistened
with usual cleaner. Observe the compatibility with varnishes an plastics of the used cleaners.
Disinfection
According to instruction diluted brands can used for cleaning the outer surfaces:
• Lysoformin®
• Dismozon®
• Hexaquart® plus
• Sagrotan® – Rapid disinfection cleaner
Observe all applicable local regulations.
The disinfection cleaner are applied only for wipe disinfection. Spraying disinfection is not allowed.
Sterilization
The grip can be sterilized for 30 minutes at 120° and 1.05 bar.
10 Amico Lighting Solutions
Page 11
11. Technical Data
Electrical values:
Nominal voltage:
120 V ~
Frequency range
50/60 Hz
11. Technical Data
Electrical values:
Nominal voltage:
120 V ~
Frequency range
50/60 Hz
Power consumption:
50 W
Integrated electronic transformer
120 V / 12 V
Luminous values:
Central illuminance (0.8 m)
45’000 lux
Central illuminance (1.0 m)
≥ 40'000 lux
Light field diameter 0.8 m D10 ∅ = 15cmColour temperature
ca. 4000 K
Colour rendering index
Ra 90
Ambient conditions for transport, storage and operating:
Ambient temperature (transport and storage)
-20°C to +70°C
Ambient temperature (operating)
0°C to +35°C
relative humidity
max. 90%
Fitted with:
Halogen lamp
1 x 12 V / 50 W
Type
QT12 50 W
Classification:
Protection class (
MIRA 45Floor Stan
II
Protection class (MIRA 45Wall Mount, MIRA 45Single Ceiling, MIRA 45Double Ceiling)
I
Int. protection according to IEC 529
IP 20
Class I
Safety inspection according
EN 60601-1
IEC 601-1
UL 601-1
12. Disposal
At the end of its service life, the lamp and the halogen lamps must be disposed of in accordance with local regulations.
Technical Data and Disposal
Technical Data
Electrical values:
Nominal voltage: 120 V ~
Frequency range 50/60 Hz
Power consumption: 50 W
Integrated electronic transformer 120 V / 12 V
Luminous values:
Central illuminance (0.8 m) 45’000 lux
Central illuminance (1.0 m) ≥ 40’000 lux
Light eld diameter 0.8 m D10 Ø = 15 cm
Colour temperature ca. 4000 K
Colour rendering index Ra 90
Ambient conditions for transport, storage and operating:
Ambient temperature (transport and storage) -20°C to +70°C
Ambient temperature (operating) 0°C to +35°C
Relative humidity max. 90%
Fitted with:
Halogen lamp 1 x 12 V / 50 W
Type QT12 50 W
Classication:
Protection class (MIRA 45 Floor Stan II
Protection class (MIRA 45 Wall Mount, MIRA 45 Single Ceiling, MIRA 45 Double Ceiling) I
Int. protection according to IEC 529 IP 20
Rating according to 93/42 EWG - Appendix IX Class I
Safety inspection according EN 60601-1
IEC 601-1
UL 601-1
Disposal
At the end of its service life, the lamp and the halogen lamps must be disposed of in accordance with
local regulations.