employees and Agents will not be responsible for any loss, however arising, from the use of, or
reliance on, this information.
Legal Notice: Parts of this product are protected by patents.
Electromagnetic Compatibility (EMC)
This is a Class B product.
Manufacturer’s Declaration of Conformance
A Declaration of Conformity in accordance with the following EU standards has been made and is kept
on file at the address shown on the last page.
The manufacturer declares that the product supplied with this document is compliant
with the provisions of the EMC Directive 2014/30/EU, the Low Voltage Directive LVD
2006/95/EC and the CE Marking Regulation 768/2008/EC & Decision 765/2008.
This device complies with Part 15 of the FCC Rules.
Operation of this product is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may
cause undesired operation.
ICES-003
This Class B digital apparatus meets all requirements of the Canadian Interference causing equipment
regulations.
Cet appareil numérique de la Classe B Respecte toutes les exigences du Règlement sur le matérial
rouiller du Canada.
USER MANUAL AMG 9IM2X/9HM2X 2
1 : INTRODUCTION
Before You Begin
Read these instructions carefully before installing or operating this product.
Note: This equipment should be installed by a qualified service person and should conform to local
and national regulations.
This manual provides installation and operation information. To use this document you must have the
following minimum qualifications
A basic knowledge of Ethernet, Ethernet Switches and Layer2 networking.
A basic knowledge of electrical wiring and low-voltage electrical connection.
Intended Use
Use this product only for the purpose for which it was designed, as described in this manual.
Warning:
Improper use of this equipment can cause severe bodily injury or equipment damage
Environmental Conditions
Storage: -45° to +85° C. The switch should be allowed to acclimatize to its operational temperature
range before power is supplied. Additionally, if the switch is moved from a colder area to a warmer
area, precautions should be taken to ensure that condensation is prevented.
Operational: -40° to +74° C.
Customer Support
For assistance in installing, operating, maintaining and troubleshooting this product, please refer to
this document and any other documentation provided. If you still require assistance, please contact
AMG Systems at the address shown on the last page
9IM2X/9HM2X USER MANUAL 3
AMG SYSTEMS LTD.
Document
Rev No.
Change Description
Author
Date
2.0.0.5
Draft
M.I.Steval
22-04-2016
2.0.0.6
1. New non-TFTP s/w upgrade feature.
2. Updated screen-capture examples
M.I.Steval
16-06-2016
2.0.0.b7
Beta7 Release
M.I.Steval
01/07/2016
2.0.0.b8
1. Clarification of configuration in var sections
2. Added SFP transceivers section
M.I.Steval
13/07/2016
2.0.0.b9
1. Corrected rear panel DC power options
2. Clarification of configuration in various sections
3. IPv4 Default DHCP settings
4. Details of Syslog Traps and Messages
5. ECFM Module documentation added.
6. Updated EMC Directive Spec.
7. Static Unicast / Multicast Address added.
8. Updated LLDP section
M.I.Steval
08/09/2016
2.0.0
Release version
1. Management feature : additional user / password.
2. Updated screen captures VLANs, LLDP, RSTP
3. Updated Save and Restore section.
M.I.Steval
13/10/2016
2.1.0
Release version for 9IM2x/9HM2x platform
Provisional.
M.I.Steval
11/01/2017
2.1.1
Unreleased draft feature updates
M.I.Steval
23/02/2017
2.1.4
1. Additional Features :
DHCP Server
IGMP Snooping
Jumbo Frame Support
High Speed I/O
2. Updated Screenshots.
3. Added 240W info.
M.I.Steval
19/07/2017
2.1.4.1
1. Correction VLAN Chapter heading missing.
2. Minor corrections to RSTP & MSTP configuration.
3. Carifications in SNMP Trap Manager configuration.
Provider Backbone Bridging – Traffic Engineering Multiple Spanning Tree ID
PVID
Port VLAN ID
PVRST
Per VLAN Rapid Spanning Tree
QoS
Quality of Service
RADIUS
Remote Authentication Dial In User Service
RARP
Reverse Address Resolution Protocol
RDI
Remote Defect Indication
RIB
Routing Information Base
RIP
Routing Information Protocol
RM
Redundancy manager
RP
Rendezvous Point
RSTP
Rapid Spanning Tree Protocol
SA
Source-Active
SEM
State Event Machine
SFTP
SSH File Transfer Protocol
SHA
Security Hash Algorithm
SM
Sparse Mode
SMTP
Simple Mail Transfer Protocol
SNAP
Sub Network Access Protocol
SNMP
Simple Network Management Protocol
SNTP
Simple Network Time Protocol
SSH
Secure Shell
9IM2X/9HM2X USER MANUAL 17
AMG SYSTEMS LTD.
