Amerikooler 24DT Installation Manual

WEISS INSTRUMENTS
24DT
DIGITALTHERMOMETER
INSTALLATION AND OPERATINGINSTRUCTIONS
PLEASE READ THIS MANUAL FULLY!
device for easy and quick reference.
1. GENERAL DESCRIPTION
The 24DT is an electronic digital thermometer which displays the current temperature and also logs the maximum and minimum temperatures experienced. With the use of an Optional momentary switch the min. / max. Temperatures can be displayed at the touch of a button and reset if required. (Switch sold separately) A 9 Volt battery can supply backup power for temperature readings when there is a blackout. (Battery bracket and harness sold separately)
2. INSTALLATION
The instrument is equipped with fast-on type spade terminals with probe connections separated from the power supply connections. To install the instrument proceed as follow:
1. Attach .250 inch Fast-on connectors to the wires for the interior light and the wires connecting the switches.
2. Wire the switch according to the drawing Fig. 1.
3. Place the probe where it has to measure the temperature. Be sure to leave slack so as to have some strain relief. Probe bulb should have the end up vertically or on at least a slight angle to try to prevent water intrusion into the sensor. Were a sharp bend is required try to loop the probe wire in a 1 ½ “circle.
4. Connect the probe terminals to the two small (.110 inch) fast­on connectors as indicated.
5. Connect the power supply cables to the large (.250”) fast­ons. (N or NEUTRAL) to the fast-on on the left and (L or HOT) to the fast-on on the right. SEE FIG. 2
6. There should be .63mA fuse on the Line.
7. If using the optional 9V battery back up install it on the connectors at the top left of the thermometer.
3. DRAWINGS
Fig.1
Fig. 2
N L
NOTE: POWER SUPPLY AS STATED ON UNIT
LABEL!
4. ALARM DISPLAY
MESSAGE CAUSE PO P1
OPEN PROBE OR SWITCH CLOSED NO PROBE CONNECTED
SAFETY PRECAUTIONS
Always ensure that the probe is connected to the instrument
before the power supply is connected and turned ON.
Check the supply voltage is correct before connecting the
instrument. (12V, 120V, 230V) (N or NEUTRAL) to the fast-on on the left and (L or HOT) to the fast-on on the right. SEE FIG. 2
The probe is double insulated for safety on models with 110V
and 230V power supply.
The instrument is designed for panel mounting and electrical
connections must be positioned inside a properly protected board/panel.
Do not expose to water or moisture: use the instrument only
within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent the formation of condensation.
Warning: disconnect all electrical connections before any kind of
maintenance.
The instrument shall never be opened. In case of failure or faulty operation send the instrument back to
the distributor or Weiss Instruments (see address) with a detailed description of the fault.
Be sure that the wires for probes and for the power supply are
separated and far enough from each other, without crossing and coiling.