Acronym
Explanation
SSL
Secure Socket Layer
SST
Single Spanning Tree
STP
Spanning Tree Protocol
SVL
Shared VLAN Learning
S-VLAN
Service VLAN
TACACS
Terminal Access Controller Access Control System
TCP
Transmission Control Protocol
TCP/IP
Transmission Control Protocol/Internet Protocol
TELNET
Telecommunications Network
TFTP
Trivial File Transfer Protocol
TLV
Type, Length, Value
TTL
Time-To-Live
UDP
User Datagram Protocol
UNI
User Network Interface
URL
Uniform Resource Locator
UTC
Coordinated Universal Time
VC
Virtual Circuit
VID
VLAN ID
VLAN
Virtual LAN
WAN
Wide Area Network
USER MANUAL AMG 9IM2X/9HM2X 18
1 : INTRODUCTION
Chapter
1
Introduction
This user’s guide is targeted to provide information on installing, configuring
and maintaining the AMG 9IM2x/9HM2x Multi-service Ethernet switches.
AMG 9IM2x/9HM2x Multi-Service Ethernet Switch has all capabilities to
support ruggedized Layer2 Managed Ethernet functionality. In addition to
Layer2 & some Layer3 functionality, these products also support integration
of low-speed I/O, allowing Serial Ports, Alarm Contacts, Audio Devices and
Analogue Video to be directly connected to the switch, without requirement
for any additional hardware.
Historically, this requirement has been dealt with through the use of thirdparty serial port, audio, and Contact-closure I/O servers, resulting in a
disparate, multi-vendor product mix and corresponding issues with product
integration. AMG 9IM2x/9HM2x Multi-Service Ethernet switches eliminate all
these issues with a one-box solution. These switches offer a common web
management interface for configuration of all aspects of the device - Ethernet
as well as serial ports, audio ports and Alarm I/O.
The AMG 9IM2x/9HM2x management features are designed to minimize
administrative management effort, while enhancing and improving network
traffic control.
AMG 9IM2x/9HM2x supports easy management and configuration through
SNMP, CLI or WEB GUI.
9IM2X/9HM2X USER MANUAL 19
AMG SYSTEMS LTD.
Part numbers
Description
AMG9IM2-8G-2S
21hp : 8x RJ45 GbE + 2x SFP
GbE
AMG9IM2-4FH-1S-4S16C
14hp : 4x RJ45 FE + 1x SFP
GbE/FE + 4x Serial Data + 16
Contact Closures + PoE/+
AMG91IM2-20GH-5S-4S16C-P240
42hp : 20x RJ45 GbE + 5x SFP
GbE/FE + 4x Serial Data + 16
Contact Closures
1.1 AMG 9IM2x/9HM2x Models
This section describes different hardware configuration examples of AMG
9IM2x/9HM2x series products.
All systems are available as DIN Rail mounting units.
Table 1-1 : AMG9IM2x Model Examples
Front panels of this system are depicted as shown in following pages:
NOTE : Please see separate User Guide for AMG Video Encoder
USER MANUAL AMG 9IM2X/9HM2X 20
CHAPTER 1 : INTRODUCTION
1.2 AMG9IM2-8G-2S
21hp : 8x RJ45 GbE + 2x SFP GbE
Figure 1-1 : 9IM2-8G-2S
1.3 AMG91IM2-4FH-1S-4S16C
14hp : 4x FE (4 PoE+) + 4x serial + 16x contact closures + 1x SFP
GbE/FE
This section describes AMG 9IM2x/9HM2x hardware. It describes how the
different ports, LEDs and connectors are to be used.
AMG 9IM2x/9HM2x has ports for connectivity to different devices. These
ports can be categorized into 3 categories
Console port – RJ45 serial RS-232 data for access to CLI (Command Line)
interface.
Ethernet ports – used for Ethernet connectivity. These ports can be copper
ports or Transceiver ports. Copper ports can operate at speeds of
10/100/1000 Mbps. Transceiver ports can accommodate optical connectivity
through Fibre transceivers as well as copper connectivity through copper
transceivers.
I/O Ports – This product series has support for built-in I/O ports in order to
accommodate serial data ports, alarm contacts, audio devices and video
encoder ports without requirement for any additional hardware.
AMG 9IM2x/9HM2x has LEDs on the front panel to indicate status and
activities of different ports in the system.
Use the following hyperlinks to view the various hardware features:
Management Console Connections
Ethernet Connections
I/O Connections
Pin Layout of data connectors
Power Connector
Power over Ethernet
Ethernet Port LEDs
I/O Port LEDs
9IM2X/9HM2X USER MANUAL 23
AMG SYSTEMS LTD.
RJ45 Cable
Colour
T568B
AMG
RJ45
Pin No.
RJ45
RS232
Signal
RJ45
DCE Wire
Colour
DB9
RS232
Pin No.
PC
DTE
RS-232
Signal
White/Orange
1
n/c
Blue
1
DCD
Orange
2
Tx-OUT
Orange
2
Rx-IN
White/Green
3
Rx-IN
Black
3
Tx-OUT
Blue
4
n/c
Red
4
DTR
White/Blue
5
GND
Green
5
GND
Green
6
n/c
Yellow
6
DSR
White/Brown
7
n/c
Brown
7
RTS
Brown
8
n/c
White
8
CTS
2.1 Management Console
Console port – RJ45 serial RS-232 data for access to CLI (Command Line)
interface. Management of M-SES from PC using serial terminal application
such as PuTTY, Hyperterminal etc. is possible using RJ45 to DB9 Adaptor /
Cable provided.
Figure 2-1 : Console Adaptor / Cable
Console connections are provide using supplied AMG RJ45 to DB9 Adaptor.
This provides a direct connection to a PC’s DB9 serial port using a “straightthough” Ethernet patch cable.
Note. only DB9 pins 2,3,5 are actually used – but all wires are connected in
the adaptor as shown in the following table:
Table 2-1 : Console Port Connections
USER MANUAL AMG 9IM2X/9HM2X 24
CHAPTER 2 : HARDWARE DESCRIPTION
AMG Part
Numbers
Ports
Supported
Fibre
Type
Wavelength
Tx (nm)
Speed
(Mbps)
Max
distance
S18074
F1-F6, FA-FC
dual fibre
1310
100
20km
S18170
F1-F6, FA-FC
dual fibre
1310
100
40km
S18056
F1-F6, FA-FC
dual fibre
1310
1000
20km
S18057
F1-F6, FA-FC
dual fibre
1550
1000
40km
S18054/55
F1-F6, FA-FC
single fibre
1310/1550
1000
40km
2.2 Ethernet Connections
Ports P1 to P24 have RJ45 connectors providing 10/100/1000Mbps.
Figure 2-2 : RJ45 Ethernet Ports
Ports F1 to F6 and FA to FC are SFP transceiver ports for use with fibre or
copper SFPs. For further details see tables below.
Figure 2-3 : SFP Transceiver Ports
Singlemode Fibre
Table 2-2 : Singlemode Fibre SFPs
9IM2X/9HM2X USER MANUAL 25
AMG SYSTEMS LTD.
AMG Part
Numbers
Ports
Supported
Fibre
Type
Wavelength
Tx (nm)
Speed
(Mbps)
Max
distance
S18082
F1-F6, FA-FC
dual fibre
1310
100
2km
S18095/96
F1-F6, FA-FC
single fibre
1550/1310
100
2km
S18200/201
F1-F6, FA-FC
single fibre
1550/1310
1000
500m
AMG Part
Numbers
Ports
Supported
Connector
Type
Speed
(Mbps)
Max
distance
S24010
F1-F6, FA-FC
RJ45
10/100/1000
100m
S24010
F1-F6, FA-FC
RJ45
1000
100m
Multi-Mode Fibre
Table 2-3 : Multi-mode Fibre SFPs
Copper
Table 2-4 : Copper SFPs
Note: for unsupported transceivers AMG 9IM2x/9HM2x Management
Interface gives the provision to configure the speed manually.
2.3 I/O Connections
For low speed serial data ports (RS-232/RS-485/RS-422) and other I/O, the
device provides up to 8x 5-way connectors depending on the model variant.
Each connector is a Phoenix style connector providing a total of 4x BiDirectional low speed data ports D1-D4 and 16x configurable contact closure
ports C1-C16.
Figure 2-4 : I/O Connections
USER MANUAL AMG 9IM2X/9HM2X 26
CHAPTER 2 : HARDWARE DESCRIPTION
Data
Port
Pin
No.
RS-422
RS-485
RS-232
D1 1 D1 Data OUT- (B)
D1 Data IN/OUT- (B)
D1 Data OUT (Tx)
D1 2 D1 Data OUT+ (A)
D1 Data IN/OUT+ (A)
D1 3 GND
GND
GND
D1 4 D1 Data IN- (B)
D1 5 D1 Data IN+ (A)
D1 Data IN (Rx)
Data
Port
Pin
No.
RS-422
RS-485
RS-232
D2 1 D2 Data OUT- (B)
D2 Data IN/OUT- (B)
D2 Data OUT (Tx)
D2 2 D2 Data OUT+ (A)
D2 Data IN/OUT+ (A)
D2 3 GND
GND
GND
D2 4 D2 Data IN- (B)
D2 5 D2 Data IN+ (A)
D2 Data IN (Rx)
Data
Port
Pin
No.
RS-422
RS-485
RS-232
D3 1 D3 Data OUT- (B)
D3 Data IN/OUT- (B)
D3 Data OUT (Tx)
D3 2 D3 Data OUT+ (A)
D3 Data IN/OUT+ (A)
D3 3 GND
GND
GND
D3 4 D3 Data IN- (B)
D3 5 D3 Data IN+ (A)
D3 Data IN (Rx)
Data
Port
Pin
No.
RS-422
RS-485
RS-232
D4 1 D4 Data OUT- (B)
D4 Data IN/OUT- (B)
D4 Data OUT (Tx)
D4 2 D4 Data OUT+ (A)
D4 Data IN/OUT+ (A)
D4 3 GND
GND
GND
D4 4 D4 Data IN- (B)
D4 5 D4 Data IN+ (A)
D4 Data IN (Rx)
2.4 Pin Layout of I/O Connectors
Serial Data Ports D1-D4
Note: (A) or (B) in brackets in the tables below refer to RS-485 / RS-422 data specification
Table 2-5 : Serial Data I/O Connections
9IM2X/9HM2X USER MANUAL 27
AMG SYSTEMS LTD.
Pin
name
Pin
name
C1
C5
C2
C6
GND
GND
C3
C7
C4
C8
C9
C13
C10
C14
GND
GND
C11
C15
C12
C16
Contact Closure ports C1-C16
The AMG 9IM2x/9HM2x provides 16 contact closure inputs / outputs. Each contact closure may be
configured as either an intput (IN) or an output (OUT).
Each CC IN is a digital ON/OFF input typically used to detect contact closure status. The detection circuit
is via an internal 8.2kΩ series resistor with a 47kΩ pull-up resistor to the internal +3V3 supply.
LOW level : input voltage < 0.5V or a low impedance (0Ω to 1kΩ) short circuit to GND
HIGH level : input voltage > +3V3 to +24Vdc or an open circuit.
Each CC OUT is a digital ON/OFF output (current sink) typically used to convey contact closure status.
Each output circuit is an open drain power MOSFETwithseries 4.7Ω resistor and has a maximum rated
continuous load current of 250mA, and maximum input voltage of +24Vdc.
Table 2-6 : Contact Closure I/O Connections
2.5 Power Connector
Power Connectors used in AMG 9IM2x/9HM2x depends on the device
variant and Power over Ethernet (POE) support on the device.
+48V DC to +56V DC – For POE variant.
+12V DC to +24V DC – For non-POE variant.
Please note : Total system load should not exceed 240W.
USER MANUAL AMG 9IM2X/9HM2X 28
CHAPTER 2 : HARDWARE DESCRIPTION
Figure 2-5 : PoE Power Connections
Figure 2-6 : Non PoE Power Connections
2.6 Power over Ethernet
Power over Ethernet (PoE) is a provision to power over Ethernet cables. So,
an Ethernet cables carries both data and current together to operate devices
like IP cameras. This is very helpful to install devices in remote places such
9IM2X/9HM2X USER MANUAL 29
AMG SYSTEMS LTD.
Parameter
PoE
PoE+
PoE-U
PoH
Input Voltage
48-50V
56-60V
56-60V
56-60V
Output Power
15W
25W
60W
90W
Output Voltage
44-48V
52-56V
52-56V
52-56V
as ceilings, where it is hard to find power outlets. Only smaller devices can
be powered using the PoE, as it carries limited power over the Ethernet.
1. The original IEEE 802.3af-2003 PoE standard provides up to 15.4 W of
DC power (minimum 44 V DC and 350 mA) to each device. Only 12.95 W is
assured to be available at the powered device as some power is dissipated
in the cable.
2. The updated IEEE 802.3at-2009 PoE standard also known as PoE+ or
PoE plus, provides up to 25.5 W of power per port/device.
3. PoE-U / PoH non-ratified standards provide up to 60W / 90W of power per
port/device.
Here are POE specifications of AMG 9IM2x/9HM2x per port :
Table 2-7 : POE Specifications
Please note : Total system load should not exceed 240W.
2.7 Ethernet Port LEDs
Each non-transceiver Ethernet port has two LEDs - Link/Activity and PoE
power output status. These are are situated on the left side of each RJ45
port-connector as depicted below:
Figure 2-7 : Ethernet Port LEDs
USER MANUAL AMG 9IM2X/9HM2X 30
Loading...
+ 279 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.